I. Kahimtug sa Proyekto ug mga Kritikal nga Isyu aron Tugoson
Isip usa ka gihigugmaang gamiton nga low-voltage electrical device, ang AC contactors naglupad og key role sa long-term operation systems. Apan, ang ilang tradisyonal nga disenyo adunay fundamental nga sulirun: ang contacts mahimong mogenerate og arc kung mubo ang circuit.
Kini nga inherent nga sulirun molihok og serye sa serius nga problema:
II. Core Solution: Arc-Free Breaking Principle
Ang core innovation sa solution niini nahimutang sa pag-adopt sa hybrid structure nga naglakip og main contacts + parallel thyristor module, plus precise triggering control circuitry aron eksaktong synchronized ang ilang switching sequences.
Operating Phase |
Time Node |
Action Process |
Core Objective and Effect |
Connection |
|||
10ms after coil energization |
Trigger circuit sends signal; three pairs of bidirectional thyristors instantly conduct. |
Make-first: Current path established first, preparing for contact closure → arc-free connection. |
|
15ms after coil energization |
Contactor main contacts close, short-circuiting the thyristors. |
Switchover: Mechanical contacts carry main circuit current; thyristors turn off automatically due to zero voltage difference → energy-efficient. |
|
Disconnection |
|||
After coil de-energization |
Contact pressure decreases; contact resistance increases; voltage drop across contacts rises to ~0.10V. |
Preparation: Voltage drop signal triggers control circuit → thyristors conduct immediately. |
|
12ms after coil de-energization |
Main contacts begin to open. |
Arc-free breaking: Current fully transferred to thyristor path → contacts break at zero current → completely arc-free. |
|
18ms after coil de-energization |
Trigger circuit stops signal; thyristors turn off naturally at current zero-crossing. |
Break-last: Completes arc-free breaking of the entire circuit. |
III. Process Implementation and Modification Plan
Kini nga solution nagsunod sa principle sa "targeted modification based on mature products," significantly reducing industrialization barriers and costs.
Specific Modifications:
IV. Test Conclusions and Significant Value
The AC contactor developed based on this solution has passed rigorous mechanical and electrical endurance tests, verifying its safety, reliability, and feasibility.
Core Value Delivered:
• Revolutionary Performance Improvement: Complete elimination of switching arcs increases electrical endurance by tens of times, theoretically reaching the level of mechanical lifespan. Also reduces contact maintenance and increases allowable operating frequency.
• Expanded Application Fields: The arc-free characteristic enables safe application in high-risk environments with strict explosion-proof and fire-proof requirements, such as petrochemical plants, coal mines, aerospace, etc., making it a highly reliable core component in control systems and power distribution systems.
• Eco-Friendly: Significantly reduces arc-induced grid pollution and electromagnetic interference, aligning with the development trend of modern green electrical appliances.