• 250kVA-2500 kVA Compact substation(Prefabricated Substation)
  • 250kVA-2500 kVA Compact substation(Prefabricated Substation)
250kVA-2500 kVA Compact substation(Prefabricated Substation)
discuss personally
Model
YBM-800
YBM-630
YBM-250
YBM-1250
Basic info
Brand Vziman
Model NO. 1250 kVA Compact substation
Rated voltage 35kV
Capacity 800kVA
Series Compact Substation
Product Detail

Product overview:

  • 250- 2500kVA Compact substation can replace the traditional indoor substation, can meet the user's electric energy measurement, reactive power compensation, high and low voltage.

  • schemes and other configuration requirements, representing the development direction of small and medium-sized substations.

  •  Rated AC frequency 50Hz/60HZ, maximum operating voltage to 35KV, maximum operating current to 5000A.

  • This product is suitable for industrial and mining enterprises, wharfs, public places, high-rise buildings and residential areas.

  • Products are mainly exported to Asia, Africa and other regions, providing OEM/ODM services.

  • Standard: IEC60067 GB 17467-2010, etc.

Product advantages:
Leading technology:

  • Fully enclosed and insulated structure, safe and reliable operation.

  • Easy to operate, maintenance-free, low equipment cost.

The shell:

  • The casing has the characteristics of firm, heat insulation and ventilation, stable performance (anti-corrosion, dustproof, waterproof) and beautiful appearance.

  • Various choice of shell materials, such as steel plate, composite plate, stainless steel plate, cement plate and other protection grade (IP67) .

Functional units:

  • Divided into high voltage room, low voltage room, transformer room three independent areas.

  • XGN15, HXGN17 or SF6 switchgear is selected for high pressure chamber.

  • The low-voltage side adopts panel or cabinet mounted structure to form the power supply scheme required by users, which can meet the power distribution, lighting distribution,

    reactive power compensation, energy metering and other functions. The main switch generally uses universal circuit breaker, but also can choose intelligent circuit breaker, flexible installation, easy operation.

  • The transformer can be fully sealed oil-immersed transformer or dry transformer.

Busbar system:

  • Three-phase four-wire system or three-phase five-wire system.

  •  High quality three phase tinned bus copper bar, high mechanical strength, good heat dissipation..

Product parameters:

Conditions of use:

  •  The ambient air temperature shall not exceed a maximum of 45 ° C and a minimum of -45 ° C.

  •  The altitude is not more than 1000m, and can reach 4000m if special custom transformers and low-voltage components are used.

  •  The vertical inclination is not more than 5°, and there is no violent vibration and no impact.

  •  Air humidity not greater than 90% (+25℃).

  •  No conductive dust, no explosion hazard, no corrosive metal and electrical components in the gas place.

  • Outdoor wind speed should not exceed 35m/s.

  •  The above normal operating environment conditions, customers can be customized with WONE you Electric to solve.

Ordering instructions:

The customer shall provide the following information:

  • Main loop scheme diagram and secondary loop system diagram.

  • Electrical schematic diagram of auxiliary circuit and wiring terminal layout.

  • Equipment layout drawing, combination drawing, floor plan drawing.

  • Model, specification and quantity of main electrical components of the equipment.

  • Incoming and outgoing line method and cable specifications.

  • Equipment shell material and color.

  • Other special requirements can be negotiated with the manufacturer.

  • Welcome customers to visit the factory, provide OEM/ODM protection level.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!