Pangangalap ng disenyo para sa thermal management ng pad-mounted transformers

Dyson
Dyson
Larangan: Pamantayan sa Elektrisidad
China

Sa aktwal na operasyon, ang mga pad-mounted transformers ay nakakaranas ng mga karaniwang problema na may kaugnayan sa init:

  • Mataas na temperatura/mataas na load trips: Madaling mag-trip sa ilalim ng patuloy na mataas na temperatura at mataas na load na kondisyon.

  • Pagsira ng pana at thermostat: Ang matagal na paggamit ng pana ay nagdudulot ng mali, nagdudulot ng pinsala sa thermostat at nagbabara ng paglabas ng mainit na hangin, nagdudulot ng pagkakabigla-bigla sa operasyon.

  • Mahirap na lokasyon ng pana: Ang pag-mount ng pana sa itaas ng kabinet ay nangangailangan ng pag-off ng power para sa pag-maintain/pagpalit; ang layout na ito ay dinadala rin ng init, nagpapataas ng indoor temperature sa antas ng panganib ng scalding.

Upang i-optimize ang paglabas ng init, ang papel na ito ay gumagamit ng finite element analysis upang lumikha ng 3D transformer model. Sa pamamagitan ng pag-map ng distribusyon ng temperature field, ito ay natutukoy ang mga hotspots ng sobrang init at inaayos ang disenyo ng cooling system.

1. Mga Pangunahing Konsepto ng Temperature Field

Ang temperature field ay naglalarawan ng mga pagbabago ng temperatura sa espasyo at oras, na may malapit na ugnayan sa paglikha, paglipat, at distribusyon ng init. Para sa pad-mounted transformers, ang init ay nanggagaling sa cores, windings, atbp. Ang mga kondisyon ng operasyon/durasyon ay nagbabago ng mga pattern ng init, at ang multi-medium interactions (cores, windings, insulation) ay naglilikha ng hindi pantay na distribusyon ng temperatura.

Ang init ay nalilipat sa pamamagitan ng conduction (dominant, nagpapadala ng init mula sa windings/cores sa pamamagitan ng insulating resin patungo sa hangin ng paligid) at convection. Ang lakas ng conduction ay nauugnay sa mga gradient ng temperatura—ang init ay lumilipat mula sa mga mainit na bahagi patungo sa mas lamig na resin, at pagkatapos ay nalilipat sa external air. Ang mga kalkulasyon ng heat flux ay sumusunod:

Sa formula: q represents the heat flux density;λ represents the thermal conductivity; ∂t/∂x is the temperature gradient, reflecting the rate of temperature change with distance; n is the heat conversion coefficient. When there are temperature differences at different positions, heat mainly circulates to balance the temperature, and this state of temperature balance is heat convection. During the operation of a pad - mounted transformer, the heat generated by various parts will come into contact with air and transfer between them, causing changes in the temperature of the surrounding gas. During this process, heat transfer is achieved through heat convection, which can be expressed by the following formula:

Sa formula, h ang convective heat transfer coefficient, tf represents the fluid temperature, and tw represents the temperature of the objects surface. When the temperature of an object is higher than absolute zero, radiant heat will be generated, usually called thermal radiation. With other factors remaining unchanged, the amount of radiation generated between objects will change as the temperature rises (with the temperature maintaining a continuous upward trend). During the operation of a pad - mounted transformer, the equipment itself does not come into direct contact with thermal radiation; when the temperature of the transformer stabilizes, its thermal radiation function will achieve heat dissipation through thermal radiation, and this process can be expressed by the following formula:

Sa formula, S denotes the radiation surface area, T is the thermodynamic temperature of the object, and σ is the radiation constant. When designing the heat dissipation system for pad - mounted transformers, the finite element analysis (FEA) method is primarily employed to establish thermal equilibrium equations. Through calculations, the temperature at each node of the object can be determined. This is particularly useful for measuring temperature points that are difficult to obtain in practice, identifying optimal hotspot locations, and then conducting coupling analysis. The core principles of decomposing the temperature field using FEA are as follows:

  • Discretize the three - dimensional physical domain;

  • Use functions to describe the temperature variations at any node within the element;

  • Construct element equations;

  • Assemble the elements and apply external excitations at the nodes;

  • Solve the equations by considering the temperature field boundary conditions;

  • Calculate the temperature rise at each node;

  • Derive the element temperature rise based on the temperature field equations.

2 Modeling and Temperature Field Simulation of Pad - Mounted Transformers
2.1 Finite Element Modeling

Table 1 lists the relevant parameters of the pad - mounted transformer selected in this paper. A finite element model is constructed based on these parameters. Subsequently, simplified models are established for the high - voltage winding, low - voltage winding, and iron core of the pad - mounted transformer.

