Hiiro hii huhesabu kiasi kikubwa cha nishati ambacho kabiki inaweza kukubali kutokana na tofauti ya umeme, kulingana na viwango vya IEC 60364-4-43 na IEC 60364-5-54. Hii hutahidi kuwa mifumo ya msingi (kama vile circuit breakers au fuses) hutofautisha magari mikose majukumu kabla ya kamba kuchoka na kuharibu insulation.
Aina ya Kabiki: Kabiki wa fasi, kabiki wa msingi moja wa uwekezaji wa uhakika (PE), au kabiki wa msingi mingi wa uwekezaji wa uhakika (PE)
Ukubwa wa Mwendo (mm²): eneo la kitako cha kabiki, kinachohusisha ubora wa joto
Mtambao wa Kabiki: Copper (Cu) au Aluminum (Al), inayohusisha resistivity na kupata joto
Aina ya Insulation:
Thermoplastic (PVC)
Thermosetting (XLPE au EPR)
Mineral thermoplastic (PVC) covered
Mineral bare sheath au bare conductor (not exposed to touch, restricted area)
Mineral bare sheath au bare conductor (exposed to touch, normal conditions)
Mineral bare sheath au bare conductor (fire risk environment)
Mineral with metallic sheath used as protective conductor
Nishati inayoruhusiwa (kA²s) — thamani kikubwa inayoruhusiwa ya I²t
Kipengele cha viwango vya chanzo: IEC 60364-4-43 na IEC 60364-5-54
Tatifa ya utaalamu: ikiwa ni I²t iliyohesabiwa ni ndogo kuliko sifa ya I²t ya mifumo ya msingi
Imejenga kwa ajili ya watumiaji wa IEE-Business na wateknolojia wa umeme kuthibitisha ustawi wa joto wa kabiki wakati wa matofauti na kuhakikisha usalama wakati wa matatizo.