Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
What are the criteria for choosing an electrical circuit breaker?
Criteria for Selecting Electrical Circuit BreakersChoosing the right electrical circuit breaker is crucial for ensuring the safe and reliable operation of power systems. When selecting a circuit breaker, multiple factors must be considered to ensure its performance meets the specific application requirements. Below are the main criteria for selecting an electrical circuit breaker:1. Rated Voltage Definition: The rated voltage of a circuit breaker is the maximum voltage at which it can safely ope
01/08/2025
Consult
Tip
Consult
Tip
Typical difference between SF6 and vacuum switchgear in high voltage
Comparison of Vacuum and SF6 Interrupters in High-Voltage SwitchgearWhen it comes to interrupting fault currents, especially those associated with a very steep rate of rise of transient recovery voltage (TRV), vacuum interrupters have a significant advantage over SF6 (sulfur hexafluoride) interrupters due to their superior dielectric recovery characteristics. Here’s a detailed comparison, including key differences in breakdown statistics, late breakdown behavior, and performance in spe
01/08/2025
Consult
Tip
Consult
Tip
Making condition under short circuit current for switchgear
Detailed Explanation of the Making Current Flow and Pre-Strike Phenomenon in SwitchgearIn switchgear, particularly in circuit breakers (CB) and load break switches (LBS), the making current flow refers to the process by which an electric arc is initiated when the contacts begin to close. This process does not start exactly when the contacts physically touch but can occur several milliseconds earlier due to a phenomenon known as pre-strike. Below is a detailed explanation of this phenomenon and i
01/08/2025
Consult
Tip
Consult
Tip
Making condition under short circuit current for switchgear
Detailed Explanation of the Making Current Flow and Pre-Strike Phenomenon in SwitchgearIn switchgear, particularly in circuit breakers (CB) and load break switches (LBS), the making current flow refers to the process by which an electric arc is initiated when the contacts begin to close. This process does not start exactly when the contacts physically touch but can occur several milliseconds earlier due to a phenomenon known as pre-strike. Below is a detailed explanation of this phenomenon and i
12/30/2024
Consult
Tip
Consult
Tip
Puffer interruption in gas HV CB
Detailed Explanation of the Arc Quenching Process in a Puffer-Type SF6 Circuit BreakerIn a puffer-type SF6 circuit breaker, the arc quenching process is a critical mechanism that ensures the reliable interruption of high currents, especially during short-circuit conditions. The process involves the interaction between the main contacts, arcing contacts, and a PTFE (Polytetrafluoroethylene) nozzle, which guides the flow of compressed SF6 gas to extinguish the arc. Below is a detailed explanation
12/28/2024
Consult
Tip
Consult
Tip
Hybrid (vacuum-gas) high voltage circuit breaker prototype
Summary of Hybrid Circuit Breaker BenefitsHybrid circuit breakers (CBs) represent a significant advancement in high-voltage switching technology, combining the advantages of both vacuum and SF6 (now CO2) interrupters. The hybrid design leverages the unique properties of each interrupter to achieve superior performance and environmental benefits. Below is a summary of the key benefits:1.Enhanced Interruption Performance Synergistic Arc Interaction: The hybrid CB design allows for a synergistic in
12/27/2024
Consult
Tip
Consult
Tip
Switching overvoltage mitigation methods in EHV
Fast Insertion of Shunt ReactorsPurpose:Shunt reactors are primarily used to compensate for the capacitance of long transmission lines, which can lead to overvoltages and reactive power issues. They provide a secondary benefit by reducing switching overvoltages when connected, but this is not typically the primary reason utilities install them. The main objectives of shunt reactors include: Capacitance Compensation: Long transmission lines have significant capacitance, especially at Extra High V
12/26/2024
Consult
Tip
Consult
Tip
Dielectric combined voltage tests (BIAS test) on circuit breakers
Dielectric Bias Testing of High-Voltage Circuit BreakersDielectric bias testing is a critical procedure used to evaluate the insulation performance of high-voltage circuit breakers (CBs) under conditions that simulate real-world voltage stresses. In this test, the circuit breaker is subjected to two separate voltages simultaneously: a power frequency (PF) voltage and either a switching (SW) impulse or a lightning impulse (LI). This combination of voltages mimics the actual voltage conditions tha
12/25/2024
Consult
Tip
Consult
Tip
High Voltage Circuit Breaker
Arc Voltage in Gas Circuit BreakersIn gas circuit breakers, the arc voltage is a critical parameter that influences the interruption process and the overall performance of the breaker. The arc voltage can range from a few hundred volts to several kilovolts, depending on various factors. Below is a detailed explanation of the key factors that affect the arc voltage:1.Arc Length Principle: The voltage drop across the arc is directly proportional to the length of the arc. As the arc length increase
12/24/2024
Consult
Tip
Consult
Tip
High voltage switchgear insulators creepage distance extending ways in substations
Site Condition Severity Assessment and Insulator/Bushing Upgrade StrategyStep-by-Step Approach: Measure or Estimate Site Condition Severity: Environmental Factors: Assess the severity of environmental conditions such as pollution, humidity, temperature fluctuations, and salt spray (for coastal areas). Operational Data: Collect data on historical insulator performance, including flashover incidents, arcing, and contamination levels. Field Inspections: Conduct visual inspections to identify si