Premium quality mining distribution transformer

  • Premium quality mining distribution transformer

Key attributes

Brand Vziman
Model NO. Premium quality mining distribution transformer
Rated capacity 1000kVA
Voltage grade 10KV
Series BK11
Description

Product overview:

 Mine distribution transformer:

  • It is used in places where there is coal dust and biogas in mine and there is no explosion danger. It is used for electric driving and lighting.

  • Mine general transformer is strong in structure and low in appearance. The tank is mechanically strong enough to withstand pressures of 0.1 mpa without permanent deformation. The high and low voltage inlet and outlet lines of mine transformers are equipped with cable junction boxes filled with insulating adhesive.

  • Mine general transformer is equipped with no excitation voltage regulation, voltage regulation range is ±5%; The secondary coil leads to 6 terminals, which can use Y - connection or Delta - connection.

Mine flameproof distribution transformer:

  • Used in places with explosive danger in mines. This kind of transformer is mostly made of dry type, the main structural characteristic is that all the joint surface of the box shell is made according to the flame-proof requirements, and it can bear the internal pressure of 0.8 mpa.

  • The capacity of mine dry-type transformer is usually 4000kVA (4MVA) and 2500kVA (2.5MVA), designed for electric drill, lighting, signal and other equipment power supply. Its inlet and outlet lines are led out by cable through the outlet sleeve.

  •  High reliability of operation verification in more than 50 countries and regions around the world.

  • Our products are mainly exported to Iran, Kazakhstan, Uzbekistan, Kazakhstan, Pakistan, Indonesia, Chile and other countries and regions.

Leading technology:

  •  Large capacity, low loss, low noise (< 65dB) more energy saving

  •  Excellent performance index, actual measurement is better than GB and IEC standards

  •  The product has strong over-load capacity and over-voltage capacity, and can run safely for a long time under rated load

  •  Strong impact resistance and short circuit resistance

  •  With microcomputer protection device (measurement, control, protection, communication, etc.)

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 30 years of paint (coating corrosion resistance within 100h, hardness &ge;0.4).

  • Use heat dissipation tubing (double row and three row tubing adopt insert mode) to achieve good heat dissipation effect.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • China produces high quality anaerobic copper.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Ordering instructions

  • Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc.).

  • Other customization requirements.

  • Normal delivery period is 30 days.

  • Worldwide fast delivery.

What safety precautions need to be paid attention to when using mining distribution transformer underground?

Explosion-proof Safety:

Shell Inspection:

  • For flameproof mining distribution transformer, it is necessary to regularly inspect the integrity of the flameproof shell. The flameproof joint surfaces should remain smooth and free from damage, and the flameproof clearance must meet the specified standards. For example, the flameproof clearance is generally required to be within a specified range, such as around 0.1 - 0.2 mm. Any clearance exceeding the standard may lead to the failure of the explosion-proof performance.

  • The bolts and other connecting parts on the shell should be complete and tightened to prevent loosening during the operation due to vibration or other reasons, which may affect the flameproof effect.

Preventing Internal Faults from Causing Explosions:

It is essential to ensure that the quality and installation of the electrical components inside the mining distribution transformer meet the requirements to prevent faults such as short circuits and overloads from generating electric sparks or high temperatures. For example, the insulation of the windings should be in good condition to avoid inter-turn short circuits. Meanwhile, appropriate overload protection and short-circuit protection devices should be installed so that when overload or short-circuit situations occur, the power supply can be cut off in a timely manner to prevent the generation of energy sufficient to cause explosions inside the mining distribution transformer.

Electrical Safety:

Grounding Safety:

  • Mining distribution transformer must have reliable grounding. The grounding resistance should meet the specified requirements, and generally, the grounding resistance is required to be no greater than 2&Omega;. Good grounding can lead the current into the earth when leakage or other faults occur in the mining distribution transformer, thus avoiding electric shocks to personnel.

  • The grounding devices should be regularly inspected to ensure that the grounding connections are firm and that the grounding electrodes are free from corrosion and other damage. For example, if the grounding electrodes are in a damp underground environment for a long time, they are prone to rust and corrosion, which will reduce the grounding performance and need to be replaced in a timely manner.

Preventing Electric Shocks:

  • The high-voltage and low-voltage terminals of the mining distribution transformer should be enclosed or protected to prevent accidental contact by personnel. During maintenance and other operations, the power supply must be cut off first, and a warning sign saying "Someone is working, Do not switch on" should be hung.

  • Underground operators should be equipped with personal protective equipment such as insulating gloves and insulating boots, and they should receive relevant electrical safety training to be familiar with the operation and safety precautions of the mining distribution transformer.

Frequently asked questions

General mining distribution transformers are designed for areas with coal dust but no explosion risk featuring a strong low profile structure with a 0.1 MPa pressure rating. Flameproof models are dry type units built for explosive environments with shells that can withstand 0.8 MPa internal pressure and meet strict flameproof joint standards.

What specific safety standards must the flameproof shell joints maintain?

The integrity of the flameproof shell is critical for underground safety. Flameproof joint surfaces must remain smooth and undamaged with clearances typically maintained between 0.1 and 0.2 mm. All bolts and connecting parts must be tightly secured to prevent any failure of the explosion proof performance during operation.

What are the grounding requirements for ensuring electrical safety underground?

Mining distribution transformers must have a reliable grounding system with a grounding resistance of no more than 2 ohms. This system must be regularly inspected for corrosion or damage caused by the damp underground environment to prevent electric shocks and ensure leakage currents are safely directed to the earth.

How do these transformers achieve high efficiency and energy savings?

The mining distribution transformers use high quality cold rolled grain oriented silicon steel from Baowu Steel Group and high quality anaerobic copper. Combined with precision CNC processing and robotic welding these materials minimize performance loss no load current and noise levels to below 65dB while meeting GB and IEC standards.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register