• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Making condition under short circuit current for switchgear
Detailed Explanation of the Making Current Flow and Pre-Strike Phenomenon in SwitchgearIn switchgear, particularly in circuit breakers (CB) and load break switches (LBS), the making current flow refers to the process by which an electric arc is initiated when the contacts begin to close. This process does not start exactly when the contacts physically touch but can occur several milliseconds earlier due to a phenomenon known as pre-strike. Below is a detailed explanation of this phenomenon and i
01/08/2025
Consult
Tip
Consult
Tip
Making condition under short circuit current for switchgear
Detailed Explanation of the Making Current Flow and Pre-Strike Phenomenon in SwitchgearIn switchgear, particularly in circuit breakers (CB) and load break switches (LBS), the making current flow refers to the process by which an electric arc is initiated when the contacts begin to close. This process does not start exactly when the contacts physically touch but can occur several milliseconds earlier due to a phenomenon known as pre-strike. Below is a detailed explanation of this phenomenon and i
12/30/2024
Consult
Tip
Consult
Tip
Puffer interruption in gas HV CB
Detailed Explanation of the Arc Quenching Process in a Puffer-Type SF6 Circuit BreakerIn a puffer-type SF6 circuit breaker, the arc quenching process is a critical mechanism that ensures the reliable interruption of high currents, especially during short-circuit conditions. The process involves the interaction between the main contacts, arcing contacts, and a PTFE (Polytetrafluoroethylene) nozzle, which guides the flow of compressed SF6 gas to extinguish the arc. Below is a detailed explanation
12/28/2024
Consult
Tip
Consult
Tip
Hybrid (vacuum-gas) high voltage circuit breaker prototype
Summary of Hybrid Circuit Breaker BenefitsHybrid circuit breakers (CBs) represent a significant advancement in high-voltage switching technology, combining the advantages of both vacuum and SF6 (now CO2) interrupters. The hybrid design leverages the unique properties of each interrupter to achieve superior performance and environmental benefits. Below is a summary of the key benefits:1.Enhanced Interruption Performance Synergistic Arc Interaction: The hybrid CB design allows for a synergistic in
12/27/2024
Consult
Tip
Consult
Tip
Switching overvoltage mitigation methods in EHV
Fast Insertion of Shunt ReactorsPurpose:Shunt reactors are primarily used to compensate for the capacitance of long transmission lines, which can lead to overvoltages and reactive power issues. They provide a secondary benefit by reducing switching overvoltages when connected, but this is not typically the primary reason utilities install them. The main objectives of shunt reactors include: Capacitance Compensation: Long transmission lines have significant capacitance, especially at Extra High V
12/26/2024
Consult
Tip
Consult
Tip
Dielectric combined voltage tests (BIAS test) on circuit breakers
Dielectric Bias Testing of High-Voltage Circuit BreakersDielectric bias testing is a critical procedure used to evaluate the insulation performance of high-voltage circuit breakers (CBs) under conditions that simulate real-world voltage stresses. In this test, the circuit breaker is subjected to two separate voltages simultaneously: a power frequency (PF) voltage and either a switching (SW) impulse or a lightning impulse (LI). This combination of voltages mimics the actual voltage conditions tha
12/25/2024
Consult
Tip
Consult
Tip
High Voltage Circuit Breaker
Arc Voltage in Gas Circuit BreakersIn gas circuit breakers, the arc voltage is a critical parameter that influences the interruption process and the overall performance of the breaker. The arc voltage can range from a few hundred volts to several kilovolts, depending on various factors. Below is a detailed explanation of the key factors that affect the arc voltage:1.Arc Length Principle: The voltage drop across the arc is directly proportional to the length of the arc. As the arc length increase
12/24/2024
Consult
Tip
Consult
Tip
High voltage switchgear insulators creepage distance extending ways in substations
Site Condition Severity Assessment and Insulator/Bushing Upgrade StrategyStep-by-Step Approach: Measure or Estimate Site Condition Severity: Environmental Factors: Assess the severity of environmental conditions such as pollution, humidity, temperature fluctuations, and salt spray (for coastal areas). Operational Data: Collect data on historical insulator performance, including flashover incidents, arcing, and contamination levels. Field Inspections: Conduct visual inspections to identify si
12/23/2024
Consult
Tip
Consult
Tip
Transient Electromagnetic Emissions(TEE) measurement methods in switchgears
TEE Detection Methods During CB Switching OperationsDuring circuit breaker (CB) switching operations, transient earth voltages (TEEs) are generated by electric discharges within each interrupter. These TEEs, caused by disruptive discharges such as pre-strikes, re-ignitions, and restrikes, exhibit high amplitude and a broadband frequency range. To detect and analyze these TEEs, three primary methods have been developed: TEE Detection with UHF Antennas Description: This method employs four passive
12/21/2024
Consult
Tip
Consult
Tip
Vibration signal application in switchgear
Vibration Signal Analysis for Circuit Breaker (CB) Health MonitoringIntroductionDuring the opening and closing processes of a circuit breaker (CB), a vibration signal is generated. This signal contains valuable information about the health status of the equipment, including the moment of arc contact opening, which can indicate wear and tear, mechanical issues, or other potential problems. One critical aspect of CB health monitoring is the measurement of switchgear contacts ablation, which refers
12/21/2024
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.