• 250kVA-2500 kVA Compact substation(Prefabricated Substation)
  • 250kVA-2500 kVA Compact substation(Prefabricated Substation)
250kVA-2500 kVA Compact substation(Prefabricated Substation)
discuss personally
Model
YBM-800
YBM-630
YBM-250
YBM-1250
Basic info
Brand Vziman
Model NO. 1250 kVA Compact substation
Rated voltage 35kV
Capacity 250kVA
Series Compact Substation
Product Detail

Product overview:

  • 250- 2500kVA Compact substation can replace the traditional indoor substation, can meet the user's electric energy measurement, reactive power compensation, high and low voltage.

  • schemes and other configuration requirements, representing the development direction of small and medium-sized substations.

  •  Rated AC frequency 50Hz/60HZ, maximum operating voltage to 35KV, maximum operating current to 5000A.

  • This product is suitable for industrial and mining enterprises, wharfs, public places, high-rise buildings and residential areas.

  • Products are mainly exported to Asia, Africa and other regions, providing OEM/ODM services.

  • Standard: IEC60067 GB 17467-2010, etc.

Product advantages:
Leading technology:

  • Fully enclosed and insulated structure, safe and reliable operation.

  • Easy to operate, maintenance-free, low equipment cost.

The shell:

  • The casing has the characteristics of firm, heat insulation and ventilation, stable performance (anti-corrosion, dustproof, waterproof) and beautiful appearance.

  • Various choice of shell materials, such as steel plate, composite plate, stainless steel plate, cement plate and other protection grade (IP67) .

Functional units:

  • Divided into high voltage room, low voltage room, transformer room three independent areas.

  • XGN15, HXGN17 or SF6 switchgear is selected for high pressure chamber.

  • The low-voltage side adopts panel or cabinet mounted structure to form the power supply scheme required by users, which can meet the power distribution, lighting distribution,

    reactive power compensation, energy metering and other functions. The main switch generally uses universal circuit breaker, but also can choose intelligent circuit breaker, flexible installation, easy operation.

  • The transformer can be fully sealed oil-immersed transformer or dry transformer.

Busbar system:

  • Three-phase four-wire system or three-phase five-wire system.

  •  High quality three phase tinned bus copper bar, high mechanical strength, good heat dissipation..

Product parameters:

Conditions of use:

  •  The ambient air temperature shall not exceed a maximum of 45 ° C and a minimum of -45 ° C.

  •  The altitude is not more than 1000m, and can reach 4000m if special custom transformers and low-voltage components are used.

  •  The vertical inclination is not more than 5°, and there is no violent vibration and no impact.

  •  Air humidity not greater than 90% (+25℃).

  •  No conductive dust, no explosion hazard, no corrosive metal and electrical components in the gas place.

  • Outdoor wind speed should not exceed 35m/s.

  •  The above normal operating environment conditions, customers can be customized with WONE you Electric to solve.

Ordering instructions:

The customer shall provide the following information:

  • Main loop scheme diagram and secondary loop system diagram.

  • Electrical schematic diagram of auxiliary circuit and wiring terminal layout.

  • Equipment layout drawing, combination drawing, floor plan drawing.

  • Model, specification and quantity of main electrical components of the equipment.

  • Incoming and outgoing line method and cable specifications.

  • Equipment shell material and color.

  • Other special requirements can be negotiated with the manufacturer.

  • Welcome customers to visit the factory, provide OEM/ODM protection level.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!