Outdoor Substation

Edwiin
Edwiin
Field: Power switch
China

An outdoor substation is one that accommodates all voltage levels ranging from 55 KV to 765 KV. This type of substation generally requires less construction time but occupies more space. Outdoor substations are primarily categorized into two types: pole - mounted substations and foundation - mounted substations.

Pole - Mounted Substation

Pole - mounted substations are utilized to support distribution transformers with a capacity of up to 250 KVA. These transformers are among the most cost - effective, simplest, and smallest in distribution systems. All the equipment in such substations is of the outdoor type and is mounted on the supporting structures of the high - tension distribution line. A triple - pole mechanically operated switch is employed to switch the high - tension transmission line on and off.

An HT (High Tension) fuse provides protection for the high - tension transmission line. For controlling low - tension lines, low - tension switches accompanied by fuses are installed. Lightning arresters are placed on the high - tension line to safeguard the transformers from voltage surges. Pole - mounted substations are earthed at two or more locations for safety.

Transformers with a capacity of up to 125 KVA are mounted on a double - pole structure. For transformers with a capacity ranging from 125 to 250 KVA, a 4 - pole structure with an appropriate platform is utilized. These substations are typically situated in densely populated areas.

Their maintenance cost is relatively low. In a town, deploying a large number of such substations allows for the installation of distributors at a lower cost. However, as the number of transformers increases, the total KVA rises, leading to an increase in no - load losses and an uptick in the cost per KVA.

Foundation - Mounted Substation

In a foundation - mounted substation, all the equipment is assembled, and the substation is surrounded by a fence for safety. The equipment required for this type of substation is heavy. Therefore, the site chosen for a foundation - mounted substation must have a suitable route for heavy - duty transportation. An illustration of a foundation - mounted outdoor substation is provided below.

Transformers with a capacity of up to 125 KVA are mounted on a double - pole structure. For transformers with a capacity ranging from 125 to 250 KVA, a 4 - pole structure with an appropriate platform is utilized. These substations are typically situated in densely populated areas.

Their maintenance cost is relatively low. In a town, deploying a large number of such substations allows for the installation of distributors at a lower cost. However, as the number of transformers increases, the total KVA rises, leading to an increase in no - load losses and an uptick in the cost per KVA.

In a foundation - mounted substation, all the equipment is assembled, and the substation is surrounded by a fence for safety. The equipment required for this type of substation is heavy. Therefore, the site chosen for a foundation - mounted substation must have a suitable route for heavy - duty transportation. An illustration of a foundation - mounted outdoor substation is provided below.

Advantages of Outdoor Substations

Outdoor substations offer several key advantages:

  • Easier Fault Detection: All equipment in outdoor substations is visible, which simplifies the process of locating faults.

  • Simplified Expansion: Expanding the installation is more straightforward compared to indoor counterparts.

  • Faster Construction: These substations require less time to construct.

  • Lower Material Requirement: They demand a relatively small quantity of building materials such as steel and concrete.

  • Reduced Construction and Installation Costs: The construction work is comparatively less extensive, and the cost of switchgear installation is also quite low.

  • Convenient Repair and Isolation: Repair work is easy to carry out. Adequate space between apparatus ensures that a fault at one location doesn't spread to other components.

Disadvantages of Outdoor Substations

  • Higher Space Requirement: Outdoor substations necessitate a larger area.

  • Need for Surge Protection: Protection devices must be installed to safeguard against lightning surges.

  • Increased Cable Costs: The length of control cables is greater, which raises the overall cost of the substation.

  • Higher Equipment Cost: Equipment designed for outdoor use is more expensive since it needs additional protection against dirt and dust.

Despite these drawbacks, outdoor substations are widely employed in power systems.

Give a tip and encourage the author!
Topics:
Recommended
How Does Oil Loss Affect SF6 Relay Performance?
How Does Oil Loss Affect SF6 Relay Performance?
1.SF6 Electrical Equipment and the Common Problem of Oil Leakage in SF6 Density RelaysSF6 electrical equipment is now widely used in power utilities and industrial enterprises, significantly advancing the development of the power industry. The arc-quenching and insulating medium in such equipment is sulfur hexafluoride (SF6) gas, which must not leak. Any leakage compromises the reliable and safe operation of the equipment, making it essential to monitor the SF6 gas density. Currently, mechanical
Felix Spark
10/21/2025
MVDC: Future of Efficient, Sustainable Power Grids
MVDC: Future of Efficient, Sustainable Power Grids
The Global Energy Landscape Is Undergoing a Fundamental Transformation toward a "fully electrified society," characterized by widespread carbon-neutral energy and the electrification of industry, transportation, and residential loads.In today’s context of high copper prices, critical mineral conflicts, and congested AC power grids, Medium-Voltage Direct Current (MVDC) systems can overcome many limitations of traditional AC networks. MVDC significantly enhances transmission capacity and efficienc
Edwiin
10/21/2025
Grounding Causes of Cable Lines and the Principles of Incident Handling
Grounding Causes of Cable Lines and the Principles of Incident Handling
Our 220 kV substation is located far from the urban center in a remote area, surrounded primarily by industrial zones such as Lanshan, Hebin, and Tasha Industrial Parks. Major high-load consumers in these zones—including silicon carbide, ferroalloy, and calcium carbide plants—account for approximately 83.87% of our bureau’s total load. The substation operates at voltage levels of 220 kV, 110 kV, and 35 kV.The 35 kV low-voltage side mainly supplies feeders to ferroalloy and silicon carbide plants
Felix Spark
10/21/2025
Overhead Power Lines & Towers: Types, Design & Safety
Overhead Power Lines & Towers: Types, Design & Safety
Besides ultra-high voltage AC substations, what we encounter more frequently are power transmission and distribution lines. Tall towers carry conductors that leap across mountains and seas, stretching into the distance before reaching cities and villages. This is also an interesting topic—today, let's explore transmission lines and their supporting towers.Power Transmission and DistributionFirst, let’s understand how electricity is delivered. The electric power industry primarily consists of fou
Encyclopedia
10/21/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.