Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Circuit breakers basic control circuit functions diagram
Circuit Breakers Control Circuit Functions Diagram Description Circuit Breaker Main Contacts: These are not part of the control circuit. They serve as the primary conducting elements that open and close to interrupt or establish the main electrical circuit. Mechanical Operating Mechanism: This mechanism releases the energy required to move the main contacts between the open and closed positions. It is also excluded from the control circuit proper. Its role is crucial in physically actuating the
05/07/2025
Consult
Tip
Consult
Tip
What is Electronic Relay?
Definition and Basics of Electronic RelaysDefinition: An electronic relay is an electronic switch that operates to open or close circuit contacts using electronic components, eliminating the need for any mechanical movement. In electrical systems, the current carrier pilot relaying scheme is commonly employed in these relays for the protection of transmission lines. This approach enables efficient and precise detection of faults, ensuring the safety and reliability of the power grid.Electronic r
05/05/2025
Consult
Tip
Consult
Tip
Typical mechanical interlocks role for draw out circuit breakers in LV switchgears according to IEEE standard
Safety Features and Requirements for Circuit Breakers Interlocking to Prevent Unauthorized Movement: To ensure operational safety, it is imperative to prevent the movement of a circuit breaker to or from the connected position when the circuit breaker itself is in the closed state. This safeguard helps avoid potential electrical hazards and damage to the equipment. Pre - closing Conditions: Additionally, measures are in place to prevent the closing of the circuit breaker unless the primary disco
04/30/2025
Consult
Tip
Consult
Tip
Percentage Differential Relay
Definition: A percentage differential relay is defined as a type of relay that functions based on the phase difference of two or more similar electrical quantities. It represents an advanced form of differential protection relay. The sole distinction between it and other differential relays lies in the presence of a restraining coil. The percentage differential relay incorporates a restraining coil precisely to address issues stemming from discrepancies in the current ratio when dealing with hig
04/29/2025
Consult
Tip
Consult
Tip
Temperature-Rise test of Large Capacity Generator Circuit Breaker
The temperature rise test is a crucial test for generator circuit breakers to verify their current - carrying capacity. In this test, the maximum test current can reach as high as 35 kA to simulate the real operating environment. The test sample is a complete three - phase installation, but the test is only conducted on a single phase. The air temperature can be adjusted using cooling water.The implementation of this test mainly focuses on the following three aspects, and the layout of the exper
04/29/2025
Consult
Tip
Consult
Tip
Generator circuit breakers(GCB) role in gas turbine power plants
When starting a gas - turbine generator, its rotor must first be accelerated by external means to approximately 60% of the rated speed. Only then does the start - up process become self - sustaining, meaning the turbine can generate enough power to continue the process independently. To achieve this initial acceleration, energy can be supplied by various means, with a static frequency converter (SFC) being a common choice.Generator circuit breakers (GCBs) play a crucial role in this process. The
04/26/2025
Consult
Tip
Consult
Tip
Testing of Circuit Breaker
Circuit Breaker Testing: Challenges and ProceduresTesting circuit breakers is a far more intricate task compared to testing other electrical equipment such as transformers or machines, primarily due to the extremely large magnitudes of short - circuit currents involved. In contrast, the testing of transformers is typically categorized into two main groups: type tests and routine tests.Type Tests of Circuit BreakersType tests are essential for validating the capabilities and confirming the rated
04/25/2025
Consult
Tip
Consult
Tip
Air Blast Circuit Breaker
Air Blast Circuit Breakers: Operation, Advantages, and TypesAn air blast circuit breaker utilizes compressed air or gas as the arc - interrupting medium. Compressed air is stored in a tank and, when needed, released through a nozzle to generate a high - velocity jet. This jet plays a crucial role in extinguishing the arc that forms when the circuit breaker interrupts the electrical current.Air blast circuit breakers are commonly employed for indoor applications in the medium - high voltage range
04/25/2025
Consult
Tip
Consult
Tip
Source short circuit current definition and curves in generator circuit breakers according to IEEE & IEC standard
Rated System - Source Short - Circuit Breaking CurrentThe rated system - source short - circuit breaking current refers to the maximum system - source short - circuit current that occurs at the moment of contact separation. A generator circuit - breaker is required to be able to interrupt this current under the conditions specified in relevant standards. This particular current is observed in a circuit where the power - frequency recovery voltage aligns with the rated voltage of the generator ci
04/25/2025
Consult
Tip
Consult
Tip
Verification of time quantities in commissioning test for Generator circuit breaker (GCB) according to IEC/IEEE
Commissioning Tests for Generator Circuit BreakersOnce a Generator circuit breaker has been installed, comprehensive commissioning tests must be conducted. The primary objectives of these tests are to: Ensure that no damage has occurred during transportation and storage. Verify the compatibility of individual components. Confirm that the assembly has been carried out correctly. Validate the proper performance of the fully assembled generator circuit breaker.Verification of Generator Circuit Brea
04/24/2025