Key attributes

Brand ROCKWILL
Model NO. 100kVA 135kVA 150kVA Three-phase dry-type power transformer
Rated frequency 50/60Hz
Rated capacity 150KVA
Series S(D)G

Product descriptions from the supplier

Description

Product Description

As a pioneer in China's power transformer industry, we have specialized in the R&D and manufacturing of power transformer equipment for decades, and established industry standards with core technologies.

Our 100kVA 135kVA 150kVA Three-Phase Dry-Type Power Transformer is engineered for superior performance, safety, and reliability in a wide range of commercial and industrial applications. Unlike liquid-filled units, this transformer utilizes advanced vacuum pressure impregnation (VPI) and encapsulation technology with high-class insulating materials, making it inherently flame-retardant, self-extinguishing, and free from oil leaks or environmental contaminants.

Designed for exceptional operational efficiency with low no-load and load losses, it significantly reduces energy consumption and total cost of ownership. Its robust construction ensures stable voltage transformation and distribution in demanding environments, from powering manufacturing equipment and HVAC systems to serving as a critical component in data centers and building infrastructure. With easy installation, minimal maintenance requirements, and a compact footprint, this 150kVA dry-type transformer represents a smart, safe, and eco-friendly power solution built for long-term dependability.

Product features

Special Transformer SG and DG Series include three-phase (single-phase) isolation transformers and three-phase (single-phase) autotransformers. They are primarily used in various high and low voltage complete electrical sets, import-export equipment, precision machine tools, UPS, electroplating, lighting, heating, communications, chemical industry equipment, and other applications for control power and power supply purposes. These transformers feature effective harmonic resistance, strong anti-interference capability, and high safety. Design and production strictly comply with IEC international standards and relevant GB national standards.

SG DG Dry-type Transformer Technical Parameters

The voltage classes of some of these Power Transformer include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV  69kV.72.5kV 88kV 110kV 115kV 123kV 125kV 126kV 132kV 138kV 145kV 150kV 154kV 161kV 170kV  220kV 225kV 230kV 245kV 275kV 330kV 345kV 363kV 380kV 400kV 500kV Power transformers of voltage ,and aboveand customization is available.

Product Name

Model Specification

Parameter Ratio (kV)

Connection Group

Overall Dimensions (Length * Width * Height, mm)

Foot Mounting Dimensions (mm)

Total Weight (kg)

Single-phase Small Dry-type Transformer

DG-1kVA

0.38/0.22

 

Dyn11/Yyn0

 

