126kV 145kV high voltage SF6 circuit breaker

  • 126kV 145kV high voltage SF6 circuit breaker

Key attributes

Brand ROCKWILL
Model NO. 126kV 145kV high voltage SF6 circuit breaker
Rated voltage 126kV
Rated normal current 3150A
Rated frequency 50/60Hz
Rated short circuit breaking current 40kA
Series LW36-126(145)

Product descriptions from the supplier

Description

Product introduction:

LW36-126(145) (W) circuit breaker is suitable for single-phase operation, three-phase electrical linkage and three-phase mechanical linkage, Grid frequency 50 / 60Hz, neutral grounded system and neutral ungrounded system, C2 level of back-to-hack capacitor bank and C2 level of no-load line-Charing breaking capacity and no-load cable-charging breaking capacity.  products have reached the leading domestic and international advanced level in advanced technology and quality reliability.

By adopting SF6 gas as the arc extinguisher and insulation medium, using advanced self-energy power arc extinguishing technology and being equipped with new type spring actuating mechanism, this product has features such as long electrical end-durance, less operating power, low noise, and high reliability. it has a simple structure, small size, long maintenance-free cycle. In the current trend of oil-free and high-capacity electricity equipment’s.

Main characteristic:

  • Reliable breaking performance: This circuit breaker can consecutively break 40kA short circuit current for 22 times without overhaul; Neutral grounded system and neutral ungrounded system, first-pole-to-clear factor 1.3/1.5; C2 level of no-load line-charging breaking capacity and no-load cable-charging breaking capacity, C2 level of the back-to-back capacitor bank breaking capacity, no restrike.

  • Reliable mechanical operating performance: The mechanical life of the circuit breaker under continuous operation can reach up to 10000 times M2 class.

  •  Reliable seismic performance: Comply with lEEE693-2018 1.0g high seismic level and ETG Chile seismic standard requirements.

  • Reliable current-carrying function: After 3780A temperature-rise test, the temperature-rise values at all points still have much margin.22.

  •  Reliable insulation ability: creepage distance of external insulation>31mm/kV; strong pollution resistance; suitable for safe running in hard environments with an altitude of no more than 3000m.

  • Reliable sealing performance. it is guaranteed that the SF6 gas has an annual gas leakage rate of far less than 0.5%.

  • Strict dehumidification process for component parts of the product the SF6 water content is far lower than similar products.

  • Simple structure, long overhaul cycle, convenient on-site installation and debug, safe and reliable running experience of more than 25000 sets, applied worldwide.

  • Optional phase closing device.

  • Self-energy arc extinguishing principle is adopted for the circuit breaker, The operating power is low.The valve plate of the arc extinguishing compartment is made of new-type lightweight Zinc-base alloy. Compared with the traditional materials adopted for similar products, this material has more stable and reliable gas feature and breaking performance;

  • The spout is made of import PTFE mixed with other micro-components. lt has stable breaking performance and strong ablation resistance.

  • The unique locking-up measure is used for the insulating pulling rod of the breaker to ensure more reliable running of the breaker.

  • Spring actuating mechanism with small operating power, light weight, and low noise is adopted for zero leakage and high reliability, High-strength cast aluminum machine fame is adopted for high strength, zero welding stress, and pleasing exterior appearance. The important component pats in the mechanism are forged with quality alloy steel for high strength and abrasion resistance, which can ensure low fault rate under frequent operation of the breaker.

  • The product has a novel and lively exterior appearance and compact structure, The installation foundation frame is made of thick steel board being overall bended. Hot zinc impregnation is adopted for the surface, The exposed fastening pieces are high-strength hot-galvanized bolts, The interval driving connecting rods are made of high-strength aluminum sectional material or stainless stool sectional malarial, The case of the mechanism is made of stainless steel ,The product has excellent ant-corrosion performance.

Main technical parameters:

1732518156932.png

Instructions on placing orders  : 

  • Model and format of the circuit breaker.

