Hoc instrumentum calculat maximam admissibilem transmissam energiam (I²t) quam conductor sub condicionibus circuitus aperti sustinere potest, secundum normas IEC 60364-4-43 et IEC 60364-5-54. Illud certificat ut dispositiva protectiva (sicut disjunctores vel fusibilia) interrumpant currentes defectus antequam conductor supercalefietur et insulatio laedatur.

Parametri Input

  • Typus Conductoris: Conductor phase, unico-nucleatus conductor protector (PE), vel multi-nucleatus cable's conductor protector (PE)

  • Dimensio Filii (mm²): Area sectionalis conductoris, quae capacitas thermica afficit

  • Materia Conductoris: Cuprum (Cu) aut Aluminium (Al), quae resistivitatem et generationem caloris influunt

  • Typus Insulationis:

    • Thermoplastica (PVC)

    • Thermosolida (XLPE aut EPR)

    • Thermoplastica mineralia (PVC) operta

    • Vestimentum nuda mineralia aut conductor nudus (non expeditus tactui, area restricta)

    • Vestimentum nuda mineralia aut conductor nudus (expeditus tactui, conditiones normales)

    • Vestimentum nuda mineralia aut conductor nudus (ambitus incendii)

    • Mineralia cum vestimento metallico ut conductor protector usus

Resultata Output

  • Energia transmissa admissibilis (kA²s) — valor I²t maxime tolerabilis

  • Claves normarum referentium: IEC 60364-4-43 et IEC 60364-5-54

  • Examen conformitatis: an computatum I²t minor sit quam caracteristica I²t dispositivi protectivi

Designatum pro electricis designatoribus et installatoribus ut verificent stabilitatem thermicam circuiti aperti cabuli et securitatem operationis in casu defectus.

