China Three-phase Automatic Step Voltage Regulator Wholesale Supplier-11kV to 33kV

Add us on Google
  • China Three-phase Automatic Step Voltage Regulator Wholesale Supplier-11kV to 33kV

Key attributes

Brand ROCKWILL
Series RVR-3
Rated voltage 11kV to 33kV
Rated capacity 315–25000kVA
Rated frequency 50 / 60Hz
Description

RVR series line automatic voltage regulators are the patent products of Rockwill which are used to improve the power quality.After years of large-scale grid construction in rural areas, 11kV or 33kV and rural low voltage power network has been improved a lot.

Most of the high loss distribution transformers turns to low loss ones, which improving the power supply quality. But the financial source is limited, especially the problem of super power supply radius in some remote areas, which cannot be solved by using high voltage distribution network covers. A certain number of power supply radius are longer than the long-distance line the country sets.

The end voltage cannot be guaranteed, the power factor cannot meet the requirements and the line burdens more damages. With the rapid development of economy, higher quality of power is required of rural users.

RVR series line automatic voltage regulators can realize the change to transformers according to the line voltage situation by adjusting automatically the gear of on-load tap changer, thus to guarantee that the output voltage is stable in a certain range. It can be widely used in the power supply line with far power supply distance, heavy power supply load, big voltage fluctuation, and nonstandard power quality. It can also be used in the enterprises where the voltage quality cannot satisfy the production.

Product Showcase Video

Working Principle

RVR‑series line automatic voltage regulators consist of three components: autotransformer, on‑load tap‑changer and automatic controller.

The autotransformer coil includes a series excitation coil, shunt‑wound coil and control coil. The shunt‑wound coil has multiple taps. These taps, together with input and output terminals, form a series connection via different contacts of the on‑load tap‑changer. Tap‑changer operation changes the autotransformer transformation ratio for voltage regulation.

As the common winding, the shunt‑wound coil generates magnetic field for energy transfer. The control coil supplies working power and sampling signals to the controller.

The on‑load tap‑changer enables contact switching under load. Taps of the series winding connect to different contacts of the tap‑changer. Output voltage is adjusted by contact switching and ratio variation. Tap positions are available in 7, 9, 13, 17, 25 steps, selected based on tap‑changer service life and customer voltage‑accuracy requirements.

The automatic controller is the core unit. Equipped with a military‑grade SCM chip, it integrates display, key, voltage‑sampling, current‑sampling, status‑input, communication, control‑output and data‑storage circuits. It features high reliability and strong anti‑interference performance, suitable for harsh outdoor conditions.

It acquires P0‑P1‑P2 voltage signals and C1, C2 current signals, and compares them with preset program values. If the measured value exceeds the upper limit, it commands the tap‑changer to raise tap position; if below the lower limit, it commands the tap‑changer to lower tap position.

Working Principle Diagram

Key Features

  • Uses auto transformers structure, and can realize on-load automatic voltage adjustment within the scale of range: (-10%~+10%), (-5%~+15%), (0~+20%), (0~+30%) or customized.
  • Good control performance and communication function, and realizes the four functions of telemetry, remote signaling, remote regulating, and remote control.
  • Adopts unique anti-interference measure and guarantees the normal work of controller.
  • The controller has high gear and low gear limit protection in case that the tap-changer loses function.
  • On-load tap-changer tank is separated from the ontology tank of autotransformers.
  • Small volume, big capacity, light weight, low loss, and is easy to install.
  • Has obvious loss reducing and energy saving effect.
  • High-cost performance and reliance.

Overall dimensions 

China Three-phase Automatic Step Voltage Regulator Overall dimensions 

Technical Parameters

No.

Parameter

Operation range

1

Rated voltage

6kV、11kV、22 kV、33kV or customized

2

Rated capacity

315kVA~5000kVA : 6KV

500kVA~9000kVA : 11KV

500 kVA~16000kVA : 22KV

500kVA~25000KVA : 33KV

3

Rated frequency

50HZ/60HZ

4

Wiring mode

Three-phase and three-wire type single winding star wiring

5

Number of tapping steps

7, 9 ,13,17 or 25 or customized

6

Cooling method

Oil immersed and natural/self-cooled

7

Range of regulation

Default : -10%~+10%,  -5%~+15%

Optional : 0~+20% ,-20%~+20%

if you have request, please let us know when you place the order

Technical parameter of automatic controller

No.

Parameter

Operation range

1

Operating supply voltage

380V AC, 50HZ

2

Simulation quantity

2‐way 0 ~ 220V voltage input, 1‐way 0 ~5A current input and 1-way platinum resistance oil temperature input.

