Kpụrụ ụdị Nkà ọnụ na Nsọpụrụ Ezi nke Otu ụzọ Mmiri ma ọ bụ Okwu Ikpe Site na Mgbakwụnye Akụkụ Mmiri Gas (HV GIS) (Nkà ọnụ site na Thailand)

1. Background ta na Project
Climate na Thailand na tropical ya jin daɗi abincin da ke kusa da infrastructural power. Don samun ingancin grid, ​High Voltage Gas Insulated Switchgear (HV GIS)​ ya zama muhimmanci a matsayin tushen da ake zaɓe saboda kyakkyawan shi a tsakanin adadin al'amuran. Ba da kisa mai yawa da fatacciyar mafi yawa da 80%, ​HV GIS solutions​ za su iya lura cewa an yi design mai karfi, durability na abubuwa, da kuma monitoring mai sauƙi.

2. Solutions

2.1 Optimization na Material da Structure don High Voltage Gas Insulated Switchgear (HV GIS)

  • Materials Mai Yawanci:

​High Voltage Gas Insulated Switchgear (HV GIS) ​na enclosures sun amfani da 316L stainless steel da C5-M coatings, wanda suka ci gaba da test na 2,000-hour salt spray (ISO 9227).

Galvanized supports (IP65) suke soke kisa mai yawa, wanda ita ce muhimmanci don ​HV GIS​da take da zaman lafiya a cikin zones na coast na Thailand.

  • Design Mai Karfi:

​HV GIS​hybrid insulation (SF6/N2) ya rage surfaces mai yawa da 60%, wanda ya ƙare sakamako na risks na condensation.

Fluororubber seals (-40°C–150°C) sun tabbatar da ​High Voltage Gas Insulated Switchgear​stability a lokacin da tafiyar temperature ta faru.

2.2 Adaptation na Environment don High Voltage Gas Insulated Switchgear (HV GIS)

  • Systems Mai Yawanci Na Condensation:

​HV GIS​ya amfani da humidity sensors da MIL-STD-810G filters, wanda suke rage 99% na particles mai yawa a ventilation ports.

Active dehumidification ya faru a >70% humidity, wanda ita ce abin da ya bukata don ​High Voltage Gas Insulated Switchgear ​a climates na tropical.

  • Treatments Na Surface:

​HV GIS ​components sun yi Sa2.5 sandblasting da 3-layer coatings, wanda suke rage resistance na salt spray zuwa 3,000 hours (ASTM B117).

​2.3 Smart Monitoring don High Voltage Gas Insulated Switchgear (HV GIS)

  • Analytics Ta Hanyar Real-Time:

Cloud-based tracking of ​HV GIS​ parameters (SF6 density, partial discharge) ya ci gaba da 95% fault prediction accuracy.

AI models sun nuna trends na corrosion, wanda ya ba da damar maintenance mai fiye na ​HV GIS​ 6 months in advance.

  • Protocols Na Maintenance:

Biannual coating checks suke tabbatar da ​High Voltage Gas Insulated Switchgear​adhesion ≥95% a sites na coast.

On-site Q-Lab Q-FOG chambers sun bayyana spare parts, wanda suke amincewa da requirements na lifecycle na ​HV GIS​.

3. Results

​3.1 Reliability Mai Zama:

  • ​High Voltage Gas Insulated Switchgear (HV GIS) ​MTBF ya zama daga 5 zuwa 15 years, da 85% fewer salt spray failures.
  • Substations na Bangkok sun rasa 0 condensation events (GIS internal humidity <50%).

​3.2 Benefits Na Economy:

  • 40% lower ​HV GIS​maintenance costs via reduced coating replacements and outage losses.

3.3 Integration Na Renewable:

  • ​HV GIS​ compact design ya ba da 50% space savings for Thailand’s 1.2GW Andaman Sea wind farm transmission.
05/27/2025
Tambayar Da Yawanci
Procurement
Analisis na Labarai da Dalilai don Turbin Masu Faduwar Zane Don Turbin Mai Sani a Jami'a
1. Zuruwa na Tarihin Karkashin Da Farkon Iya​1.1 Daban-daban na Zuruwa Wanda Ke Farkon Iya​Transforma da zama a tsaye da kuma transforma da zama a uku ke da daban-daban da suka faruwar da zuruwa. Transforma da zama a tsaye suna amfani da zuruwa na E ko ​zuruwa mai kasa, hakan da transforma da zama a uku suna amfani da zurwa na uku ko gurbin zuwa. Wannan farkon zuwa yana taka muhimmanci ga iya:Zuruwa mai kasa a cikin transforma da zama a tsaye ke hada hanyar tattalin mafi girma, ​na kusan kamar h
Procurement
Integirin Sọlusi na Transformers ọnụ nke Nsogbu site na Ụdị Ekwupụta Na-akwado: Ihe Mmemme Nke Teknụziri na Ụzọ Ọhụrụ dị ka Anya bụ Ịtụle Anya
1. Background and Challenges​Distributed integration of renewable energy sources (photovoltaics (PV), wind power, energy storage) imposes new demands on distribution transformers:​Volatility Handling:​​Renewable energy output is weather-dependent, requiring transformers to possess high overload capacity and dynamic regulation capabilities.​Harmonic Suppression:​​Power electronic devices (inverters, charging piles) introduce harmonics, leading to increased losses and equipment aging.​Multi-Scenar
Procurement
Akwụkwọ Nsogbu Nke Isiokwu Ugbu A Site Asia: Egwuregwu, Ọdịnala & Nkasi Isiokwu
1. Daidokunin da na Nauyin Kirkiro na Taurari a Masarautar Asia​1.1 ​Daidokunin Daɗiyan Tsarin Kirkiro​Kirkiro mai yawa a cikin masarautar Asia: Ana amfani da 220V/230V tsohon-kirkiro kan, amma a wurareen al'adu ana buƙata 380V uku-kirkiro, kuma akwai tsarin kirkiro da ba su dace-ba kamar 415V a wuraren.Yawan kirkiro (HV): Yawancin da ke 6.6kV / 11kV / 22kV (wasu ƙasashin kamar Indonesia sun amfani da 20kV).Tsarin kirkiro ta hanyar (LV): Daidai 230V ko 240V (tsohon-kirkiro biyu-ko biyar).1.2 ​Na
Procurement
Aiki na ƙarin Transformer: Kyakkyawan Yawan Aiki da Takaice a Cikin Ƙarfin Transformer Da Dadi
1. Integrated Design & Protection Features of American-Style Pad-Mounted Transformers1.1 Integrated Design ArchitectureAmerika-styled pad-mounted transformers na yi kaɗauƙi a cikin kasa daban-daban da suka samu muhimmanci - core, windings, high-voltage load switch, fuses, arresters - a cikin kasa daya, tare da transformer oil ya zama insulation da coolant. Bashar ta shi sun hada da biyu:​Babban Section:​​High & Low Voltage Operation Compartment (da elbow plug-in connectors mai yin live-f
Aika tambaya
Kwamfuta
Samun IEE Business Application
Yi amfani da IEE-Business app don samun abubuwan aikin, samun halayyin, haɗi da malamai, kuma kai tsauraran takaiddun kasoshin duka lokaci, duka wurin—dole bai karfin takamaltar hulɗin ku na alintakargida da kasuwanci.