• Photovoltaic Auxiliary Energy Storage Transformer
Photovoltaic Auxiliary Energy Storage Transformer
discuss personally
Model
SGG-200kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic Auxiliary Energy Storage Transformer
Rated frequency 50/60Hz
Rated capacity 200kVA
Series SGG
Product Detail

Product Overview:

The grid-connected energy storage auxiliary isolation transformer for photovoltaic power generation is generally used for solar inversion, with common voltages including 800V to 400V, 380V, 690V to 400V, 540V to 400V, etc. (customizable as required); due to the low photoelectric efficiency of photovoltaic silicon panels, the transformer is specially required to have high efficiency. The photovoltaic isolation transformer is equipped with a microcomputer intelligent time controller to set daytime operation and nighttime stop for reducing no-load power loss, a temperature controller to real-timely monitor the operating temperature of the transformer, control the start and stop of the cooling fan, and automatically stop and disconnect the transformer when the operating temperature is too high to reach the set critical temperature for protecting the safety of the transformer body, a self-reset overvoltage and undervoltage protector to prevent islanding operation, a surge protector to effectively prevent lightning damage to equipment and improve the safety factor of the power generation system, and a knife switch on the grid-connected side to facilitate effective operation and maintenance of the equipment.

Key Features:

  • Smart Controls: Microcomputer time controller reduces nighttime no-load losses.

  • Safety Protections:

  • Temperature monitor with auto-shutdown at critical thresholds.

  • Over/under-voltage self-reset protector prevents islanding.

  • Surge arrester for lightning protection.

  • Grid-side knife switch for maintenance.

  • Flexible Configurations: Available in single/multi-unit combinations (1:2, 1:3, etc.) for scalable PV systems.

Technical data:

Operating Conditions

  • Ambient Temperature: -15 to +50°C

  • Relative Humidity: 20 to 90% RH

  • Atmospheric Pressure: 860 to 1060 hPa

  • Storage/Transport Temperature: -20 to +55°C

  • Rated Capacity: 5-300KVA

  • Input Voltage: 800V

  • Input Current: As per actual capacity

  • Output Voltage: 400V

  • Output Current: As per actual capacity

  • Connection: Dyn11 (△/Y), Yny0 (Y/Y)

  • Efficiency: ≥96%

  • Frequency: 50Hz/60Hz

  • Insulation Impedance: ≤500MΩ at 25mA

  • Inductive Withstand Voltage: 125Hz/800V/60s

  • Insulation Class: Class H (155°C temperature resistance)

  • Noise Level: ≤30dB

  • Temperature Rise: ≤115K allowable

  • Impedance Voltage Drop: ≤4%

  • Cooling Structure: Forced air cooling with temperature controller (fan starts automatically at set temperature per customer requirements)

  • Protection Class: IP54

  • Anti-Interference Method: Copper foil isolation, shielded grounding

  • Waveform Distortion: No additional distortion

  • Electrical Strength: 3000V AC power frequency sine voltage for 1min without breakdown/flashover

  • Insulation Resistance (input/output to ground): Test voltage ≥1000VDC, insulation resistance >50MΩ

  • Overload Capacity: 2x rated current for 1min

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Neutral line current is actually greater than live line current? Why?
Neutral line current is actually greater than live line current? Why?
In a three-phase four-wire power distribution system, it is a consensus among industry insiders that the neutral line current should be very small when the three-phase loads are balanced. However, more and more phenomena are subverting this concept.For example, the advertising light boxes around a building use fluorescent lighting with electronic ballasts. The loads on the three-phase lines are balanced, with each phase current being approximately 90A, but the neutral line current reaches 160A.I
RW Energy
08/01/2025
Difference Between EMF and Voltage
Difference Between EMF and Voltage
One of the key differences between electromotive force (EMF) and voltage is that EMF refers to the energy supplied to charges, while voltage represents the energy required to move a unit charge from one point to another. Other distinctions between the two are detailed in the comparison chart below.Comparison ChartDefinition of VoltageVoltage is defined as the energy required to move a unit charge from one point to another. It is measured in volts (V) and denoted by the symbolV. Voltage is induce
Dyson
08/01/2025
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Currently, the market price of copper remains high, fluctuating in the range of 70,000 to 80,000 yuan per ton. In contrast, the price of aluminum stays low, lingering in the range of 18,000 to 20,000 yuan per ton. For power transformers, replacing copper windings with aluminum windings in design will undoubtedly significantly reduce the material cost of products, bringing substantial cost savings to end customers.For a long time, it has been widely believed in the industry that aluminum windings
Ron
08/01/2025
What should be done if the neutral line current is too large?
What should be done if the neutral line current is too large?
As we all know, if an electrical line exceeds its rated load, it will overheat severely, and may even cause a fire. For safety reasons, overcurrent protection devices are therefore installed on lines. Whenever the current in the line exceeds the rated value, the overcurrent protection device will automatically cut off the line to prevent fire. The "excessive neutral line current" mentioned here refers to the phenomenon where the neutral line current is excessively high (more than 1.5 times the p
RW Energy
08/01/2025
What does the lifting inspection of a transformer core include?
What does the lifting inspection of a transformer core include?
1.Environmental Requirements for Transformer Core-Lifting Inspection1.1 General Environmental ConditionsCore - lifting operations are preferably carried out indoors. For large transformers that have to be operated outdoors due to specific conditions, sufficient measures must be taken to prevent moisture and dust contamination.Core - lifting should not be conducted during rainy or snowy weather or when the relative humidity exceeds 75%.The ambient air temperature during core - lifting should not
Rockwell
08/01/2025
Transformer operation and maintenance
Transformer operation and maintenance
Transformer Operating TemperatureDuring operation, transformers generate copper losses and iron losses, both of which are converted into heat, causing the transformer’s temperature to rise. Most transformers in China use Class A insulation. Due to heat transfer characteristics, significant temperature differences exist between different components during operation: winding temperature is the highest, followed by the core, and then the temperature of the insulating oil (with upper-layer oil being
Encyclopedia
07/31/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!