Optical Pyrometer | Construction and Working Principle

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Is A Optical Pyrometer

The working principle and construction of an Optical Pyrometer are quite simple. We have drawn an experimental model of this type of temperature sensors. It is a measuring instrument that measures temperature of a hot glowing object.

The instrument has an illuminated reference, with which the brightness of that of the hot body is matched by controlling the input electric current of the reference.

When, the glow of the reference matches with the hot object through an eye piece, that electric current is measured to calibrate the temperature of the hot body.

Construction of Optical Pyrometer

It is quite simple. Consider it as a cylinder, which has a lens in one end and in the other end there is an eye piece. In between there is a lamp. In front of the eye piece there is a colored glass (usually red), to make lights monochromatic. The lamp is connected to a battery source through an ammeter and a rheostat as shown in the figure.

The optical pyrometer works in a certain simple process. The process is, the brightness of the filament of the lamp, that we are using through a battery source can be controlled by the rheostat. Now by controlling the incoming current, the brightness of the filament is increased or decreased.

Going through this process there will be a certain point, when the filament of the lamp will not be visible from the eye piece. That very moment the brightness of the filament matches with the brightness of the hot body as seen through the monochromatic glass. From the reading of the ammeter of that particular condition we can get the temperature of the hot body, as the ammeter is previously calibrated in temperature scale.

Limitations of Optical Pyrometer

There are some limitations of this pyrometer. Such as:–

  1. This type of pyrometer can measure the temperature of only those objects which are emitting light that means glowing objects.

  2. The optical pyrometer has a range of measuring temperature of 1400oC to near about 3500oC.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
Complete Guide to Circuit Breaker Selection and Setting Calculation
Complete Guide to Circuit Breaker Selection and Setting Calculation
How to Select and Set Circuit Breakers1. Types of Circuit Breakers1.1 Air Circuit Breaker (ACB)Also known as a molded frame or universal circuit breaker, all components are mounted within an insulated metal frame. It is typically open-type, allowing easy replacement of contacts and parts, and can be equipped with various accessories. ACBs are commonly used as main power supply switches. Overcurrent trip units include electromagnetic, electronic, and intelligent types. They provide four-stage pro
Echo
10/28/2025
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
Basic Composition and Function of Circuit Breaker Failure ProtectionCircuit breaker failure protection refers to a protective scheme that operates when the relay protection of a faulty electrical device issues a trip command but the circuit breaker fails to operate. It uses the protection trip signal from the faulty equipment and the current measurement from the failed breaker to determine breaker failure. The protection can then isolate other relevant breakers within the same substation in a sh
Felix Spark
10/28/2025
 Electrical Room Power-On Safety Operation Guide
Electrical Room Power-On Safety Operation Guide
Power Supply Procedure for Low-Voltage Electrical RoomsI. Pre-Power-On Preparations Clean the electrical room thoroughly; remove all debris from switchgear and transformers, and secure all covers. Inspect busbars and cable connections inside transformers and switchgear; ensure all screws are tightened. Live parts must maintain adequate safety clearance from cabinet enclosures and between phases. Test all safety equipment before energizing; use only calibrated measuring instruments. Prepare fire-
Echo
10/28/2025
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
1 Key Points in Operation of High and Low Voltage Equipment1.1 High and Low Voltage EquipmentInspect insulating porcelain components for dirt, damage, or signs of electrical discharge. Check the exterior of low-voltage capacitor compensators for excessive temperature or bulging. If both conditions occur simultaneously, suspend installation work immediately. Examine wiring and terminal joints for oil leakage and conduct a thorough inspection for potential issues.Use auditory judgment to assess th
Felix Spark
10/28/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.