• 12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style)
12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style)
discuss personally
Model
YB-40.5
YB-36
YB-24
YB-12
Basic info
Brand ROCKWILL
Model NO. 12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style)
Rated voltage 36kV
Rated normal current 630A
Rated frequency 50/60Hz
Rated capacity 50 - 2500kVA
Series YB
Product Detail

Description :

YB series products is a kind of set of  equipment which assembles the MV switch  apparatus, transformer, LV distribution  equipment together according to fixed  connection scheme. This series substation is  suitable for neighborhood unit, hotel, large-scale  work site and high building that the voltage is  12kV /24kV/36kV/40.5kV, the frequency is  50Hz and the capacity is under 2500kvA.

Main Designation Characteristics :

  • The crust of the substation is designed according to the foreign advanced technology and  physical reality. We provide many kinds of crust material such as aluminum alloy steel  composite stainless steel board and non metal material(glass fiber).

  • The HV side use charge switch or vacuum circuit breaker. The transformer could be oil  type hermetically-sealed type and dry type.

  • The proof of the box is double layers structure and between the layers is filled with foam.  There are independent boards in HV and LV room, and in the transformer room will install  auto thermal controller heater and cooling equipment.

Note: we offer special customized products according to client’s requirement.

Service environment:

  • Air temperature: Maximum temperature: +40℃; Minimum temperature:-25℃;

  • Humidity: Monthly average humidity 95%; Daily average humidity 90%;

  • Altitude above sea level: Maximum installation altitude: 2500m;

  • Ambient air not apparently polluted by corrosive and flammable gas, vapor etc;

  • No frequent violent shake.

Main technical specifications:

12/24/36kV

12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style).png

40.5kV

12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style).png

Main Primacy Wiring Circuit Schemas for Substation(40.5kV):

Wiring type A-40.5kV:

12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style).png

Wiring type B-40.5kV:

12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style).png

Note: we offer special customized products according to client’s requirement.

Wiring type C -40.5kV:

12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style).png

Wiring type D -40.5kV:

12kV 24kV 36kV 40.5kV Prefabricated Substation(US-style, EU-style).png

Note: we offer special customized products according to client's requirement.

What is a prefabricated substation?

A:A prefabricated substation is an electrical substation with pre - assembled components in factory, featuring modular design, easy combination via standardized interfaces, and wide - ranging scenario adaptability.

What is a package substation?

A: A package substation is a prefabricated, all - in - one unit integrating high - voltage equipment, transformers and low - voltage devices, used to transform and distribute electricity efficiently.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Documents
Restricted.
Prefabricated Substation(US-style, EU-style) 12kV... 24kV... 36kV... 40.5kV...
Manual English
Consulting
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!