• 38kV/400A RCW-F38N MV outdoor vacuum recloser
38kV/400A RCW-F38N MV outdoor vacuum recloser
$5000.00
Model
RCW-F38N/1250-25
RCW-F38N/800-20
RCW-F38N/630-16
RCW-F38N/400-12.5
Basic info
Brand ROCKWILL
Model NO. 38kV/400A RCW-F38N MV outdoor vacuum recloser
Rated voltage 38kV
Rated normal current 800A
Rated short circuit breaking current 20kA
Power frequency withstand voltage 85kV/min
Rated lightning impulse voltage 185kV
manual closing No
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-linemonitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters:

image.png

image.png

External dimensions:

企业微信截图_17104715299878.png


Environmental requirement:

image.png

Product show:

正方形环氧树脂永磁带手合.png

What are the mechanical failures of outdoor vacuum reclosers?

Operating Mechanism Faults:

Spring-Operated Mechanism:

  • Spring Fatigue: Spring fatigue is a common issue. If the spring remains compressed for a long time or is frequently operated, it may lose its elasticity, causing the closing speed to slow down or the closing position to be inaccurate. Additionally, mechanical transmission components of the spring-operated mechanism, such as connecting rods and toggle arms, can wear out, deform, or become stuck, affecting the accuracy and reliability of the opening and closing operations.

Permanent Magnet-Operated Mechanism:

  • Magnet Demagnetization: Demagnetization of the permanent magnet is a potential fault in permanent magnet-operated mechanisms. High-temperature environments, strong vibrations, or prolonged exposure to high currents can weaken the magnetic properties of the permanent magnet, affecting the performance of the operating mechanism. Furthermore, faults in the control circuit of the permanent magnet-operated mechanism, such as capacitor aging or electronic component failure, can also lead to abnormal opening and closing operations.

Transmission Component Faults:

  • Loose or Detached Connecting Rods: In outdoor vacuum reclosers, the transmission connecting rods may loosen or even detach over time due to vibration, corrosion, or other factors. This can prevent the opening and closing actions from being transmitted properly, causing the recloser to fail to operate correctly.

  • Wear or Breakage of Pivot Pins: Pivot pins can wear out during rotation. Severe wear can increase the clearance between transmission components, affecting the precision of the opening and closing actions. If a pivot pin breaks, it can directly interrupt the transmission chain of the recloser, preventing it from performing opening and closing operations.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Photovoltaic Grid-Connection and Transformer Specification Selection
Photovoltaic Grid-Connection and Transformer Specification Selection
In grid-connected photovoltaic (PV) power generation systems, the step-up transformer is a critical component. Optimizing transformer selection to minimize inherent losses and enhance efficiency is essential for improving overall system performance. This article outlines key considerations for proper step-up transformer selection in PV systems.Transformer Capacity SelectionThe required transformer capacity is calculated as: Apparent Power = Active Power / Power Factor. Power factor requirements
Edwiin
08/05/2025
The significance and functions of primary, secondary and tertiary distribution boxes
The significance and functions of primary, secondary and tertiary distribution boxes
In a newly constructed residential area, a 10kV power line is introduced into the substation. After stepping down the voltage through the transformer's low-voltage side (0.4kV), power distribution is achieved through three levels of distribution boxes: the main distribution board, secondary distribution boards, and tertiary distribution boards.Main Distribution BoardServes as the primary distribution point for the entire project, directly connected to the transformer providing 0.4kV power.Does n
Rockwell
08/05/2025
What are the common fault analyses and preventive measures for power capacitors?
What are the common fault analyses and preventive measures for power capacitors?
1 Failure Mechanisms of Power CapacitorsA power capacitor primarily consists of a housing, capacitor core, insulating medium, and terminal structure. The housing is typically made of thin steel or stainless steel, with bushings welded to the cover. The capacitor core is wound from polypropylene film and aluminum foil (electrodes), and the interior of the housing is filled with liquid dielectric for insulation and heat dissipation.As a fully sealed device, common failure types of power capacitors
Leon
08/05/2025
What does the optimization of reactive power compensation technology in power capacitors involve?
What does the optimization of reactive power compensation technology in power capacitors involve?
1 Overview of Reactive Power Compensation Technology1.1 Role of Reactive Power Compensation TechnologyReactive power compensation technology is one of the widely used techniques in power systems and electrical grids. It is primarily employed to improve power factor, reduce line losses, enhance power quality, and increase the transmission capacity and stability of the grid. This ensures that power equipment operates in a more stable and reliable environment, while also boosting the grid’s a
Echo
08/05/2025
What should be noted in the maintenance and management of power capacitors?
What should be noted in the maintenance and management of power capacitors?
Operation and Maintenance Guidelines for Power CapacitorsPower capacitors are static reactive power compensation devices primarily used to supply reactive power to electrical systems and improve power factor. By implementing local reactive power compensation, they reduce transmission line current, minimize line power losses and voltage drops, and contribute significantly to improved power quality and higher equipment utilization.The following outlines key aspects of power capacitor operation and
Felix Spark
08/05/2025
Performance Degradation and Life Prediction of Power Capacitors in High-Temperature Environments
Performance Degradation and Life Prediction of Power Capacitors in High-Temperature Environments
Performance Degradation Characteristics and Life Prediction of Power Capacitors under High-Temperature ConditionsWith the continuous expansion of power systems and increasing load demands, the operating environment for electrical equipment has become increasingly complex. Rising ambient temperature has emerged as a key factor affecting the reliable operation of power capacitors. As critical components in power transmission and distribution systems, the performance degradation of power capacitors
Oliver Watts
08/05/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!