What is AC Bridge?

Edwiin
Edwiin
Field: Power switch
China

Definition of AC Bridge
An AC bridge is a specialized electrical instrument used for the pr

ecise measurement of unknown electrical parameters such as resistance, inductance, and capacitance. Renowned for its convenience and accuracy, the AC bridge plays a crucial role in various electrical engineering applications.
Construction and Working Principle
The construction of an AC bridge is relatively straightforward. It comprises four arms, an AC supply source, and a balance detector. The four arms of the bridge are typically configured with a combination of resistors, inductors, capacitors, or a mixture of these components. The AC supply source provides the necessary alternating - current excitation to the bridge circuit.
The operation of the AC bridge is based on the principle of impedance balance. When the bridge is in a balanced state, the ratio of the impedances in the two pairs of opposite arms of the bridge is equal. This balance condition results in zero voltage across the balance detector, often referred to as a null detector. By measuring the known components in the bridge arms and using the relationship between the impedances at the balance point, the values of the unknown resistance, inductance, or capacitance can be accurately determined.

General Equation for an AC Bridge
An AC bridge typically consists of four arms. In many common configurations, two of these arms are composed of non - inductive resistances, while the remaining two arms feature inductances with negligible resistance.
When the AC bridge attains a balanced state,

Analysis of AC Bridge Balance Equations

Let l1 and R1 represent the unknown parameters to be measured. These can be determined based on known values R2, R3, R4, and L2. Through an examination of equations (1) and (2), several key insights can be drawn:

Key Characteristics of AC Bridges

  1. Dual Balance Equations: AC bridges inherently yield two balance equations as a result of their circuit configuration. These equations are fundamental to the operation and analysis of the bridge, providing the necessary mathematical relationships for measurement.

  2. Parameter Determination: The unknown electrical quantities, which commonly include inductance, capacitance, and resistance, are calculated using these balanced equations. By substituting known values into the equations, engineers can accurately solve for the unknowns, enabling precise measurement of electrical components.

  3. Frequency - Independence: A notable feature of the balance equations derived from AC bridges is their independence from the frequency of the applied alternating current. This characteristic ensures consistent and reliable measurements across a wide range of frequencies, making AC bridges versatile tools in electrical engineering.

  4. Diverse Applications: Beyond their primary use in component measurement, AC bridges find extensive application in various other fields. They play a crucial role in communication systems, aiding in signal processing and impedance matching. Additionally, they are integral to complex electronic circuits, where their ability to measure and analyze electrical parameters contributes to the design, optimization, and troubleshooting of these systems.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is