• UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer
UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer
discuss personally
Model
ZGS-500-33
ZGS-100-33
Basic info
Brand Vziman
Model NO. UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer
Rated frequency 50/60Hz
Rated capacity 500kVA
Primary voltage 33kV
Series ZGS
Product Detail

Description:

This is a single-phase oil-immersed pad-mounted transformer certified by UL, specially designed for outdoor installation. It complies with UL 1561 (Dry-Type Transformer) or UL 1562 (Oil-Immersed Transformer) standards, suitable for capacity ranges of 15-500kVA, with voltage classes covering 7.2kV-34.5kV (high-voltage side) and 120-600V (low-voltage side). Its features include:

 

  • Structural Form: Adopts Pad-Mounted (box-type floor-mounted) design with a fully sealed structure, reaching IP65/66 protection rating, and can be directly placed on concrete foundations.
  • Insulation Medium: Uses mineral oil or high-flash-point silicone oil as insulation and cooling media, with fire and explosion protection performance (complying with UL 1203 explosion-proof standards).
  • Voltage Adaptation: The high-voltage side supports multiple voltage classes such as 7.2kV, 12.47kV, 13.8kV, 25kV, 34.5kV, etc., while the low-voltage side outputs 120V/240V (single-phase three-wire) or 208V/480V/600V (three-phase four-wire).

Core Functions:

  • Voltage Conversion: Steps down medium voltage (e.g., 7.2kV) to low voltage (e.g., 240V) to meet the power demand of residential, commercial, or small industrial loads.
  • Safety Isolation: Isolates the high and low voltage sides through an oil-immersed insulation design to improve safety.
  • Overload Protection: Equipped with a temperature controller and pressure relief valve, which automatically cuts off power when the oil temperature exceeds the set value (e.g., 80°C) or internal pressure is abnormal.
  • Environmental Adaptation: Withstands harsh environments such as high temperature, humidity, and dust, suitable for long-term outdoor operation.

Typical Application Scenarios:

  • Residential Power Distribution: Provides single-phase 240V power for individual villas and residential areas, supporting high-power devices such as air conditioners and water heaters.
  • Commercial Facilities: Supplies 120V/240V power for convenience stores, small shopping malls, gas stations, etc., meeting the needs of lighting and cash register systems.
  • Small Industrial Loads: Provides power for farms and small processing plants, such as driving water pumps and small motors.
  • Renewable Energy Access: Serves as a step-up or step-down device in photovoltaic and wind power projects, adapting to distributed power generation scenarios.

Parameter:

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!