Thermocouple: Sensor Temperaturae Simplicis et Versatilis

Electrical4u
Campus: Electrica Elementaria
0
China

Quid est thermocouplum

Quid est thermocouplum?

Thermocouplum est instrumentum quod differentias temperaturarum in voltantia electrica convertit, secundum principium effectus thermoelectrici. Est genus sensoris quod temperaturam in loco specifico mensurare potest. Thermocouples latissime in variis campis, sicut industrialibus, domesticis, commercialibus et scientificis, propter simplicitatem, durabilitatem, parvum costum et amplam rangam temperaturarum, utuntur.

Quid est effectus thermoelectricus?

Effectus thermoelectricus est phenomenon generandi voltantiam electricam ex differentia temperaturarum inter duos metalla vel alloyes metallicas. Hunc effectum physicus Germanus Thomas Seebeck anno 1821 repperit, qui observavit campum magneticum creari circa circuitum clausum duorum dissimilium metallorum, cum una iunctura calefacta esset, alia vero refrixeretur.

Effectus thermoelectricus per motum electronorum liberiorum in metallis explicari potest. Cum una iunctura calefacta sit, electroni vim kineticam adipiscuntur et citius ad iuncturam frigidam moventur. Hoc potentialiter differentiam inter duas iuncturas creat, quae per voltmetrum vel ammeter mensurari potest. Magnitudo voltantis dependet a genere metallorum usitorum et differentia temperaturarum inter iuncturas.

Quomodo thermocouplum operatur?

Thermocouplum constat duobus filis ex diversis metallis vel alloyibus metallicis, iunctis ad utramque extremum ut formen duo iuncturas. Una iunctura, quae dicitur calida vel mensuralis, collocatur in loco ubi temperatura mensuranda est. Altera iunctura, quae dicitur frigida vel referens, tenetur ad constantem et notam temperaturam, saepe ad temperaturam ambientem vel in balneum glaciei.

Cum sit differentia temperaturarum inter duas iuncturas, voltantia electrica generatur per circuitum thermocoupli ex effectu thermoelectrico. Hanc voltantiam per voltmetrum vel ammeter ad circuitum connectum mensurare potest. Per tabulam calibrationis vel formulam quae relata sit voltanti ad temperaturam pro dato genere thermocoupli, temperaturam iuncturae calidae calculare potest.

Modus operandi thermocoupli

Sequens diagramma monstrat principium basicum modi operandi thermocoupli:

https://www.electrical4u.com/wp-content/uploads/Working-of-Thermocouple.png?ezimgfmt=rs:603x260/rscb38/ng:webp/ngcb38

Sequens video explicat modum operandi thermocoupli in maiore detexitate:

Quae sunt genera thermocouplorum?

Sunt multa genera thermocouplorum disponibilia, singula cum diversis characteribus et applicationibus. Genus thermocoupli determinatur ex combinatione metallorum vel alloyorum metallicorum ad fils usitorum. Genera thermocouplorum communissima litteris (sicut K, J, T, E, etc.) designantur secundum standards internationales.

Codex colorum thermocouplorum

Sequens tabula summarizat quaedam principia genera thermocouplorum et earum proprietates:

Genus Fili positivi Fili negativi Codex colorum Rangus temperaturarum Sensibilitas Accuratia Applicationes
K Niccolum-chromium (90% Ni, 10% Cr) Niccolum-aluminum (95% Ni, 2% Al, 2% Mn, 1% Si) Flavus (+), Ruber (-), Flavus (overall) -200°C ad +1260°C (-328°F ad +2300°F) 41 µV/°C ±2.2°C (0.75%) Propositum commune, rangus latus, parvum costum
J Ferrum (99.5% Fe) Constantan (55% Cu, 45% Ni) Albus (+), Ruber (-), Niger (overall) -210°C ad +750°C (-346°F ad +1400°F) 50 µV/°C ±2.2°C (0.75%) Atmosphaerae oxidantes, rangus limitatus
T Cuprum (99.9% Cu) Constantan (55% Cu, 45% Ni) Caeruleus (+), Ruber (-), Brunneus (overall) -200°C ad +350°C (-328°F ad +662°F) 43 µV/°C ±1°C (0.75%) Temperaturae bassae, atmosphaerae oxidantes
E Niccolum-chromium (90% Ni, 10% Cr) Constantan (55% Cu, 45% Ni) Purpureus (+), Ruber (-), Purpureus



| E | Niccolum-chromium (90% Ni, 10% Cr) | Constantan (55% Cu, 45% Ni) | Purpureus (+), Ruber (-), Purpureus (overall) | -200°C ad +870°C (-328°F ad +1598°F) | 68 µV/°C | ±1.7°C (0.5%) | Alta accuratia, moderatus rangus, parvum costum | | N | Nicrosil (84.1% Ni, 14.4% Cr, 1.4% Si, 0.1% Mg) | Nisil (95.5% Ni, 4.4% Si, 0.1% Mg) | Aurantium (+), Ruber (-), Aurantium (overall) | -200°C ad +1300°C (-328°F ad +2372°F) | 39 µV/°C | ±2.2°C (0.75%) | Propositum commune, rangus latus, stabilis | | S | Platinum-rhodium (90% Pt, 10% Rh) | Platinum (100% Pt) | Niger (+), Ruber (-), Viridis (overall) | 0°C ad +1600°C (+32°F ad +2912°F) | 10 µV/°C | ±1.5°C (0.25%) | Alta temperaturae, alta accuratia, carum | | R | Platinum-rhodium (87% Pt, 13% Rh) | Platinum (100% Pt) | Niger (+), Ruber (-), Viridis (overall) | 0°C ad +1600°C (+32°F ad +2912°F) | 10 µV/°C | ±1.5°C (0.25%) | Alta temperaturae, alta accuratia, carum | | B | Platinum-rhodium (70% Pt, 30% Rh) | Platinum-rhodium (94% Pt, 6% Rh) | Griseus (+), Ruber (-), Griseus (overall) | +600°C ad +1700°C (+1112°F ad +3092°F) | 9 µV/°C | ±0.5% lectionis supra +600°C (+1112°F) | Altissima temperaturae, bassa sensitivitas |

Quae sunt commoditates et incommoditates thermocouplorum?

Thermocoupli multas commoditates et incommoditates comparantur ad alios sensores temperaturarum, sicut RTDs (Detector Temperaturarum

Donum da et auctorem hortare

Suggestus

Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
01/30/2026
Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
01/29/2026
Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
01/29/2026
HECI GCB for Generators – Cepus SF₆ Circuit Breaker
1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
01/06/2026
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum