DC Generators Performance Curves

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Performance Curves Definition

Performance curves of a DC generator are graphs that show how the output voltage changes as the load current varies from no load to full load. These are also known as characteristic curves. These curves help us understand the voltage regulation of different types of DC generators. Better performance is indicated by lower voltage regulation.

Separately Excited DC Generator

Though this type of DC generators are rarely used due to its cost for the separate excitation but the performance of these DC generators are quite satisfactory. In separately excited DC generators, the terminal voltage as the load increases and the load current started to flow.

There is slight drop in the terminal voltage due to armature reaction and IR drop but these drop can be eliminated by increasing field excitation and then we can get constant terminal voltage. In the diagram below, the curve AB is showing this characteristic.

Series Wound DC Generator

In series DC generators, the terminal voltage at no load is zero because no current flows through the field winding. As the load increases, the output voltage rises. The terminal voltage varies widely with small changes in load current. Due to armature reaction and ohmic drop in the armature winding, the output voltage is lower than the generated voltage.

Shunt Wound DC Generator

In shunt wound DC generators, there is always some voltage at no load due to the shunt field winding. As the load increases, the terminal voltage drops quickly because of strong demagnetizing armature reaction and resistance drop. This drastic reduction in terminal voltage leads to a decrease in load current, resulting in poor performance of this type of generators.

Compound Wound DC Generator

At no load, the performance curve of this type of DC generator is same as that of shunt field generators because at no load, there is no current in the series field winding. When the load increases, then the terminal voltage drops due to the shunt DC generator, but the voltage rise in the series DC generator compensates the voltage drop. For these reason the terminal voltage remains constant. The terminal voltage can also make higher or lower by controlling the amp-turns of the series field winding. In the diagram below, the curve FG is showing this characteristic.

a08420d0433e6d6f7a185f2e38d71b7d.jpeg


Give a tip and encourage the author!
Recommended
How to Choose & Maintain Electric Motors: 6 Key Steps
How to Choose & Maintain Electric Motors: 6 Key Steps
"Selecting a High-Quality Motor" – Remember the Six Key Steps Inspect (Look): Check the motor’s appearanceThe motor’s surface should have a smooth, even paint finish. The nameplate must be properly installed with complete and clear markings, including: model number, serial number, rated power, rated current, rated voltage, allowable temperature rise, connection method, speed, noise level, frequency, protection rating, weight, standard code, duty type, insulation class, manufacturing date, and ma
Felix Spark
10/21/2025
 What Is the Working Principle of a Power Plant Boiler?
What Is the Working Principle of a Power Plant Boiler?
The working principle of a power plant boiler is to utilize the thermal energy released from fuel combustion to heat feedwater, producing a sufficient quantity of superheated steam that meets specified parameters and quality requirements. The amount of steam produced is known as the boiler's evaporation capacity, typically measured in tons per hour (t/h). Steam parameters primarily refer to pressure and temperature, expressed in megapascals (MPa) and degrees Celsius (°C), respectively. Steam qua
Edwiin
10/10/2025
What is the principle of live-line washing for substations?
What is the principle of live-line washing for substations?
Why Do Electrical Equipment Need a "Bath"?Due to atmospheric pollution, contaminants accumulate on insulating porcelain insulators and posts. During rain, this can lead to pollution flashover, which in severe cases may cause insulation breakdown, resulting in short circuits or grounding faults. Therefore, the insulating parts of substation equipment must be periodically washed with water to prevent flashover and avoid insulation degradation that could lead to equipment failure.Which Equipment Is
Encyclopedia
10/10/2025
Essential Dry-Type Transformer Maintenance Steps
Essential Dry-Type Transformer Maintenance Steps
Routine Maintenance and Care of Dry-Type Power TransformersDue to their flame-resistant and self-extinguishing properties, high mechanical strength, and ability to withstand large short-circuit currents, dry-type transformers are easy to operate and maintain. However, under poor ventilation conditions, their heat dissipation performance is inferior to that of oil-immersed transformers. Therefore, the key focus in the operation and maintenance of dry-type transformers is controlling the temperatu