Safety Rules For Overhead Lines

  • Nobody should climb any tower carrying live overhead conductors.

  • Cows or other domestic animals should not be tied with any tower legs and stay wires.

  • Nobody should be allowed to throw any metallic strip, metallic wire, ropes and green twinges to the live over head lines.

  • If any conductor is snapped or dangling from the tower, should not be touched without proper shutdown and temporary earthing arrangement. In this case nobody should be allowed to come closer to the snapped or hanged conductor until the entire circuit is isolated and earthed from both ends substations. In additions to that the snapped conductors should also be locally temporarily earthed with proper earthing rod before touching it for repairing work.

  • If we see any sparking on the live conducting parts of over head system, we should immediately inform to the concerned authority.

  • We should not put any temporary or permanent bands or embankments under the live over head line which is causes reduction in ground clearance of the Overhead line.

  • We should not carry any long metallic poles, bamboos, pipes etc below the live conductors. Farming just below the over head electrical lines are allowed but cultivation of sugarcanes like plants h be avoided if those grow above 5 meters height.

  • Over loaded bullock carts, tractors trail or similar kind of vehicle with height more than 5 meters from ground level should not cross any live over head lines.

  • Any building either temporary or permanent should not be constructed below the over head line. Not only below the over head lines, the building should also be constructed well away from the line by following standard electrical clearance rules of the country.

  • We should not touch any over head tower body during rain.

  • We should keep sufficient safe distance from the over head line during stormy weather. During storm, any line conductor or tower may accidentally fall on us.


Give a tip and encourage the author!

Recommended

Main Transformer Accidents and Light Gas Operation Issues
1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
02/05/2026
Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.