During model construction, since the welded connections of the high - voltage winding outlet terminals are relatively firm, they are not taken into account in the initial design phase. For simplification, the iron core is modeled as a monolithic structure, with inter - laminar gaps ignored (these gaps are addressed by means of the properties of bulk silicon steel to account for the material conductivity). The 3D simulation model of the transformer is shown in Figure 1.

To analyze the effects of natural convection on heat dissipation, an external air domain (with dimensions of 5000mm×5000mm×3000mm) is added to the simulation environment, enabling realistic modeling of the airflow patterns around the transformer.

2.2 Enclosure Model of Pad-Mounted Transformer

The windings and iron core are modeled as heat sources, with their heat generation rates calculated based on transformer design parameters. The air domain is configured with pressure outlets at the top and inlets distributed along the bottom and sides, maintaining an ambient temperature set at 300K. During simulations, natural convection parameters are derived by selecting an appropriate turbulence model based on the Rayleigh number.

The enclosure geometry (Figure 2) is simplified due to its complex composite structure. The roof's perforated panels are neglected, treating the entire roof as a continuous air domain. Porous media are placed at the air outlets under the eaves to simulate flow resistance. The air domain around the enclosure's bottom support beams is considered interconnected. An additional 155mm - high air layer is added beneath the enclosure to account for the foundation's impact on heat dissipation.

In the established model, the pre - set bottom holes, top holes, and upper - lower holes all belong to porous media, with a thickness of 10 mm (such as the yellow - green block in Figure 3), thus simulating the mesh plate. The specification of the bottom hole is 1450 × 1200 mm², and the specification of the upper - lower holes is 550 × 500 mm². Three openings and an epoxy plate are also set in the model, and the openings are determined to be in an open or closed state according to the actual situation. Generally, if the floor - mounted type is adopted, the top hole, the epoxy plate, and Opening 1 are in an open state; if the bottom - holed type is adopted, the top hole, the bottom hole, and Openings 1/2/3 are all in an open state.

2.3 Temperature Field Distribution Analysis

Next, a finite element model is built by meshing the geometric model. Ensure unity of natural convection and internal mesh models, and refine meshing at enclosure holes and air interfaces to improve calculation accuracy. Based on the geometric model, the finite element model has 401,856 nodes and 518,647 meshes. Key settings for the pad - mounted transformer model:

  • Fluid - structure interface: Air interface, no - slip state for heat conservation.

  • Adiabatic surfaces: Top of the roof, sides of bottom support beams, and external air.

  • Heat - conducting surfaces: Enclosure sides (1mm - thick steel plate), all enclosure walls (2mm - thick steel plate), with upper holes open and lower holes closed.

Using finite element software, the temperature field model shows: Windings have the highest temperature in the transformer, followed by the iron core; adjacent air temperature is also high, decreasing during air rise until matching ambient temperature at the pressure outlet. During operation, hot air expansion causes air accumulation and collisions between ambient and duct air (due to continuous heating and volume increase). Air viscosity affects duct flow and the flow field. Hot air accelerates near the ground and slows away; airflow - surface contact forms a thermal boundary layer, which, due to its thickness, reduces heat transfer coefficients, increasing temperature and air viscosity while decreasing flow velocity. Hot air alters the temperature above the transformer, with temperature proportional to thermal radiation.

3 Heat Dissipation Design of Pad - Mounted Transformers
3.1 Model Analysis

Pad - mounted transformers are arranged inside enclosures with a high safety level. To ensure smooth air circulation within the enclosure and give full play to the transformer's heat dissipation performance, axial flow fans need to be configured to discharge hot air from the equipment interior. Meanwhile, heat sinks are installed outside the enclosure to achieve heat exchange. Through heat exchange, the continuous circulation of air inside the transformer can be promoted.

During the operation of pad - mounted transformers, heat is mainly generated by windings and iron cores. Therefore, the design needs to focus on the air flow states of these two components and integrate the relevant elements for building the heat dissipation model.

3.2 Determination of Model Parameters

For pad - mounted transformers, the differences between indoor air parameters and temperature performance parameters are relatively small. When selecting silicon steel sheets, their heat resistance performance should be prioritized. Meanwhile, the numerical ratio of copper wires to insulating resin is analyzed to determine the thermal performance parameters.

3.3 Condition Setting

The average pressure at the air inlet and outlet of the pad - mounted transformer is one atmospheric pressure. Combined with the performance of the heat sink, the temperature of cold air is taken as the inlet condition to establish a finite element model, and the symmetry plane and air inlet - outlet direction are defined.

3.4 Result Analysis

After establishing the model and setting the boundary conditions, calculations are carried out. The analysis shows that the air outlet of the pad - mounted transformer is the hottest point, with a temperature reaching 394.5K (corresponding to a hot - spot temperature of 120.5℃). The hottest point of the iron core is far from the air outlet, and the calculated hot - spot temperature is 110℃. Moreover, the positions close to the air inlets and outlets have poor heat dissipation performance.

