• 15kV Indoor MV Digital Vacuum Circuit Breaker
15kV Indoor MV Digital Vacuum Circuit Breaker
discuss personally
Model
PacT-15-2000
Basic info
Brand Schneider
Model NO. 15kV Indoor MV Digital Vacuum Circuit Breaker
Rated voltage 15kV
Rated normal current 2000A
Rated frequency 50/60Hz
Series EvoPacT
Product Detail

Description:

The next generation, natively digital CB for panel builders and users of MV switchgear in Primary Distribution applications. Includes scalable connectivity, with integrated sensors, IoT and a HMI that enables remote digital operation from outside of the arc flash zone. Anticipate and detect abnormal conditions with 24/7 condition monitoring and best-in class interlocking for a safety first approach. Durable and designed for life, all compliant with latest industry cybersecurity standards.

EvoPacT medium voltage (MV) breakers are integrated with embedded sensors for proactive health monitoring, inside of SureSeT Metal-Clad switchgear, helping data and controls become visible locally or remotely for increased efficiency and reduced risk.

EvoPacT breakers are designed to be smaller and stronger, built for 26" wide sections for space savings, and increased mechanical testing for reliability. EvoPacT can be easily scaled and upgraded to accommodate your growing needs.

Product specifications:

  • Tested to 3X the industry standard, with 30,000 mechanical operations and a newly designed vacuum interrupter (tested to 30,000 operations at rated current)

  • IEEE/ANSI, UL/UR rated, and compliant with industry cybersecurity standards

  • EvoPacT digital circuit breakers work with your connected solutions. By collecting and analyzing performance data, you can optimize operations throughout your facility

  • EvoPacT’s comprehensive monitoring and control platform is accessible through a connected device and is compliant with industry cybersecurity standards

  • Designed to be modular, flexible, and easily upgraded, EvoPacT digital circuit breakers come in a scalable range of connectivity tiers, to fit your growing needs

  • Sensors, monitoring, and control features are easily scaled. Upgrading is a smooth process, available when your facility is ready

  • Green Premium certified, part of our commitment to deliver sustainable performance for our customers

 Technical Characteristics:

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
10 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!