SG Series Isolation transformer

  • SG Series Isolation transformer
  • SG Series Isolation transformer
  • SG Series Isolation transformer

Key attributes

Brand POWERTECH
Model NO. SG Series Isolation transformer
Rated capacity 35KVA
Primary voltage 10.5kV
Secondary voltage 0.4kV
Series SG Series

Product descriptions from the supplier

Description

Overview

1. The transformer core uses high-quality cold-rolled silicon steel sheets from Baowu Group, cut and stacked using a seven-step 45° fully mitered joint process. No-load losses, no-load current, and operating noise are all superior to national and industry standards, effectively reducing product weight, dimensions, and greatly reducing transformer inrush current during closing.
2. According to different protection classes, ANSYS simulation technology is used for multi-physics field coupling simulation to design corresponding heat dissipation and cooling systems. The structure fully considers air circulation to ensure heat dissipation performance while effectively providing protection.
3. The transformer enclosure is made of 2.0mm cold-rolled steel plate, with high-temperature silicone rubber strips sealing between the frame and movable panels, meeting protection class requirements while effectively reducing vibration noise. The enclosure meets C5M anticorrosion standards, with corrosion resistance, weather resistance, and UV resistance. The coating is crack-resistant and wear-resistant.
4. The transformer is easy to wire and can be equipped with voltmeters, ammeters, power indicators, circuit breakers, etc., according to user requirements. It can also use our company's developed intelligent module to comprehensively monitor the transformer's operating status, including real-time power transmission, operating voltage and current, operating temperature, insulation performance monitoring, etc.
5. The design of double insula tion, reinforced insulation, and auxiliary insulation systems, as well as the selection of insulation materials, are superior to national standards, ensuring the safety of products and equipment, making it a true "isola tion transformer".

 

Environmental Conditions for Used

Altitude:≤ 2000m (products for altitudes above 2000m can be customized)
Ambient temperature: -40℃ ~+55℃
Relative humidity: ≤ 95%
 

Applications:

Isolation transformers are used in situations where high power quality and safety requirements are needed, such as medical equipment, laboratory instruments, industrial automation control systems, and electronic communication equipment. Their main purpose is to electrically isolate the input side from the output side, thus pr eventing interference signals, noise, electric shock, etc. from the power source from damaging equipment and personnel, and providing stable, reliable, and safe power to ensure normal equipment operation and personnel safety.

 

If you need to know about or order switching power supplies of other specifications, Please check the model selection manual.↓↓↓

Or you are welcome to contact us.↓↓↓

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 580000m² Total staff: Highest Annual Export(usD): 120000000
Workplace: 580000m²
Total staff:
Highest Annual Export(usD): 120000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Core Value and Innovative Applications of 12kV Medium Voltage Switchgear in Smart Substations​
    With the Rapid Development of Smart Grids and the Integration of Renewable Energy Medium Voltage (MV) Switchgear, as the core power distribution equipment in substations, directly determines the stability of the power system through its reliability, intelligence, and space efficiency. This article delves into the key technologies, scenario-specific solutions, and practical benefits of Medium Voltage Switchgear in substations.Core Requirements for Substation ScenariosHigh Reliability Requirements
    06/12/2025
  • Withdrawable 12kV Medium Voltage Switchgear: The Indispensable Pivot of Flexibility and Safety in Smart Grids
    At the core of medium-voltage power distribution systems in industrial facilities, commercial complexes, and data centers, switchgear acts as a silent commander, governing the lifeline of electrical flow. Among various solutions, ​Withdrawable Switchgear​has become synonymous with reliability in modern MV systems due to its unique design philosophy. Compared to fixed switchgear, its "withdrawable" feature delivers compelling advantages, setting new benchmarks for ​operational efficiency​and ​per
    06/12/2025
  • Core Dilemma in Southeast Asia 12kV Medium Voltage Switchgear​
    Southeast Asia’s rapidly growing power demand (GDP growth >5% annually) combined with extreme climatic conditions—high temperature, humidity, and salt spray corrosion—necessitates balancing lifecycle costs with climate resilience in switchgear selection. This article analyzes the optimal cost-performance solutions between GIS and AIS.​I. GIS vs. AIS Cost Comparison Model (Southeast Asia Context)​​​1. Initial Investment Costs​2. Long-Term Operational Costs​​GIS Advantages:Ext
    06/12/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.