3.5 Inlet and Outlet Air Analysis

Simulate the change of air flow velocity: If the hot high - voltage winding is built - in close to the air outlet and the air outlet has a right - angle structure, it will affect the air pressure, making the air inside the encapsulation thin and unfavorable for heat dissipation.

Based on this, optimize the air outlet design: Move the air outlet upward by about 30cm, keep the height unchanged, and simultaneously reduce the width of the air inlet (mainly reduce by 10cm), so that the overall length of the enclosure increases by 20cm. After calculation, under this scheme, the hot - spot temperature and average temperature of the winding decrease significantly. Analyzing the air flow field velocity distribution, the winding air flow shows a 120° angle when transferred to the air outlet, indicating that the air flow is smooth.

3.6 Summary

Pad - mounted transformers play a crucial role in the power distribution system. If the large amount of heat generated during operation cannot be dissipated in a timely manner, it is likely to cause failures and threaten the stability of the system. Designers need to deeply analyze the heat dissipation problems of pad - mounted transformers, combine with the changes of the temperature field, use scientific methods such as the finite element method to build heat dissipation models, optimize the equipment's heat dissipation system, and improve the overall heat dissipation efficiency.

Magbigay ng tip at hikayatin ang may-akda!
Inirerekomenda
Pinakamababang Operating Voltage para sa Vacuum Circuit Breakers
Pinakamababang Operating Voltage para sa Vacuum Circuit Breakers
Pinakamababang Voltaje para sa Trip at Close Operations sa Vacuum Circuit Breakers1. PagkakataonKapag narinig mo ang termino "vacuum circuit breaker," maaaring hindi ito kilala. Ngunit kung sasabihin natin "circuit breaker" o "power switch," marami ang marunong dito. Sa katunayan, ang mga vacuum circuit breakers ay mahalagang komponente sa modernong sistema ng enerhiya, na may tungkulin na protektahan ang mga circuit mula sa pinsala. Ngayon, susuriin natin ang isang mahalagang konsepto — ang pin
Dyson
10/18/2025
Sistema ng IoT na Pinapagana ng Hybrid na Wind-Solar para sa Real-Time na Pagmomonito ng Tubig Pipeline
Sistema ng IoT na Pinapagana ng Hybrid na Wind-Solar para sa Real-Time na Pagmomonito ng Tubig Pipeline
I. Kasalukuyang Kalagayan at Umumang mga ProblemaSa kasalukuyan, ang mga kompanya ng pagbibigay ng tubig ay may malawak na mga network ng mga linya ng tubig na inilapat sa ilalim ng lupa sa mga urban at rural na lugar. Mahalaga ang real-time monitoring ng datos ng operasyon ng pipeline para sa epektibong pamamahala at kontrol ng produksyon at distribusyon ng tubig. Dahil dito, kailangan mabuo ang maraming istasyon ng pag-monitor ng datos sa buong mga linya. Gayunpaman, bihira ang matatag at maas
Dyson
10/14/2025
Paano Gumawa ng Isang Intelligent Warehouse System Batay sa AGV
Paano Gumawa ng Isang Intelligent Warehouse System Batay sa AGV
Intelligent Warehouse Logistics System Based on AGVSa mabilis na pag-unlad ng industriya ng logistics, paglaki ng kakulangan sa lupa, at pagtaas ng mga gastos sa pagsasakahan, ang mga warehouse—bilang pangunahing hub ng logistics—ay nasa harap ng malaking hamon. Habang ang mga warehouse ay naging mas malaki, ang frequency ng operasyon ay tumataas, ang komplikadong impormasyon ay lumalaki, at ang mga gawain sa pagkuha ng order ay naging mas mahirap, ang pagkamit ng mababang rate ng error at pagba
Dyson
10/08/2025
Paano Papanatiliin ang Optimal na Performance ng mga Instrumentong Elektrikal
Paano Papanatiliin ang Optimal na Performance ng mga Instrumentong Elektrikal
1 Mga Sira sa Instrumento ng Elektrisidad at Pagmamanila1.1 Mga Sira at Pagmamanila ng Meter ng ElektrisidadSa paglipas ng panahon, maaaring mabawasan ang katumpakan ng mga meter ng elektrisidad dahil sa pagluma ng mga komponente, pagsusubok, o pagbabago ng kapaligiran. Ang pagbawas ng katumpakan na ito ay maaaring magresulta sa hindi tama na pagsukat, nagdudulot ng pagkawala ng pera at mga pagtatalo para sa mga gumagamit at kompanya ng suplay ng kuryente. Bukod dito, ang panlabas na pangangaila
Felix Spark
10/08/2025
Inquiry
I-download
Kumuha ng IEE-Business Application
Gamit ang app na IEE-Business upang makahanap ng kagamitan makuha ang mga solusyon makipag-ugnayan sa mga eksperto at sumama sa industriyal na pakikipagtulungan kahit kailan at saanman buong pagsuporta sa pag-unlad ng iyong mga proyekto at negosyo sa enerhiya