  • Rated electrical parameters (voltage, current, breaking current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Rated control circuit electrical parameters (Rated voltage of energy-store moter and Rated voltage of opening, closing coil).

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered).

  • The wire connecting direction of the primary upper terminal.

What are the performance characteristics of the canister circuit breaker?

High Insulation Performance:

  • High Insulation Performance: Whether using sulfur hexafluoride (SF6) gas or insulating oil as the insulating medium, tank-type circuit breakers possess a high level of insulation. They can withstand system operating voltages and various overvoltages, ensuring the safety of both equipment and personnel.

Strong Arc-Quenching Capability:

  • Strong Arc-Quenching Capability: The special design of the arc quenching chamber and the arc-quenching medium enable tank-type circuit breakers to rapidly extinguish arcs when interrupting short-circuit currents. This reduces the burn damage to the contacts, extends the electrical life and interrupting performance of the circuit breaker, and lowers the downtime and maintenance costs associated with faults.

Good Environmental Adaptability:

  • Good Environmental Adaptability: The enclosed tank structure provides excellent resistance to contamination, moisture, and windblown sand. This allows the circuit breaker to operate stably in various geographical environments and climatic conditions, making it suitable for outdoor substations, industrial and mining enterprises, and other locations.


Documentation Resource Library
Restricted
Live Tank Breakers Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the differences between this product and similar products from ABB/Siemens?
A:

The LW10B \ lLW36 \ LW58 series products in the sample booklet are porcelain column SF ₆ circuit breakers based on the ABB'LTB series improvement, with voltage coverage of 72.5kV-800kV, using Auto Buffer ™ Self powered arc extinguishing technology or vacuum arc extinguishing technology, integrated spring/motor driven operating mechanism, supports various customized services, covering 40.5-1100kV full voltage levels, with outstanding modular design and strong customization ability, suitable for projects that require flexible adaptation to different power grid architectures. Made in China, with fast global service response speed, high logistics efficiency, and high reliability at a reasonable price.

Q: What are the core differences between live tank circuit breakers and tank circuit breakers?
A:
  1. The core differences between porcelain column circuit breakers and tank circuit breakers—two main structural types of high-voltage circuit breakers—lie in six key aspects.
  2. Structurally, porcelain column types are supported by porcelain insulation pillars, with open-layout components like arc extinguishing chambers and operating mechanisms. Tank types use metal-sealed tanks to encapsulate and highly integrate all core parts.
  3. For insulation, the former relies on porcelain pillars, air, or composite insulating materials; the latter combines SF₆ gas (or other insulating gases) with metal tanks.
  4. Arc extinguishing chambers are mounted on the top or pillars of porcelain columns for the former, while built inside metal tanks for the latter.
  5. In application, porcelain column types suit outdoor high-voltage distribution with a dispersed layout; tank types adapt flexibly to indoor/outdoor scenarios, especially space-constrained environments.
  6. Maintenance-wise, the former’s exposed components enable targeted repairs; the latter’s sealed structure reduces overall maintenance frequency but requires full inspections for local faults.
  7. Technically, porcelain column types offer intuitive structure and strong anti-pollution flashover performance, while tank types boast excellent sealing, high SF₆ insulation strength, and superior resistance to external interference.
Q: What is a live tank circuit breaker? What voltage level is it suitable for they?
A:

live tank circuit breaker is a structural form of high-voltage circuit breaker, which is characterized by the use of ceramic insulation pillars to support key components such as arc extinguishing chamber and operating mechanism. The arc extinguishing chamber is usually arranged on the top or pillar of the ceramic pillar. It is mainly suitable for medium and high voltage power systems, with voltage levels covering the range of 72.5 kV to 1100 kV. live tank circuit breakers are common control and protection equipment in outdoor distribution devices such as 110 kV, 220 kV, 550 kV, and 800 kV substations.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application