Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Sag and Tension
For safety purpose, the ground clearance of the conductors at maximum temperature and minimum loading condition should be maintained. Analysis of the sag and tension is important in the transmission line for the continuity and quality of electrical services. If the tension of the conductor is increased beyond the limit, it may get broken, and the power transmission of the system get erupt.The dip of the conductor between the two level supports is called sag. In other words, the vertical distance
05/13/2025
Consult
Tip
Consult
Tip
Stranded Wire vs. Solid Wire: Which One is Better and Why?
What is Stranded Wire?A stranded wire consists of multiple thin strands of conductors bundled together, often with each pair of strands twisted and insulated. These wires come in various sizes tailored to specific applications.In the UK, common wire sizes are denoted in formats such as 3/0.029″, 7/0.036″, and 7/0.042″. Here, the first digit (e.g., 3 or 7) indicates the number of individual stranded conductors, while the second part (e.g., 0.029″, 0.042&
05/13/2025
Consult
Tip
Consult
Tip
Typical sensor and control location in GIS according to IEC 61850
Arrangement and Communication of GIS Control ElementsThe positioning of control and communication components in Gas - Insulated Switchgear (GIS) can differ significantly based on the design choices of various manufacturers.As illustrated in the accompanying figure, a typical configuration of GIS integrating switchgear controllers and communication elements features a circuit breaker controller (CBC) and a disconnector or earth switch controller (DCC) tailored for a three - phase pole setup. The
05/13/2025
Consult
Tip
Consult
Tip
Why is Power Transmitted at High Voltage Instead of High Current?
The Rationale Behind High-Voltage, Low-Current Power TransmissionFor long-distance power transmission, sending electrical power at high voltage and low current stands as the most efficient and cost-effective strategy. This approach significantly mitigates resistive losses, reduces the reliance on costly conductors, and enhances the overall performance of the electrical grid. In this article, we will delve into the key reasons why high-voltage transmission is favored over low-voltage or high-curr
05/12/2025
Consult
Tip
Consult
Tip
Classification of Substations
Substations: An Overview of Power Transfer HubsA substation serves as a crucial intermediary in the power delivery process, facilitating the transfer of electrical energy from the generation source to end - users. It is equipped with various essential components, including transformers, generators, and power cables, all of which play integral roles in ensuring efficient power transmission. The core functions of a substation encompass power generation, transmission, and distribution.Substations t
05/12/2025
Consult
Tip
Consult
Tip
 Indoor Substation
An indoor substation refers to a type of substation where all apparatus is installed within the substation building. Typically, this kind of substation is designed for voltages up to 11,000 volts. However, in environments where the surrounding air is contaminated by substances such as metal - corroding gases, fumes, and conductive dust, its applicable voltage range can be extended to 33,000 to 66,000 volts.As illustrated in the diagram below, an indoor substation is divided into multiple compart
05/12/2025
Consult
Tip
Consult
Tip
Outdoor Substation
An outdoor substation is one that accommodates all voltage levels ranging from 55 KV to 765 KV. This type of substation generally requires less construction time but occupies more space. Outdoor substations are primarily categorized into two types: pole - mounted substations and foundation - mounted substations.Pole - Mounted SubstationPole - mounted substations are utilized to support distribution transformers with a capacity of up to 250 KVA. These transformers are among the most cost - effect
05/12/2025
Consult
Tip
Consult
Tip
Oil Filled Cables
DefinitionAn oil - filled cable is defined as a cable where low - viscosity oil is maintained under pressure, either within the cable sheath itself or in a containing pipe. Under all conditions of varying loads, the oil in the cable fills the voids in the oil - impregnated paper. Historically, mineral oils were commonly used, but more recently, alkylates such as linear decyl benzene and branched nonyl benzene have gained popularity. This is due to their low viscosity and their ability to absorb
05/12/2025
Consult
Tip
Consult
Tip
What are Line Supports?
DefinitionLine supports refer to various structures, such as poles or towers, that are employed to uphold overhead power lines or wires. These structures play a crucial role in power transmission. They ensure appropriate spacing between conductors and maintain a prescribed distance between the conductors and grounded components. Additionally, they uphold the specified ground clearance, which is determined by electrical and mechanical considerations.Types of Line SupportsThe key requisites for li
05/12/2025
Consult
Tip
Consult
Tip
Digitalicition example based by IEC 61850 in medium voltage switchgear
The utilization of Rogowski coils for current measurements, voltage dividers for voltage measurements, and a digital bus for sharing switchgear events and sampled measured values enables the separation of measuring hardware engineering from protection applications. This decoupling enhances flexibility and efficiency in electrical system design and operation.For the protection functions of each Intelligent Electronic Device (IED), line - to - ground currents are consistently measured separately i
05/12/2025
Consult
Tip
Consult
Tip