Outdoor RPS-15kV/1250A SF6 load break switch

  • Outdoor RPS-15kV/1250A SF6 load break switch

Key attributes

Brand ROCKWILL
Model NO. Outdoor RPS-15kV/1250A SF6 load break switch
Rated voltage 15kV
Rated normal current 1250A
Power frequency withstand voltage 50Hz
Mainly active load breaking current 1250A
Series SF6

Product descriptions from the supplier

Description

Description:

  • This is a high standard design SF6 gas load break switch which is suit for pole mounted.

  • RPS type load break switch is KEMA type tested.

  • RPS type load break switch can combined as below different functions switchgear:

  • Manual type load break switch

  • Motorize type load break switch

  • Remote control load break switch

  • Automatic sectionalizer

Features:

  • The high quality 3 mm stainless steel are used for tank.

  • Minimum welding line to minimize corrosion, and specifically to guarantee the safety of the  operation personnel.

  • Even with the internal arc faults at the maximum fault capacity of the tank the RPS can  withstands an internal fault without venting hot gases.

  • The independent spring operation mechanism adopt ROCKWILL® patent spiral spring, provides a guaranteed load  break fault make capability by ensuring the opening and closing speed of the switch.

  • Provided with light reflecting position indicator which are directly connected to the switch operating  shaft providing clear and unambiguous switch position indication.

  • Indicator made of light reflecting material, which  is easily visible from ground level even at night in driving rain.

Parameters:

Outdoor RPS-15kV/1250A SF6  load break switch

Rated voltage

15kV

Power frequency withstand voltage

50Hz

to earth and between phases

28kV

across the isolating distance

32kV

to earth and between phases

75kV

across the isolating distance

85kV

Rated normal current

1250A

Mainly active load breaking current

1250A

Number of breaking operations CO

400times

Line-charging breaking current

50A

Cable-charging breaking curren

50A

Earth fault breaking current

50A

under earth fault conditions

28A

No-load transformer breaking current

\

Short-time withstand current, Ik

20 kA/4 s

Peak withstand current

50kA

Short-circuit making current

50kA

main switch 50 kA (CL E3)

5times

main switch 31.5 kA (CL E3)

10times

earthing switch 50 kA (CL E2)

3times

earthing switch 31.5 kA (CL E3)

5times

Ambient air temperature limits

-40°C...+60°C

main switch

5000times

earthing switch

2000times

Filling pressure (+20°C)

1.4-1.5bar (abs)

density switch

1.2bar (abs)

density gauge

1.2bar (abs)

low gas lock-out mechanism

1.1bar (abs)

Composite bushing

115kg

Porcelain bushing

125kg

Motorize

Add 20kg

Degree of protection of the mechanism box

IP67


Monitoring Functions:

Monitoring Functions

Primary/Secondary Phases and Earth Currents

Direction

Primary/Secondary Line and Phase Voltages

Apparent Power and Power Factor

Real and Reactive Power

Historical Demand Record

Positive Phase Sequence Voltage & Current

Negative Phase Sequence Voltage & Current

Zero Phase Sequence Voltage

Frequency

Binary Input/Output status

Trip circuit healthy/failure

Time and date

Fault records

Event records


External dimensions:

f5b1abb95d60087e32519119120e2744.png

Size

889mmx1148mmx557mm


Environmental requirement:

service environmentarea/altitude/Minimum and maximum temperatures

Air temperature: Maximum  temperature: +85; Minimum temperature:-45

Humidity: Monthly average humidity 95%; Daily average humidity 90%

Altitude above sea level: Maximum installation altitude: 2500m or more higher.

Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. No frequent violent shake


Product show:

14101732568.jpg


 What is a tank circuit breaker compressed air interrupter?

Working Principle:

  • Working Principle: During the opening operation of the circuit breaker, the moving contact compresses the SF₆ gas within the arc quenching chamber, increasing the gas pressure and causing it to flow rapidly toward the arc region. The high-speed gas flow blows and cools the arc, effectively extinguishing it. During the closing operation, the gas returns to its original state as the moving contact moves in the opposite direction.

Features:

  • Excellent Interrupting Performance: The pressurized arc quenching chamber offers excellent interrupting performance, with a short arcing time and long electrical life.

  • Multiple Interruptions: It can continuously interrupt large short-circuit currents at rated voltage multiple times without frequent maintenance.

  • High Mechanical Reliability: The design ensures high mechanical reliability.

  • Suitable for High Voltage Systems: It is suitable for transmission and distribution systems operating at 40.5 kV and above. For example, the LW8-40.5 type SF₆ circuit breaker uses a pressurized arc quenching chamber.




Documentation Resource Library
Restricted
15kV Switching Station requirements in Ethiopia
Other
English
Consulting
Consulting
Restricted
Pole-Mounted SF6 Load Break Switch(LBS) Catalog
Catalogue
English
Consulting
Consulting
Restricted
Pole Mounted Load Break Switch(LBS) Manual operation
Installation Manual
English
Consulting
Consulting
Restricted
15/27kV SF6 Load break switch(LBS) technology specification
Technical Data Sheet
English
Consulting
Consulting
Restricted
SEC SPECIFICATION FOR MV SMART LINE SECTIONALIZER
Other
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.