162 * 185 * 190

100 * 115

13

DG-1.5kVA

191 * 170 * 200

130 * 135

17

DG-2kVA

230 * 180 * 250

190 * 120

23

DG-2.5kVA

230 * 185 * 250

190 * 125

25

DG-3kVA

230 * 190 * 250

190 * 130

30

DG-4kVA

230 * 200 * 250

190 * 150

38

DG-5kVA

230 * 210 * 250

190 * 160

46

DG-6kVA

230 * 220 * 250

190 * 175

55

DG-8kVA

230 * 230 * 250

190 * 185

62

DG-10kVA

270 * 270 * 250

170 * 150

70

Three-phase Small Dry-type Transformer

SG-1kVA

0.315/0.38

0.315/0.4

0.38/0.38

0.38/0.22

0.38/0.22

0.62/0.4

0.69/0.4

280 * 140 * 280

200 * 90

19

SG-1.5kVA

280 * 155 * 280

200 * 105

24

SG-2kVA

280 * 160 * 280

200 * 110

26

SG-2.5kVA

280 * 170 * 280

200 * 120

29

SG-3kVA

310 * 170 * 300

200 * 125

38

SG-4kVA

310 * 175 * 300

200 * 130

42

SG-5kVA

360 * 170 * 350

200 * 125

50

SG-8kVA

410 * 175 * 400

200 * 125

72

SG-10kVA

410 * 180 * 400

200 * 135

78

SG-12kVA

410 * 195 * 400

200 * 145

92

SG-15kVA

410 * 195 * 400

200 * 145

92

SG-20kVA

480 * 225 * 450

200 * 165

130

SG-30kVA

520 * 350 * 550

280 * 300

210

SG-35kVA

540 * 350 * 610

300 * 300

230

SG-40kVA

580 * 350 * 610

300 * 300

270

SG-50kVA

580 * 350 * 610

300 * 300

310

SG-60kVA

710 * 450 * 720

400 * 400

360

SG-70kVA

710 * 450 * 720

400 * 400

390

SG-80kVA

850 * 500 * 720

450 * 450

400

SG-90kVA

850 * 500 * 780

450 * 450

420

SG-100kVA

850 * 500 * 780

450 * 450

430

SG-110kVA

850 * 500 * 780

450 * 450

450

SG-120kVA

850 * 500 * 820

450 * 450

480

SG-130kVA

850 * 500 * 780

450 * 450

500

SG-135kVA

870 * 600 * 820

500 * 550

520

SG-140kVA

870 * 600 * 820

500 * 550

540

SG-150kVA

870 * 600 * 820

500 * 550

550

Note: the above parameters are for reference only and can be customized according to customer requirements.

Conditions of use

  • The upper limit of ambient temperature is +40℃, and the lower limit is -5℃ (indoor).

  • The altitude does not exceed 1000m.

  • The daily average relative humidity ≤ 95%, and the monthly average relative humidity ≤90%.

  • For special sites, please state in advance, and our company will make corresponding design adjustments.

FAQ for
Q: What is the capacity range of power transformers up to 345kV, and what are the standardized capacity ratings?
A:
Transformer capacity is strongly related to voltage level, and the capacity range and standard values comply with international general specifications. Details are as follows:
  • Capacity range by voltage level: ① High Voltage (HV, 66kV - 220kV): 5MVA – 250MVA; ② Extra-High Voltage (EHV, 220kV - 400kV): 250MVA – 600MVA+. Higher capacities are usually achieved through forced cooling methods (e.g., ONAF, OFAF).
  • Standardized capacity ratings: Internationally accepted standard capacities include 30MVA, 45MVA, 60MVA, 90MVA, 100MVA, 120MVA, 150MVA, 200MVA, 250MVA, 315MVA, 400MVA, and 500MVA. These ratings are widely adopted in design and production.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • Analysis of Four Major Power Transformer Burnout Cases
    Case OneOn August 1, 2016, a 50kVA distribution transformer at a power supply station suddenly sprayed oil during operation, followed by burning and destruction of the high-voltage fuse. Insulation testing revealed zero megohms from the low-voltage side to ground. Core inspection determined that damage to the low-voltage winding insulation had caused a short circuit. Analysis identified several primary causes for this transformer failure:Overloading: Load management has historically been a weak
    12/23/2025
  • Commissioning Test Procedures for Oil-Immersed Power Transformers
    Transformer Commissioning Tests Procedures1. Non-Porcelain Bushing Tests1.1 Insulation ResistanceSuspend the bushing vertically using a crane or support frame. Measure the insulation resistance between the terminal and the tap/flange using a 2500V insulation resistance meter. The measured values should not deviate significantly from factory values under similar environmental conditions. For capacitor-type bushings rated 66kV and above with voltage sampling small bushings, measure the insulation
    12/23/2025
  • Purpose of Pre-Commissioning Impulse Testing for Power Transformers
    No-Load Full-Voltage Switching Impulse Testing for Newly Commissioned TransformersFor newly commissioned transformers, besides conducting necessary tests according to handover test standards and protection/secondary system tests, no-load full-voltage switching impulse tests are typically performed before official energization.Why Perform Impulse Testing?1. Check for Insulation Weaknesses or Defects in the Transformer and Its CircuitWhen disconnecting a no-load transformer, switching overvoltages
    12/23/2025
  • What are the classification types of power transformers and their applications in energy storage systems?
    Power transformers are core primary equipment in power systems that realize electrical energy transmission and voltage conversion. Through the principle of electromagnetic induction, they convert AC power of one voltage level to another or multiple voltage levels. In the transmission and distribution process, they play a critical role in "step-up transmission and step-down distribution," while in energy storage systems, they perform voltage step-up and step-down functions, ensuring efficient pow
    12/23/2025

Related Solutions

Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.