36kV 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker(VCB)

  • 36kV 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker(VCB)

Key attributes

Brand ROCKWILL
Model NO. 36kV 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker(VCB)
Rated voltage 36kV
Rated normal current 2000A
Rated frequency 50/60Hz
Series NVBOA

Product descriptions from the supplier

Description

Description

The Dry Air Insulated Dead Tank VCB was born of superb technology and abundant production experience of Meidensha Corporation.It is a circuit breaker employing vacuum interrupters and dry air for insulation. In order to use no SF6, which is global warming gas, there is no fear to decomposition of gas due to current interruption. It is therefore a highly reliable and high-performance circuit breaker.

Feature

Dead Tank Type VCB optimized for green procurement. It uses dry air for insulation in place of the SF6 which is specified as a greenhouse gas. Our basic design concept is to realize the environmental factors in design (The 3Rs (Reduce, Reuse, and Recycle) + LS (Longuse & Separable)) and life-cycle cost (LCC) reduction as basic concepts.

  • Contribution to global warming prevention

Dry air insulation are employed instead of SF6 gas insulation. GWP (Global Warning Potential) of SF6 is 23,900.

  • Excellent breaking performance

Since each current breaking section employs a vacuum interrupter, insulation recovery characteristics are excellent. It exhibits superb characteristics in cases of short-circuit interruption and short line fault interruption.

  • Sucient capability against multiple strokes and evolving faults

Since the vacuum interrupters used are of completely self-arc-diusion type, this circuit breaker is the only unit that is capable of disposing of multiple strokes and evolving fault currents.

  • Reduction of maintenance labor

Use of vacuum interrupters in the current breaking sections eliminates requirements of inspection for these sections. Therefore, man-hours can be saved for maintenance and inspection.

Type and Ratings

Specifications

Rated voltage (kV)

36

72.5

Withstand
voltage

1 min power frequency (kV rms)

70

140

1.2x50μs impulse (kV peak)

200

350

Rated frequency (Hz)

50/60

Rated normal current (A)

2000

2000/3150

Rated short circuit breaker current (kA)

31.5

40

Rated transient recovery voltage 

Rate of rise

(kV/μs))

1.19

1.47

First pole to clear factor

1.5

Rated short circuit making current (kA)

82

104

Rated short time current (kA)

31.5 (3s)

40 (3s)

Rated breaking time (cycle)

3

Rated opening time (s)

0.033

0.03

Make time with no load (s)

0.05

0.10

Operating duty

O-0.3s-CO-15s-CO

Closing control voltage (Vdc)

48, 100, 110, 125, 250

Rated tripping voltage (Vdc)

48, 100, 110, 125, 250

Supply voltage for

charging motor

(Vdc)

48, 100, 110, 125, 250

(Vac)

60, 120, 240

Rated dry-air pressure

0.5MPa-g (at 20℃ )

Closing operation system

Spring

Tripping control system

Spring

Applicable standard

IEC 62271-100-2008, ANSI/IEEE C37.06-2009

Construction

Overall construction

For each phase, a current breaking vacuum interrupter is accommodated in the grounded tank. The operation system is such that closing and tripping are effected by spring force.The operating mechanism and 3-phase interlinkage are assembled on a common base, which is installed on the frame legs.

Internal construction

The overall structure is composed mainly of grounded tank, vacuum interrupters (VI), insulating rods, bushings and main circuit terminals. Each grounded tank is filled with dry air maintained at a rated pressure of 0.5MPa-g (20℃).

Internal construction of vacuum circuit breaker

Dry air system

Outline drawing

Dimensions (72.5kV)

Dimensions (36kV)

Standard connection diagram

Performance

Performance of the circuit breaker has been designed in accordance with ANSI and IEC standard, and verified by type test. All products are shipped after confirmation of various performances by acceptance test based on these standards.

  • Withstand voltage characteristics :Performance of withstand voltage is assured at the specified dry air pressure. Even though the dry air pressure has been lowered to the alarming level, the required insulation level can be assured.In addition, even though this pressure lowers to the atmosphericpressure, the circuit breaker withstands the rated voltage.

  • Current passing performance :Since the main contacts are located under vacuum, their surfaces are never oxidized and current passing performance is therefore stabilized. In the closing mode of circuit breaker, a pressing force is exerted between main contacts by the effect of pressing spring and sufficient tolerance is assured against closing current and short-time current.

  • Mechanical life :Due to adoption of simplified operating mechanism, switching characteristics are extremely stabilized. Frequent switching performance has also been verified through continuous mechanical switching test by repeating switching operations more than 10,000 times.

  • Electrical life :Since current breaking is performed in the vacuum interrupter,arcing energy generated during current interruption is extremely low and contact erosion is minimal. This implies long contact life.Load current switching : 10,000 times

  • Rated breaking current switching : 20 times

Documentation Resource Library
Restricted
Dead Tank Circuit Breakers Catalog
Catalogue
English
Consulting
Consulting
FAQ for
Q: What is the difference between vacuum circuit breaker and SF6 circuit breaker?
A:
  1. Their core difference is arc-extinguishing media: Vacuum breakers use high vacuum (10⁻⁴~10⁻⁶Pa) for insulation and arc extinction; SF₆ breakers rely on SF₆ gas, which adsorbs electrons well to quench arcs.
  2. In voltage adaptation: Vacuum breakers fit medium-low voltages (10kV, 35kV; some up to 110kV), rarely 220kV+. SF₆ breakers suit high-ultra high voltages (110kV~1000kV), mainstream for ultra-high voltage grids.
  3. For performance: Vacuum breakers extinguish arcs fast (<10ms), have 63kA~125kA breaking capacity, suit frequent use (e.g., power distribution) with long life (>10,000 cycles). SF₆ breakers excel in stable large/inductive current breaking but work less frequently, needing insulation recovery time post-extinction.
  4. Compared to SF6 gas circuit breakers, vacuum circuit breakers can achieve zero greenhouse gas emissions and are more environmentally friendly because the arc extinguishing device does not contain any gas
Q: What are the structural characteristics of the tank circuit breaker?
A:

