• Photovoltaic inverter grid-connected transformers
Photovoltaic inverter grid-connected transformers
discuss personally
Model
SGG/SD-60kVA
SGG/SD-80kVA
SGG/SD-100kVA
SGG/SD-25kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic inverter grid-connected transformers
Rated frequency 50/60Hz
Rated capacity 60KVA
Series SGG
Product Detail

Product Overview

An isolated transformer is a double-winding transformer that not only achieves voltage transformation in the power grid but also provides electrical safety isolation between input and output windings. This feature effectively prevents electric shock hazards when the human body comes into simultaneous contact with live components (or metal parts that may become charged due to insulation damage) and the ground. Additionally, it can isolate the third harmonics in the power grid, reduce heat generation during equipment operation, and extend the service life of insulating materials. It also functions to suppress and eliminate interferences such as noise, clutter, high voltage, and surges in the power grid, providing a pure power environment for equipment.

The dry-type photovoltaic transformers produced by our company are special transformers designed for photovoltaic grid-connected inverters. Adopting a foil winding process, the transformer core features a full-joint structure, and the core laminations are made of low-loss oriented silicon steel sheets, offering significant advantages of low loss, high efficiency, and low temperature rise. This series of transformers is suitable for circuits with an AC frequency of 50Hz/60Hz and a rated voltage below 690V, and can be custom-designed and manufactured according to specific user requirements.

Product features

  • Energy-saving and low-noise:High-quality cold-rolled silicon steel sheets are used for stacking; The special dipping process is used to effectively reduce the vibration and noise during operation; As well as the introduction of new processes and technologies such as the design of high-temperature resistant insulation materials, the transformer is more energy-saving and quieter. The coil has a ventilation groove to allow for smooth air flow, effectively reducing the coil temperature.

  • High reliability:The structure is reasonable, the efficiency is high, the waveform is not distorted, it is convenient and reliable to use, it can run for a long time, and the performance indicators fully meet the standard requirements of GB/6450 dry-type power transformer. It can isolate the power supply of the main power grid, anti-shock, anti-interference, and anti-lightning.

  • Eco-friendly features:It has heat resistance, moisture resistance, stability, chemical compatibility, low temperature resistance, radiation resistance and non-toxicity.

  • Versatility:From a single transformer to a multi-functional combined transformer with air cooling, protective housing, transformer and so on.

Model specifications:

Note:The dimensions and technical indicators of the above products can be customized according to customer requirements.

Application scenarios:

SGG/SD series photovoltaic inverter grid-connected transformer is a supporting product of solar photovoltaic, its rated input voltage is AC three-phase 270V, rated output voltage is AC three-phase 400V, rated working frequency is 50/60HZ, it will be the direct current in the solar energy through the photovoltaic inverter inverter out of the three-phase AC 270V voltage isolation and step-up into three-phase AC 400V voltage, in order to be integrated into the grid or directly supply the single-phase 220V and three-phase 380V AC power supply required by users.

 

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!