• UL Listed Three Phase Pad Mounted Power Transformer
UL Listed Three Phase Pad Mounted Power Transformer
discuss personally
Model
ZGS-2500-33
ZGS-2500-11
ZGS-1000-33
ZGS-1000-11
ZGS-200-33
ZGS-200-11
Basic info
Brand Vziman
Model NO. UL Listed Three Phase Pad Mounted Power Transformer
Rated frequency 50/60Hz
Rated capacity 2500kVA
Primary voltage 33kV
Series ZGS
Product Detail

Description:

The UL-listed three-phase pad-mounted power transformer is an outdoor power distribution device compliant with the safety standards of Underwriters Laboratories (UL). It adopts a fully sealed pad-mounted structure, specially designed for medium and low-voltage power distribution systems. Its core characteristics are as follows:

Structural Standards:

  • Complies with UL 1562 (oil-immersed transformers) or UL 1836 (dry-type transformers) certifications, with a protection rating typically reaching IP65/66. It can be directly installed on concrete foundations and adapts to harsh outdoor environments (such as rain, dust, and high temperatures).

Electrical Parameters:

  • Capacity Range: Usually 50kVA to 5000kVA, meeting the load requirements of different scales.
  • Voltage Classes: The high-voltage side commonly includes 7.2kV, 12.47kV, 13.8kV, 34.5kV, etc.; the low-voltage side outputs three-phase four-wire voltages such as 208V/120V, 480V/277V, 600V (compatible with North American standards).

Insulation and Cooling:

  • Oil-Immersed Type: Uses mineral oil or environmentally friendly high-flash-point oil (such as silicone oil) as the insulation medium, combining cooling and fireproof performance (complying with UL 1203 explosion-proof standards).
  • Dry-Type (Optional): High-voltage windings are cast with epoxy resin, requiring no maintenance, suitable for scenarios with higher fireproof requirements.

Core Functions:

Power Conversion and Distribution:

  • Steps down medium-voltage power grids (e.g., 13.8kV) to low voltage (e.g., 480V), providing stable power for three-phase loads (such as motors and large equipment), while supporting multi-loop 分户配电 (household distribution).

Safety and Reliability Assurance:

  • The fully sealed structure isolates external pollution, preventing moisture and dust from affecting insulation performance.
  • Equipped with a temperature controller, pressure relief valve, and gas relay (for oil-immersed types), it automatically protects against short circuits or fire risks when oil temperature is too high (e.g., exceeding 95°C) or internal faults occur.
  • UL certification ensures products comply with North American safety codes (such as short-circuit withstand capacity and insulation voltage standards).

Grid Compatibility:

  • Supports harmonic suppression design (optional filter windings), reducing interference from non-linear loads (such as frequency converters and data center equipment) to the power grid and improving power quality.

Typical Application Scenarios:

Commercial and Industrial Sectors:

  • Data Centers/Bitcoin Mining Farms: Supplies three-phase 480V power for server clusters and mining machines, supporting high-load continuous operation. Redundant windings are often configured to ensure 99.99% power availability.
  • Manufacturing: Drives three-phase motors (such as fans, water pumps, machine tools), suitable for factory production lines, food processing plants, etc.
  • Commercial Parks: Provides three-phase power (such as elevators, air conditioning systems) and lighting distribution for shopping malls, office buildings, hospitals, etc.

Municipal and Infrastructure:

  • Residential Power Distribution: Serves as a community substation, stepping down the municipal medium-voltage grid for distribution to each unit (e.g., three-phase 208V access, converted to single-phase 120V for households).
  • Transportation Hubs: Powers escalators, lighting systems, and monitoring equipment in subway stations and airports.

New Energy and Special Scenarios:

  • Distributed Generation: Acts as a grid-connected transformer in photovoltaic and wind power projects (e.g., 34.5kV step-up side) or regulates voltage in microgrids to match loads.
  • Harsh Environments: Corrosion-resistant coatings (such as zinc-nickel alloy casings) are used in coastal areas, and seismic designs (complying with UL vibration test standards) are configured in mining areas to adapt to salt spray, dust, and other environments.

Parameter:

 

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the