• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


2500kVA 11kV Oil-immersed distribution transformer three-phase

  • 2500kVA 11kV Oil-immersed distribution transformer three-phase

Key attributes

Brand Vziman
Model NO. 2500KVA 11KV Oil-immersed distribution transformer three-phase
Rated voltage 11kV
Rated capacity 2500kVA
Series S

Product descriptions from the supplier

Description

Description:

Oil immersed transformer ,use our company special calculation and validation procedures to make sure theperformance of products. superior process equipment ,elaborate materialselecting and efficient manufacturing make the transformer have smallvolume,light weight,low loss,low partial discharge,low noise characteristics.

The product is stable,reliable,economic, environmental protection. lt can beapplied to many places such as power plants,transformer substation ,largeindustrial mining and petrochemical enterprise and so on.

Features:

  • Ultralow no-load loss

  • Energy saving and great power consuming efficiency

  • Copper coil winding, strong short circuit resistance ability

  • Dyn11 coil connection decrease the influences of harmonic wave

  • Fully sealed structure for maintenance free

  • Slow insulation aging & longer serving life

Parameters:

Oil-immersed distribution transformer three-phase

Model NO.

S-2500-11

Product classification

Distribution transformer

Rated capacity

2500kVA

Primary voltage

11kV

Secondary voltage

0.4kV

Number of phase

3

Number of winding

2

Rated frequency

50Hz

Tap changer

OCTC

Tap range

±2×2.5%

Vector group

Yd11400v delta 11kv star 

Cooling system

ONAN

No-load loss

3800+10%

Load loss

19000+10%

Standard

IEC60076

Impedance

4.75±10%

Basic insulation level

75/28kv

Winding material ( H.V & L.V)

Copper

The way the bushing appears

Porcelain

Power frequency withstand voltage

——

Lightning impulse

——

The temperature rise—Winding

——

The temperature rise --Top oil

——

Tank color

——

Creepage distance

——

Environmental requirement

——

Transformer structure

Sealed

External dimensions:

企业微信截图_17240297972200.png

Size

2425mm×1520mm×2170mm

Weight

3080KG


Environmental requirement:

Max. ambient temperature


Altitude



What are the structural characteristics of oil-immersed distribution transformers?

Definitions and Characteristics:

  • Oil-Immersed: It means that the iron core and windings of the transformer are immersed in insulating oil, and the oil plays a dual role of cooling and insulation.

  • Distribution Transformer: It is used to convert high-voltage electrical energy into low-voltage electrical energy for users' use.
    Three-Phase: Usually, it means that the transformer has three independent windings and is applicable to three-phase alternating current systems.

Structural Characteristics:

  • Iron Core: It is usually made by laminating high-quality silicon steel sheets, featuring low loss and low noise.

  • Windings: The primary winding and the secondary winding are usually wound with copper wires, possessing excellent electrical conductivity and mechanical strength.

  • Insulating Oil: The inside of the transformer is filled with insulating oil. The oil not only plays a cooling role but also provides good insulation performance.

  • Oil Tank: The iron core and windings of the transformer are installed in the oil tank. The oil tank is usually made of steel plates and has good sealing performance.

  • Cooling System: Depending on the power level, oil-immersed transformers can adopt natural cooling, air cooling or forced oil circulation cooling methods.

  • Bushing: The high-voltage and low-voltage leads are led out through the bushing. The bushing has good insulation performance to ensure safe operation.


Documentation Resource Library
Restricted
Vziman IEC/ ANSI Oil-immersed Power transformer selection catalog
Catalogue
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff: 300
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How Often Should Transformers Be Overhauled?
    1. Transformer Major Overhaul Cycle The main transformer shall undergo a core-lifting inspection before being put into service, and thereafter a core-lifting overhaul shall be performed every 5 to 10 years. Core-lifting overhaul shall also be carried out if a fault occurs during operation or if issues are identified during preventive tests. Distribution transformers operating continuously under normal load conditions may be overhauled once every 10 years. For on-load tap-changing transformers, t
    12/09/2025
  • Adjustment and Precautions for H61 Oil Power 26kV Electric Transformer Tap Changers
    Preparatory Work Before Adjusting the Tap Changer of H61 Oil Power 26kV Electric Transformer Apply for and issue a work permit; carefully fill out the operation ticket; conduct a simulation board operation test to ensure the operation is error-free; confirm the personnel who will carry out and supervise the operation; if load reduction is required, notify affected users in advance. Before construction, power must be disconnected to take the transformer out of service, and voltage testing must be
    12/08/2025
  • H59/H61 Transformer Failure Analysis and Protection Measures
    1.Causes of Damage to Agricultural H59/H61 Oil-Immersed Distribution Transformers1.1 Insulation DamageRural power supply commonly uses a 380/220V mixed system. Due to the high proportion of single-phase loads, H59/H61 oil-immersed distribution transformers often operate under significant three-phase load imbalance. In many cases, the degree of three-phase load imbalance far exceeds the limits permitted by operational regulations, causing premature aging, deterioration, and eventual failure of th
    12/08/2025
  • What Is an H61 Distribution Transformer? Uses & Setup
    H61 distribution transformers refer to transformers used in power distribution systems. In a distribution system, high-voltage electricity must be converted into low-voltage electricity via transformers to supply electrical equipment in residential, commercial, and industrial facilities. The H61 distribution transformer is a type of infrastructure equipment primarily used in the following scenarios: Supplying power from high-voltage grids to low-voltage grids: During power delivery, high-voltage
    12/08/2025
  • How to Diagnose Faults in H59 Distribution Transformers by Listening to Their Sounds
    In recent years, the accident rate of H59 distribution transformers has shown an upward trend. This article analyzes the causes of failures in H59 distribution transformers and proposes a series of preventive measures to ensure their normal operation and provide effective assurance for power supply.H59 distribution transformers play a vital role in power systems. With the continuous expansion of power system scale and the increasing single-unit capacity of transformers, any transformer failure n
    12/08/2025
  • What lightning protection measures are used for H61 distribution transformers?
    What lightning protection measures are used for H61 distribution transformers?A surge arrester should be installed on the high-voltage side of the H61 distribution transformer. According to SDJ7–79 "Technical Code for Design of Overvoltage Protection of Electric Power Equipment," the high-voltage side of an H61 distribution transformer should generally be protected by a surge arrester. The grounding conductor of the arrester, the neutral point on the low-voltage side of the transformer, and the
    12/08/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.