3

Switch quantity

Max. 20‐way switch quantity input and max. 6-way switch quantity output

4

Measuring precision

Class 0.5

5

Anti‐interference grade

Conform to the requirements of Class IV of IEC61000‐4:1995

Installation drawings

 China Three-phase Automatic Step Voltage Regulator Installation drawings

Field Operation Photo of Three‑phase Automatic Step Voltage Regulator

China Three-phase Automatic Step Voltage Regulator Wholesale Supplier-11kV to 33kV

Applications

  • Medium-voltage distribution line voltage stabilization for utility networks
  • Industrial facilities requiring consistent power quality despite load fluctuations
  • Rural and urban feeder regulation to maintain end-user voltage within statutory limits
  • Integration into substation, pole-mount, or pad-mount distribution systems

Additional voltage ratings and customized configurations are available on request. Contact Rockwill for application-specific sizing and technical support.

Solutions - Voltage Regulator

  • Step Voltage Regulator Solutions for Enhancing Rural Distribution Network Stability and Efficiency
    Ⅰ. Technical Principle and Core Advantages1. Working PrincipleThe 32-step voltage regulator is a tap-switching type voltage regulation device that adjusts voltage by automatically switching the tap positions of series windings:Boost/Buck Mode: A Reversing Switch selects the relative polarity of the series and parallel windings, achieving a ±10% voltage regulation range.32-Step Fine Regulation: Each step adjusts the voltage by 0.625% (32 steps total), preventing abrupt voltage changes and ensurin
  • Innovative Solutions of Step Voltage Regulators in Power Distribution Systems
    1 Executive SummaryVoltage Management Challenges in Modern Distribution Networks: Long-distance feeders causing voltage drop; Distributed energy resource (DER) integration leading to bidirectional power flow; Load fluctuations causing frequent voltage variations.Technical Features of Step Voltage Regulators (SVRs): Employs tap-changing technology to alter transformer winding turns ratio, achieving a ±10% voltage adjustment range (typically in 32 steps, 0.625% per step); Core advantage
  • Zanzibar project – voltage regulator selection misalignment with load requirements: root cause analysis & solution
    I. Incident BackgroundThe 33kV line voltage regulator (13 taps, 4% step per tap) supplied by our company for the Zanzibar project has been commissioned and is currently in operation. However, during nighttime periods of low load, the regulator has repeatedly caused the low-voltage side voltage at the downstream factory to rise to 420V, triggering overvoltage shutdowns of production machinery. Following these incidents, the customer specified a maximum permissible low-voltage side tolerance of 41
  • Midnight Voltage Surge to 420V Causes Plant Shutdown? The RVR-1 Automatic Voltage Regulator Breaks the
    Introduction: A "Low-Load Hours" Crisis That Struck in the Early MorningBetween 1:00 AM and 7:30 AM on August 24, while most plants were in their low-production overnight window, one facility was forced to shut down three times in succession due to voltage spikes reaching 420V. This was not a grid fault, but a classic case of "off-peak voltage over-limit."During late-night hours when grid load is light, line losses are minimal, and excess reactive power causes the terminal voltage to rise sharpl
  • Step Voltage Regulator Solutions for Southeast Asia: Empowering Grids and Enhancing Voltage Stability
    Ⅰ. Southeast Asia Power Sector: Status and Demand Analysis Grid Weakness and Energy Access Challenges Over 35 million people in Southeast Asia still lack electricity access. Remote areas rely on diesel generators (e.g., Padua Village, Indonesia), experiencing unstable supply and high costs. Tropical climate leads to high line losses. Integration of photovoltaic (PV) systems and electric vehicles (EVs) exacerbates three-phase voltage imbalance issues in distribution grids. Demand for New Ener

Case Studies - Voltage Regulator

Related Blogs - Voltage Regulator

Documentation Resource Library Voltage Regulator

33 kV On Load Automatic Voltage Regulator
Restricted
33 kV On Load Automatic Voltage Regulator 33 kV On Load Automatic Voltage Regulator
Technical Data
English
PDF
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure 6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
PDF
Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
RVR-1 Type  Single Phase Automatic Voltage Regulator  6kV-34.5kV
Restricted
RVR-1 Type Single Phase Automatic Voltage Regulator 6kV-34.5kV RVR-1 Type Single Phase Automatic Voltage Regulator 6kV-34.5kV
Operating Instruction
English
PDF
RVR-1  Single Phase Automatic Voltage Regulator 6kV-34.5kV
Restricted
RVR-1 Single Phase Automatic Voltage Regulator 6kV-34.5kV RVR-1 Single Phase Automatic Voltage Regulator 6kV-34.5kV
Catalogue
English
PDF

Certifcations Voltage Regulator

  • RVR1-100A-11 single phase 32-step voltage regulator test
  • RVR1-100A-22 single phase 32-step voltage regulator
  • RVR1-200A-22 single phase 32-step voltage regulator
  • RVR-5000/10 Three Phase Oil Immersed Automatic Voltage Regulator test
  • RVR1-400A-22 single-phase 32-step voltage regulator

Frequently asked questions

It is used to improve power quality by automatically stabilizing the output voltage of long-distance distribution lines, heavy-load feeders, and industrial power supply systems.

The automatic controller samples line voltage and current, then drives the on-load tap-changer to change the autotransformer ratio, keeping the output voltage within a preset range.

According to the product description, it is suitable for rural 11kV and 33kV distribution networks and similar medium-voltage line applications.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register