• Photovoltaic grid-connected isolation transformer
Photovoltaic grid-connected isolation transformer
discuss personally
Model
SGG-220kVA
SGG-180kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic grid-connected isolation transformer
Rated frequency 50/60Hz
Rated capacity 220kVA
Series SGG
Product Detail

Product Overview:

Photovoltaic power generation inverter isolation transformers play a critical role in systems that harness solar energy via the photovoltaic effect at semiconductor interfaces, where solar cells serve as the core components. These cells are encapsulated and connected in series to form large-area modules, which, when integrated with power controllers, constitute a complete photovoltaic power generation device.

Designed primarily for solar inverter systems, photovoltaic transformers require high-efficiency performance to compensate for inherent energy conversion losses in photovoltaic setups. Their grid-side wiring configurations, such as Dyn11 and YD5 phase shift transformers with 120° phase displacement, ensure stable grid interconnection. To minimize no-load energy losses, these isolation transformers are typically operated during daylight hours and shut down at night.

Below are reference parameters for three-phase photovoltaic transformers:

Key Features:

  • Electrical Safety Isolation:Designed to achieve complete electrical separation between the photovoltaic system and the grid, preventing direct current (DC) leakage and reducing risks of electric shock. It blocks grid-borne harmonics and surges, ensuring clean power transmission.

  • Efficient Grid Compatibility:Supports standard grid connection configurations (e.g., Dyn11, YD5 with 120° phase shift) to match grid voltage and frequency requirements. Enables stable power inversion from DC (solar panels) to AC (grid), with conversion efficiency ≥98% to minimize energy loss.

  • Harmonic Suppression & Waveform Purity:Integrates low-loss core materials (e.g., oriented silicon steel) and foil winding technology to suppress 3rd harmonic distortion and maintain sine-wave output. Ensures compliance with grid power quality standards (e.g., IEEE 519) for reliable grid interconnection.

  • Adaptive Operation & Energy Savings:Features automatic daytime activation and nighttime shutdown to eliminate no-load losses. Suitable for off-grid/on-grid systems, with customizable capacity (5kVA–1000kVA) to match solar array scales.

  • Robust Environmental Adaptability:Constructed with weather-resistant enclosures (e.g., 304 stainless steel) for outdoor installations, resisting humidity, temperature fluctuations, and corrosion. Dry-type air cooling design ensures maintenance-free operation in harsh environments.

  • Customizable Design Flexibility:Supports voltage customization (input/output: 220V–1140V) and insulation classes (B/F/H) for diverse project needs. Compact structure fits limited space in solar power stations, with optional IP certifications for enhanced protection.

Technical data:

Conditions of Use. Working environment temperature: 15~+50℃

Operating ambient temperature:20—90%RH

Atmospheric pressure in the working environment:860 hpa---1060 hp2

Storage/transport temperature:20℃-- +55℃

Main technical features:

Rated capacity:5KVA—1000KVA

Input Voltage: Rated voltage 270V or 315V

Input current by actual voltage

Output voltage: Rated voltage: 380V or 400V

The output current is based on the actual voltage

Connection mode :dyn11

Efficiency :≤98.5%

Frequency: 50HZ/60HZ

Insulation resistance :25A less than 500MΩ

Induction withstand voltage :125HZ/800y/60

Insulation Chip Class :H (Temperature Resistance 180 °C)

Noise :≤30dB)

Temperature rise: ≤ allows for a temperature rise of 115k

Impedance Voltage Drop :≤4%

Structure: Forced air cooling, waiting for the temperature controller, according to customer requirements, reach a certain temperature, the fan will be automatically opened.

Degree of protection :IP00

Anti-interference mode: copper foil isolation shielding grounding:

Waveform Distortion No additional waveform distortion.

Electrical strength: Power frequency sinusoidal voltage 3000V, which lasts for one minute, without breakdown and flashover

Insulation resistance (input and output to ground) Test voltage at least 1000V DC insulation resistance greater than 1000MΩ

Overload capacity Twice the rated current for one minute.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Transformer operation and maintenance
Transformer operation and maintenance
Transformer Operating TemperatureDuring operation, transformers generate copper losses and iron losses, both of which are converted into heat, causing the transformer’s temperature to rise. Most transformers in China use Class A insulation. Due to heat transfer characteristics, significant temperature differences exist between different components during operation: winding temperature is the highest, followed by the core, and then the temperature of the insulating oil (with upper-layer oil being
Encyclopedia
07/31/2025
What Is An Inverter-integrated Transformer?
What Is An Inverter-integrated Transformer?
An inverter-integrated transformer is a power conversion device that combines the functions of an inverter and a transformer into a single unit. Widely utilized in renewable energy systems such as solar photovoltaic (PV) and wind power generation, its primary role is to convert direct current (DC) to alternating current (AC) while adjusting voltage levels (stepping up or down) via the transformer, ensuring compatibility with grid requirements or specific load demands.1. Basic Functions and Opera
Vziman
07/31/2025
Estimation of capacitive current
Estimation of capacitive current
The capacitive current is mainly determined by the length of the feeder, the cross-sectional area of the conductor, the dielectric constant, the height above the ground, and the rated voltage. The specific estimation methods are as follows:Estimation of capacitive current of overhead lines: For overhead lines of 3 - 35 kV, the capacitance per phase to ground is usually 5000 - 6000 pF/km. Based on this, the value of the single-phase grounding capacitive current per kilometer for lines of differen
Leon
07/31/2025
What are the technical characteristics of hydrogen-cooled power transformer technology?
What are the technical characteristics of hydrogen-cooled power transformer technology?
Power transformers are pivotal components in electrical grids, tasked with voltage conversion to enable efficient electricity transmission and distribution. As global energy demands surge and grid architectures grow increasingly complex, there is an urgent need for advanced transformer technologies that enhance efficiency, minimize environmental impact, and ensure operational reliability. Among emerging innovations, hydrogen-cooled power transformer technology has emerged as a particularly promi
Edwiin
07/31/2025
What are the basic knowledge points about transformer bushings?
What are the basic knowledge points about transformer bushings?
1. Functions of Transformer BushingsThe core function of transformer bushings is to lead the coil leads out to the external environment. They serve both as insulating components between the leads and the oil tank and as fixing devices for the leads.During the operation of a transformer, bushings continuously carry load currents and, in the event of an external short circuit, withstand short-circuit currents. Therefore, transformer bushings must meet the following requirements:Possess specified e
Rockwell
07/31/2025
What are the application scenarios of power transformers with a rating above 10kV?
What are the application scenarios of power transformers with a rating above 10kV?
High - voltage power transformers (above 10 kV) are extensively applied in various sectors, spanning residential and industrial fields. The following is a detailed overview of their main application scenarios and technical characteristics:1. Urban and Civil Applications1.1 Residential Communities and Commercial CentersThe 10 kV - rated combination transformer, favored for its compact size and fully sealed structure, is widely used in new residential complexes, shopping centers, and high - rise b
Vziman
07/31/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.