Donum da et auctorem hortare
Suggestus
Maximum wire length
Calculatio longitatis maximae cabuli
Hoc instrumentum calculat longitudinem maximam cabli, quae adhiberi potest sine excessu permissi declivis tensionis et sine degradando insulamento, iuxta standardes IEC et NEC. Id supportat systemata DC, uniphasica, biphasica, et triphasica, includens conductores parallelos et varias gradationes temperaturarum. Parametri Input Typus Currentis: Directus Currentis (DC), Uniphasicus AC, Biphasicus, vel Triphasicus (3-filis/4-filis) Tensio (V): Inserito tensionem phase-to-neutral pro systemate uniphasico, vel phase-to-phase pro systemate polyphasico Potencia Onus (kW vel VA): Potentia nominata aequipmenti connecti Factor Potentiae (cos φ): Ratio potentiae activae ad apparentem, inter 0 et 1 (default: 0.8) Size Filii (mm²): Area sectionalis conductoris Conductores Phasales Paralleli: Conductores eadem size, longitudo, et materia possunt adhiberi in parallelum; summa permittendi currentis est summa ratingorum individualium core Declivis Tensionis (% vel V): Maximus declivis tensionis permittendus (exempli gratia, 3% pro luminibus, 5% pro motoribus) Materia Conductoris: Cuprum (Cu) vel Aluminium (Al), affectans resistivitatem Typus Cabli: Unipolaris: 1 conductor Bipolaris: 2 conductores Tripolaris: 3 conductores Quadrupolaris: 4 conductores Pentapolaris: 5 conductores Multipolaris: 2 vel plures conductores Temperatura Operationis (°C): Iuxta typum insulamenti: IEC/CEI: 70°C (PVC), 90°C (XLPE/EPR), 105°C (Insulamentum Mineralis) NEC: 60°C (TW, UF), 75°C (RHW, THHN, etc.), 90°C (TBS, XHHW, etc.) Resultata Output Maxima permittenda longitudo cabli (metra) Declivis tensionis actualis (% et V) Resistentia conductoris (Ω/km) Totalis resistentia circuiti (Ω) Standardes Referentiales: IEC 60364, NEC Article 215 Designatum pro ingenieris electricis et installatoribus ad planificandum layoutes cabling et assecurandum acceptabiles niveles tensionis ad termino onus.
Power losses in cables
Dissipatio potentiae per cables
Hoc instrumentum calculat perdas potentiae (perdas I²R) in cabulis propter resistentiam conductoris durante fluxu currentis, secundum normas IEC et NEC. Id supportat systemata DC, uniphasica, biphasica et triphasica, includens conductores parallelos et varios types insularum. Parametri Input Type Currentis: Directus Currentis (DC), Uniphasis AC, Biphasis, aut Triphasius (3-filis/4-filis) Voltage (V): Inseri voltage phase-to-neutral pro uniphasico, aut phase-to-phase pro polyphasico Potestas Onus (kW vel VA): Potestas nominata apparatus connecti Factor Potentiae (cos φ): Ratio potestatis activae ad apparentem, inter 0 et 1 (default: 0.8) Size Filo (mm²): Area sectionis transversalis conductoris Materia Conductoris: Cuprum (Cu) aut Aluminium (Al), quod afficit resistivitatem Conductores Phase Paralleli: Conductores eadem size, longitudo, et materia possunt uti in parallelum; summa currentis permittibilis est summa ratingorum core individualium Longitudo (metra): Distinctio unidirectionalis ab supply ad onus Temperatura Operativa (°C): Pro type insulari: IEC/CEI: 70°C (PVC), 90°C (XLPE/EPR), 105°C (Insulatio Mineralis) NEC: 60°C (TW, UF), 75°C (RHW, THHN, etc.), 90°C (TBS, XHHW, etc.) Resultata Output Resistentia Conductoris (Ω/km) Summa Resistentia Circuitus (Ω) Perda Potentiae (W vel kW) Perda Energetica (kWh/anno, optional) Cadens Voltage (% et V) Correctio Temperaturae pro Resistentia Normae Referentiales: IEC 60364, NEC Article 310 Designatum pro ingeniosis electricis et installatoribus ut evaluant efficaciam circuitus, consumptio energetica, et performance thermica.
Wire size
Calculatio areae sectionis fili
Hoc instrumentum calculat aream sectionalem conductoris recommendatam basata in standardo IEC 60364-5-52, utens parametris sicut potencia onus, voltage, et longitudo circuiti. Parametri Input Tipo Currentis: DC, AC uniphasalis, biphasalis, vel triphasalis (tria filia vel quattuor filia) Voltage (V): Inter phasem et neutrum (uniphasalis) vel inter duas phases (multiphasalis) Potencia Onus (kW vel VA): Potentia nominata apparatus Factor Potentiae (cos φ): Intervallo 0–1, valor default 0.8 Longitudo Lineae (metri): Distantia unidirecta ab origine ad onus Maxima Voltage Decrescens Permissibilis (% vel V): Saepe 3% Temperatura Ambientalis (°C): Affectat capacitate portantis currentis conductoris Materia Conductoris: Cuprum (Cu) vel Alluminium (Al) Tipo Insulationis: PVC (70°C) vel XLPE/EPR (90°C) Modus Installationis: sicut superficiale, in ductu, sepultum (secundum Tabulam A.52.3 IEC) Numerus Circuitorum in Eodem Ductu: Utitur ad applicandum factor de-rating gruppi An omnes cables paralleli installati in uno ductu? Permitte tamanos conductorum minus quam 1.5 mm²? Resultati Output Aread sectionalis conductoris recommendata (mm²) Numerus parallelorum conductorum necessarius (si aliquid) Capacitas actualis portantis currentis (A) Decrescens calculata voltage (% et V) Conformitas cum requirementibus standardis IEC Tabulae standard referentiales (sicut B.52.2, B.52.17) Hoc instrumentum est designatum pro ingenieris electricis, installatoribus, et studentibus ut facili et conformiter dimensionent cables.
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum