
Relais est instrumentum automaticum quod sensum habet conditionis abnormalis circuiti electrici et claudit suas contactus. Hi contactus deinde claudunt et complectuntur circuitum trip coil circuit breaker, ideo circuit breaker trippatur ad disjungendum partem vitiosam circuiti electrici ab reliqua parte sana circuiti.
Nunc disceptemus de quibusdam terminis praesidii relais.
Gradus Actuandi Signali:
Valorem quantitatis actuandae (voltage vel current) qui supra limen est, supra quem relais incipit operari.
Si valorem quantitatis actuandae augetur, effectus electromagneticus coil relais auctus est, et supra certum gradum quantitatis actuandae, mechanismus mobilis relais incipit moveri.
Gradus Restituendi:
Valorem current vel voltage infra quem relais aperit suas contactus et revertitur in positionem originalem.
Tempus Operantis Relais:
Iam post excedendum gradum actuandi quantitatis, mechanismus mobilis (exempli gratia discus rotans) relais incipit moveri et tandem claudit contactus relais in fine itineris sui. Tempus quod inter initium quando quantitas actuanda excedit valorem pickup et initium quando contactus relais clauduntur elapsus est.
Tempus Restituendi Relais:
Tempus quod inter initium quando quantitas actuanda minor fit quam valor restituendi et initium quando contactus relais revertuntur ad positionem normalem elapsus est.
Portata Relais:
Relais distantiae operatur quoties distantia visibilis relais minor est quam impedimentum praeconstitutum. Impedimentum actuandum in relais est functio distantiae in relais praesidii distantiae. Hoc impedimentum vel correspondentia distantia vocatur portata relais.
Relais praesidii systematis electrici possunt categorizari in varios typorum relais.
Typi relais praesidii principaliter basantur in eorum characteristica, logica, in parametris actuandis et mechanismo operationis.
Basati in mechanismo operationis, relais praesidii possunt categorizari ut relais electromagneticum, relais staticum et relais mechanicum. Relais nihil aliud est quam combinatio unius aut plurium contactuum apertorum aut clausorum. Hi omnes aut aliqui specifici contactus relais mutant suum statum quando parametri actuandi applicantur ad relais. Id est, contactus aperti fiunt clausi et contactus clausi fiunt aperti. In relais electromagneticum, haec clausura et apertura contactuum relais per actionem electromagneticam solenoidis efficitur.
In relais mechanicum, haec clausura et apertura contactuum relais per displacementem mechanicam diversarum systematum gear level efficitur.
In relais statico hoc principaliter fit per commutationes semiconductores ut thyristor. In relais digitali status on et off referuntur ut status 1 et 0.
Basati in characteristica, relais praesidii possunt categorizari ut:
Relais temporis definiti
Relais temporis inversi cum tempore minimo definito (IDMT)
Relais instantanei.
IDMT cum inst.
Characteristica graduata.
Commutores programmata.
Relais overcurrent cum restrictione voltage.
Basati in logica, relais praesidii possunt categorizari ut-
Differential.
Unbalance.
Displacement neutralis.
Directionalis.
Fault terrae restricta.
Over fluxing.
Schemata distantiae.
Praesidium bus bar.
Relais power reverse.
Loss of excitation.
Relais sequentiae phase negative etc.
Basati in parametro actuando, relais praesidii possunt categorizari ut-
Relais current.
Relais voltage.
Relais frequency.
Relais power etc.
Basati in applicatione, relais praesidii possunt categorizari ut-
Relais primarius.
Relais backup.
Relais primarius vel relais praesidii primarius est prima linea praesidii systematis electrici, dum relais backup operatur tantum quando relais primarius non operatur durante fault. Itaque relais backup tardius agit quam relais primarius. Quodlibet relais potest non operari propter unam ex sequentibus causis,
Ipsum relais praesidii defectuosum est.
Supply DC Trip voltage ad relais non disponibilis est.
Trip lead ab panel relais ad circuit breaker disjuncta est.
Trip coil in circuit breaker disjunctus est vel defectuosus est.
Signales current vel voltage a Current Transformers (CTs) vel Potential Transformers (PTs) respectiviter non disponibiles sunt.
Quia relais backup operatur tantum quando relais primarius non operatur, relais praesidii backup nihil commune debet habere cum relais praesidii primario.
Exempla relais mechanicorum sunt:
Thermal
OT trip (Oil Temperature Trip)
WT trip (Winding Temperature Trip)
Bearing temp trip etc.
Float type
Buchholz
OSR
PRV
Water level Controls etc.
Pressure switches.
Mechanical interlocks.
Pole discrepancy relay.
Nunc intuemur quae diversa relais praesidii utuntur in diversis schematibus praesidii equipmentum systematis electrici.
| SL | Lineae pro praesidio | Relais pro usu |
| 1 | 400 KV Linea Transmissionis |
Main-I: Non switched or Numerical Distance Scheme Main-II: Non switched or Numerical Distance Scheme |
| 2 | 220 KV Linea Transmissionis |
Main-I : Non switched distance scheme (Fed from Bus PTs) Main-II: Switched distance scheme (Fed from line CVTs) With a changeover facility from bus PT to line CVT and vice-versa. |
| 3 | 132 KV Linea Transmissionis |
Main Protection : Switched distance scheme (fed from bus PT). Backup Protection: 3 Nos. directional IDMT O/L Relays and 1 No. Directional IDMT E/L relay. |
| 4 | 33 KV lines | Non-directional IDMT 3 O/L and 1 E/L relays. |
| 5 | 11 KV lines | Non-directional IDMT 2 O/L and 1 E/L relays. |
| SL | Ratio Voltage et Capacitas Transformeris | Relais in HV Latus | Relais in LV Latus | Relais Communes |
| 1 | 11/132 KV Generator Transformer |
3 nos Non-Directional O/L Relay 1 no Non-Directional E/L Relay and/or standby E/F + REF Relay |
– – | Differential Relay or Overall differential Relay Overflux Relay Buchholz Relay OLTC Buchholz Relay PRV Relay OT Trip Relay WT Trip Relay |
| 2 | 13.8/220 KV 15.75/220 KV 18/400 KV 21/400 KV Generator Transformer |
3 nos Non-Directional O/L Relay 1 no Non-Directional E/L Relay
Donum da et auctorem hortare
SuggestusAccidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
02/05/2026
Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
01/30/2026
Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
01/29/2026
Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
01/29/2026
Inquiry
|