• PMSet U-Series: Three-Phase Recloser
PMSet U-Series: Three-Phase Recloser
discuss personally
Model
PMSet U-15
Basic info
Brand Schneider
Model NO. PMSet U-Series: Three-Phase Recloser
Rated voltage 15kV
Series PMSet U
Product Detail

 Overview

The PMSet U-Series circuit breaker is controlled and monitored by either the COMPACT or ULTRA PowerLogic ADVC Controller (ADVC). Enclosed in a stainless steel or mildsteel enclosure coated with zinc rich epoxy and special powder paint system PowerLogic ADVC provides an electronic controller with Operator Interface (O.I.) that monitors the circuit breaker and provides protection, measurement, control, and communication functions. Connected via a control cable, the switchgear and PowerLogic ADVC can form a remotely controlled and monitored 
ACR.

 Function

The switchgear is operated by a magnetic actuator that produces an opening and closing action. Switching occurs when a controlled pulse is sent to the open/close actuator from storage capacitors in the PowerLogic ADVC. When closed, the switch is latched magnetically. Spring loaded push-rods provide contact loading on the interrupters. A Current Transformer (CT) and two Capacitive Voltage Transformer (CVT) are molded to the epoxy pole. These are monitored by the PowerLogic ADVC for protection, remote monitoring, and display. An auxiliary voltage supply of 115/230 V AC is required to power the control unit. Where this is inconvenient, an additional voltage transformer can be provided. The recloser is provided with terminal nemapad connectors or an optional cable clamp. Mounting brackets for surge arresters are optionally available. The switchgear contact position is shown by a large, clearly visible external pointer. 
The main tank is equipped with a manual trip lever that can be operated from ground level by a hook stick which performs open and lockout simultaneously. The mechanical lever electronically inhibits both local and remote closing. The position of the lever is indicated to the PowerLogic ADVC by an associated micro- switch. The manual trip ring remains in the down position until physically returned to the normal position by the operator. The PowerLogic ADVC interfaces to the switchgear via the control cable and connects to the Switch Cable Entry Module (SCEM) in the base of the tank via a covered plug/socket sealing arrangement on both the PowerLogic ADVC and the switchgear. The SCEM uses non-volatile memory to store the relevant calibration data, ratings, and number of operations. The SCEM also provides the first stage of electrical isolation and shorting electronics too short the CTs and CVTs in the event the control cable is disconnected while current is flowing through the switchgear.

Recloser Specifications

ADVC Overview

Advanced protection, data logging, and communications capabilities are made possible by the technology housed inthe PowerLogic ADVC. It has been designed especially for outdoor pole mounted operation and is typically mounted low on the pole for ease of access by operation personnel.

ADVC Functions
With a cubicle designed to minimize temperature rise from solar heating, the
stainless steel or mildsteel enclosure, or enclosed in a mild steel enclosure coated with zinc rich epoxy and special powder paint system is used to mount the Control and Protection Enclosure (CAPE), Power Supply Unit (PSU),customer accessories, and Operator Interface.The PowerLogic ADVC Series incorporates the functions of a multi-function protection relay, a circuit breaker controller, a metering unit, and a remote terminal unit.Batteries are carefully located underneath these modules to help avoid overheating so that a battery life of up to 5 years(1) can be achieved. A vandal resistant lockable stainless steel or mild steel door, sealed with a rubber gasket,provides access to the operator interface. Vents are screened against verminentry and the electronic parts are enclosed in a sealed die-cast enclosure which helps protect them from the entry of moisture and condensation for a long lifetime.
The COMPACT cubicle is suitable for temperatures from -10 to 50 °C, while the
option of a battery heater in the ULTRA extends its operating temperature range from -40 to 50 °C.A built-in microprocessor controlled power supply provides uninterrupted operation of not only the circuit breaker and controller, but also the communications radio or modem. These accessories are connected to a built-in user programmable radio power supply. Therefore, no other power supplies are required for connection into your SCADA or Distribution Automation System.Due to careful design the efficiency of the parts is high, allowing a lead-acid battery hold-up time of up to 46 hours(2). The LiFePO4 Battery of the controller can offer 43 hours of hold up time(3).The architecture used has the advantage that the circuit breaker operation is independent of the high voltage supply, relying on a set of capacitors charged by the auxiliary supply.Due to sophisticated power supply management techniques, a circuit breaker operation will operate when attempted, and alarms are raised over the telemetry when auxiliary power is lost. Communications equipment can be mounted within the PowerLogic ADVC cubicle. RS-232 and Ethernet TCP/IP are provided asstandard to support your communications needs.

ADVC Specifications

The PowerLogic ADVC series is available in two models:
•
ULTRA
•
COMPACT
The following table outlines some of the differences between the two models:

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High voltage/Low voltage
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
10 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download