Quid est Regulator Stativus Voltage?

Edwiin
Campus: Commutator electricitatis
China

Typi Regulatorum Tensionis Statici

Regulator tensionis staticus praestat regulatores electromechanicos in respectu accurate controlis, responsionis, fidei et maintenance. Regulator tensionis staticus principaliter dividitur in duos typus. Hi sunt;

  • Regulator Tensionis Typus Servo

  • Regulator Amplificatoris Magnetici

Typi regulatorum tensionis statici describuntur infra in detaliis;

Regulator Tensionis Typus Servo

Characteristica principalis regulatoris tensionis typus servo est usus amplidyne. Amplidyne est genus amplificatoris electromechanici qui signum amplificat. Systema continet principalem excitatorem ductum ab arbore alternatoris et excitatorem auxiliarium cuius devolutio est regula per amplidyne.

Excitator auxiliaris et amplidyne sunt moti ab motore DC coniuncto ad ambas machinas. Excitator principalis habet circuitum magneticum saturatum et proinde habet tensionem output rudem. Armaturae principalis et auxiliaris excitorum sunt coniunctae in serie, et haec combinatio series excitat devolutionem alternatoris.

Operatio Regulatoris Tensionis Typus Servo

Transformator potentialis praebet signum proportionale signo output alternatoris. Terminales output alternatoris sunt coniuncti ad amplificatorem electronicum. Quando deviatio occurrerit in tensione output alternatoris, tunc amplificator electronicus mittit tensionem ad amplidyne. Output amplidyne alimentat tensionem ad devolutionem controlis amplidyne et sic mutat devolutionem excitatoris auxiliaris. Sic, excitator auxiliaris et principalis in serie ajustant currentem excitationis alternatoris.

Regulator Amplificatoris Magnetici

Elementum clavis amplificatorum magneticorum est spira nucleata ferrea quae habet winding additivam energizatam per currentem directum (DC). Hoc winding additivum servit scopo controlis relativiter altius potentiae currentis alternantis (AC) utendo minore potentia DC. Nucleus ferreus regulatoris instructus est duabus AC windings identicis, quae etiam nominantur windings oneris. Haec AC windings possunt coniungi vel in serie vel in parallelo, et in utroque casu, sunt coniunctae in serie cum onere.

Configuratio winding serie utitur quando requiritur responsum brevi tempore et alta tensio, dum configuratio winding parallela utilisatur pro applicationibus quae postulant responsum lente. Winding controlis alimentatur per currentem directum (DC). Quando non fluit currentis per winding oneris, AC winding praebet maximam impedanciam et inductanciam ad fontem AC. Proinde, currentis alternans ad onus restrictus est per altam reactantiam inductivam, ducens ad bassam tensionem oneris.

Quando applicatur tensio DC, fluxus magneticus DC transversus nucleum, eum impellit ad saturationem magneticam. Hoc processus reducit inductanciam et impedanciam windings AC. Ut crescat currentis DC per winding controlis, ita crescit etiam currentis alternans per winding field. Consequenter, modica rectificatio magnitudinis currentis oneris potest resultare in variatione significativa tensionis oneris.

Donum da et auctorem hortare

Suggestus

Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
02/05/2026
Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
01/30/2026
Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
01/29/2026
Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem