Strain Gauge: Working Principle & Diagram

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Is A Strain Gauge

What is a Strain Gauge

A strain gauge is a resistor used to measure strain on an object. When an external force is applied on an object, due to which there is a deformation occurs in the shape of the object. This deformation in the shape is both compressive or tensile is called strain, and it is measured by the strain gauge. When an object deforms within the limit of elasticity, either it becomes narrower and longer or it become shorter and broadens. As a result of it, there is a change in resistance end-to-end.

The strain gauge is sensitive to that small changes occur in the geometry of an object. By measuring the change in resistance of an object, the amount of induced stress can be calculated.

The change in resistance normally has very small value, and to sense that small change, strain gauge has a long thin metallic strip arrange in a zigzag pattern on a non-conducting material called the carrier, as shown below, so that it can enlarge the small amount of stress in the group of parallel lines and could be measured with high accuracy. The gauge is literally glued onto the device by an adhesive.

When an object shows physical deformation, its electrical resistance gets change and that change is then measured by gage.
strain gauge

Strain Gauge Bridge Circuit

Strain gauge bridge circuit shows the measured stress by the degree of discrepancy, and uses a voltmeter in the center of the bridge to provide an accurate measurement of that imbalance:

strain gauge bridge circuit

In this circuit, R1 and R3are the ratio arms equal to each other, and R2 is the rheostat arm has a value equal to the strain gage resistance. When the gauge is unstrained, the bridge is balanced, and voltmeter shows zero value. As there is a change in resistance of strain gauge, the bridge gets unbalanced and producing an indication at the voltmeter. The output voltage from the bridge can be amplified further by a differential amplifier.

Variation of Temperature of Strain Gauge

One more factor that affects the resistance of the gauge is temperature. If the temperature is more resistance will be more and if the temperature is less the resistance will be less. This is a common property of all the conductors. We can overcome this problem by using strain gauges that are self- temperature-compensated or by a dummy strain gauge technique.

Most of the strain gauges are made of constantan alloy which cancel out the effect of temperature on the resistance. But some strain gauges are not of an isoelastic alloy. In such cases, dummy gauge is used in the place of R2 in the quarter bridge strain gauge circuit which acts as a temperature compensation device.

Whenever temperature changes, the resistance will change in the same proportion in the both arms of the rheostat, and the bridge remains in the state of balance. Effect of temperature get nullifies. It is good to keep voltage low so that the self-heating of strain gauge could be evaded. Self-heating of gauge depends upon its mechanical behavior.
variation of temperature of strain gauge
This arrangement is considered as quarter-bridge. There are two more arrangements half-bridge and full-bridge configurations which give greater sensitivity over the quarter-bridge circuit. Still the quarter-bridge circuit is widely used in strain measurement systems.

Use of Strain Gauge

  • In the field of mechanical engineering development.

  • To measure the stress generated by machinery.

  • In the field of component testing of aircraft like; linkages, structural damage etc.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
PT Fuse Slow Blow: Causes, Detection & Prevention
PT Fuse Slow Blow: Causes, Detection & Prevention
I. Fuse Structure and Root Cause AnalysisSlow Fuse Blowing:From the design principle of fuses, when a large fault current passes through the fuse element, due to the metal effect (certain refractory metals become fusible under specific alloy conditions), the fuse first melts at the soldered tin ball. The arc then rapidly vaporizes the entire fuse element. The resulting arc is quickly extinguished by quartz sand.However, due to harsh operating environments, the fuse element may age under the comb
Edwiin
10/24/2025
Why Fuses Blow: Overload, Short Circuit & Surge Causes
Why Fuses Blow: Overload, Short Circuit & Surge Causes
Common Causes of Fuse BlowingCommon reasons for fuse blowing include voltage fluctuations, short circuits, lightning strikes during storms, and current overloads. These conditions can easily cause the fuse element to melt.A fuse is an electrical device that interrupts the circuit by melting its fusible element due to heat generated when current exceeds a specified value. It operates on the principle that, after an overcurrent persists for a certain period, the heat produced by the current melts
Echo
10/24/2025
Fuse Maintenance & Replacement: Safety and Best Practices
Fuse Maintenance & Replacement: Safety and Best Practices
1. Fuse MaintenanceFuses in service should be regularly inspected. The inspection includes the following items: Load current should be compatible with the rated current of the fuse element. For fuses equipped with a fuse blown indicator, check whether the indicator has actuated. Check the conductors, connection points, and the fuse itself for overheating; ensure connections are tight and making good contact. Inspect the fuse exterior for cracks, contamination, or signs of arcing/discharge. Liste
James
10/24/2025
Maintenance and Repair Items for 10kV High-Voltage Switchgear
Maintenance and Repair Items for 10kV High-Voltage Switchgear
I. Routine Maintenance and Inspection(1) Visual Inspection of Switchgear Enclosure No deformation or physical damage to the enclosure. Protective paint coating shows no severe rust, peeling, or flaking. Cabinet is securely installed, clean on the surface, and free of foreign objects. Nameplates and identification labels are neatly affixed and not falling off.(2) Check of Switchgear Operating Parameters Instruments and meters indicate normal values (comparable to typical operating data, with no s