Integral Tank Structure:

  • Integral Tank Structure: The breaker's arc quenching chamber, insulating medium, and related components are sealed within a metal tank filled with an insulating gas (such as sulfur hexafluoride) or insulating oil. This forms a relatively independent and sealed space, effectively preventing external environmental factors from affecting the internal components. This design enhances the insulation performance and reliability of the equipment, making it suitable for various harsh outdoor environments.

Arc Quenching Chamber Layout:

  • Arc Quenching Chamber Layout: The arc quenching chamber is typically installed inside the tank. Its structure is designed to be compact, enabling efficient arc quenching within a limited space. Depending on different arc quenching principles and technologies, the specific construction of the arc quenching chamber may vary, but generally includes key components such as contacts, nozzles, and insulating materials. These components work together to ensure that the arc is quickly and effectively extinguished when the breaker interrupts the current.

Operating Mechanism:

  • Operating Mechanism: Common operating mechanisms include spring-operated mechanisms and hydraulic-operated mechanisms.

  • Spring-Operated Mechanism: This type of mechanism is simple in structure, highly reliable, and easy to maintain. It drives the opening and closing operations of the breaker through the energy storage and release of springs.

  • Hydraulic-Operated Mechanism: This mechanism offers advantages such as high output power and smooth operation, making it suitable for high-voltage and high-current class breakers.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • A Brief Discussion on the Issues of Converting Reclosers into Outdoor Vacuum Circuit Breakers for Use
    The rural power grid transformation plays an important role in reducing rural electricity tariffs and accelerating rural economic development. Recently, the author participated in the design of several small-scale rural power grid transformation projects or conventional substations. In rural power grid substations, conventional 10kV systems mostly adopt 10kV outdoor auto circuit vacuum reclosers.To save investment, we adopted a scheme in the transformation that removes the control unit of the 10
    12/12/2025
  • A Brief Analysis of Automatic Circuit Recloser in Distribution Feeder Automation
    An Automatic Circuit Recloser is a high-voltage switching device with built-in control (it inherently possesses fault current detection, operation sequence control, and execution functions without requiring additional relay protection or operating devices) and protective capabilities. It can automatically detect the current and voltage in its circuit, automatically interrupt fault currents according to inverse-time protection characteristics during faults, and perform multiple reclosures accordi
    12/12/2025
  • Recloser Controllers: Key to Smart Grid Reliability
    Lightning strikes, fallen tree branches, and even Mylar balloons are enough to interrupt current flow on power lines. That’s why utility companies prevent outages by equipping their overhead distribution systems with reliable recloser controllers.In any smart grid environment, recloser controllers play a critical role in detecting and interrupting transient faults. Although many short circuits on overhead lines can resolve themselves, reclosers help improve service continuity by automatically re
    12/11/2025
  • Application of Fault Diagnosis Technology for 15kV Outdoor Vacuum Automatic Circuit Reclosers
    According to statistics, the vast majority of faults on overhead power lines are transient, with permanent faults accounting for less than 10%. Currently, medium-voltage (MV) distribution networks commonly employ 15 kV outdoor vacuum automatic circuit reclosers in coordination with sectionalizers. This setup enables rapid restoration of power supply after transient faults and isolates faulty line segments in the event of permanent faults. Therefore, it is essential to monitor the operational sta
    12/11/2025
  • Application of 10kV Reclosers and Sectionalizers in Rural Distribution Networks
    1 Current Grid StatusWith the continuous deepening of rural power grid transformation, the health level of rural grid equipment is constantly improving, and power supply reliability basically meets user needs. However, regarding the current grid status, due to funding constraints, ring networks have not been implemented, dual power supplies are unavailable, and lines adopt a single radial tree-like power supply method. This resembles a tree trunk with many branches—meaning the lines have numerou
    12/11/2025
  • What’s the Difference Between a Recloser and a Pole-Mounted Breaker?
    Many people have asked me: “What’s the difference between a recloser and a pole-mounted circuit breaker?” It’s hard to explain in one sentence, so I’ve written this article to clarify. In fact, reclosers and pole-mounted circuit breakers serve very similar purposes—they are both used for control, protection, and monitoring on outdoor overhead distribution lines. However, there are significant differences in the details. Let’s examine them one by one.1.Different MarketsThis may be the biggest dis
    11/19/2025

Related Solutions

  • High-Voltage SF6 Dead Tank Circuit Breaker Solution for Nigeria Power Grid
    1. Project BackgroundAs Africa&rsquo;s most populous nation, Nigeria&rsquo;s power grid has long faced challenges including unstable electricity supply, aging infrastructure, and poor environmental adaptability.In its high-voltage transmission and distribution networks, traditional oil circuit breakers struggle to meet growing demand due to frequent maintenance and vulnerability to humid climates (e.g., reduced insulation performance during rainy seasons).International case studies, such
    05/24/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.