Modulêre UpS ononderbroke kragtoevoer

  • Modular UPS emergency power supply

Sleutelkenmerke

Handelmerk Switchgear parts
Modelnommer Modulêre UpS ononderbroke kragtoevoer
Gedraaide frekwensie 50/60Hz
Uitvoer-spanning 380/400/415VAC
Ingangspanning 380/400/415VAC
Kapasiteit 90kVA
Reeks HBM

Produkbeskrywings van die voorsienier

Beskrywing

HBM50-600KW is 'n nuwe generasie drie-in-drie-uit modulêre UPS wat deur ons maatskappy vrygestel is. Die produk gebruik digitale beheer, modulêre ontwerp en N+X parallele redundansietegnologie, wat die mees gevorderde tegnologiese prestasies in die velde van krag-elektronika en outomatiese beheer integreer. Dit is 'n maatstafprodukt in die veld van modulêre UPS.
Die produkkapasiteit dek verskeie kragspande tussen 50kW en 600kW, wat dit gemaklik maak vir gebruikers om dit soepel te konfigureer en geleidelik te beleg. Dit kan tot 4 parallelle masjiene tot 2400kW hardloop.

Produkkeienskappe

Tegniese spesifikasies
Al die dele van die argitektuur word digitaal beheer, met uitmuntende prestasie en hoë stelselstabiliteit. Dit het selfbeskerming en foute-diagnosevermoë, terwyl dit ook die risiko van analoogtoestel foute vermy, wat die beheersisteem meer stabiel en betroubaar maak.
Geavanceerde drievlak-tegnologie word aangewend, waardeur die algehele effektiwiteit van die masjien so hoog as 96% is.
Hoë kragdichtheidsontwerp, 50KW enkele module grootte (W × D × H) 440 × 620 × 130mm.
Die uitset kan volledig ongebalanceerde las koppel. Wanneer die uitset aan 'n ongebalanceerde las gekoppel word, is die insetstroom in drie fase gebalanseerd, wat die belasting van die driefase kragnetwerk kan balanseer.
hoë betroubaarheid
Die N+X parallele redundansie-ontwerp verseker 'n stelselbeskikbaarheid van 99.999% en 'n MTBF van meer as 250000 ure, wat die hoë betroubaarheidsvereistes van kritieke las op die kragvoorsysteem bevredig; Die soepel parallele redundansie-instelling laat toe dat die stelsel maksimum uitsetkapasiteit lewer.
Beheersisteem parallele redundansie, met beheermetodes van verdeelde beheer en gesentreerde bestuur; Die gesentreerde beheereenheid is redundante parallel gekoppel, en die foute van een daarvan het geen impak op die algehele operasie van die masjien nie; Die geoptimeerde verdeelde kombineringskas verseker die veiligheid van die stelsel se parallele verbinding.
Die gesentreerde moniteringmodule het 'n warmswopfunksie. Wanneer die moniteringmodule uitgehaal word, kan die stelsel normaal werk deur gebruik te maak van gesentreerde bypass-kragvoorsiening, wat die kragvoorsieningsvermoë van die bypass-kragvoorsiening verbeter.
EPO funksie, druk die EPO-knop in noodsituasies om spoedig af te sluit; Die EPO-knop is vir beskerming ontwerp en het 'n verre noodafsluit (REPO) funksie om perongeluk bediening te vermy.
Gemaklik en soepel
Modulêre ontwerp, bestaande uit 1 tot 12 modules wat parallel gekoppel is, met 'n maksimum krag van 600kW. Gebruikers kan geleidelik die aantal modules verhoog; Deur gebruik te maak van warmswop-tegnologie, kan modules aanlyn bygevoeg en verwyder word, wat "nul" onderhouds tyd bereik.
Die onderhouds tyd is kort. Die aantal defektiewe modules is minder of gelyk aan die aantal redundante modules, en die onderhouds tyd is nul; Die aantal defektiewe modules is groter as die aantal redundante UPS-modules, en die onderhouds tyd mag nie meer as 5 minute oorskry nie.
Die kabinet LCD-aanraakkleurenskerm toon ryk UPS-statusinligting, waarskuwinginligting, foutinligting, ens.; Enkele module LED-weergawe, waardeur gebruikers die werkingstoestand van die module deur middel van die module LED-ligte kan verstaan.
In noodsituasies kan die UPS na die onderhouds bypass-kragvoorsiening switsoor, en onderhoudspanne kan veilig aanlyn herstel verrig.

intelligente ontwerp
Die laai-stroom kan ingestel word, en die gebruiker konfigureerde batteriekapasiteit en laai-stroom kan deur middel van die paneel LCD ingestel word om outomatiese gladde switsoer tussen konstante spanningslaai-modus, konstante stroomlaai-modus, en float-laai-modus te bewerkstellig.
Intelligente laai-metode, wat gebruik maak van geavanceerde twee-stadium drie-stadium laai-metode, kan doeltreffend die doelwitte van vinnige laai en verlenging van batterylewebalans, wat die gebruiker se batteriebelegging spaar.
Verskaf 'n wyd verskeidenheid opsionele toerusting, insluitend isolasietransformateurs, verspreidingspaneel, SNMP-kaarte, rel droëverbinding kaarte, ens., om 'n klein tot mediumgrootte verspreidingsstelsel te vorm.
Groen Ontwerp
Deur 'n 19 duim standaardkabinet te gebruik, pas dit perfek by die toepassingsomgewing van die rekenaarkamer en spaar die gebruikbare area van die rekenaarkamer.
Parallelle deling van batterye vermindert die aantal batteriekonfigurasies aansienlik, wat aan gebruikers moontlikheid gee om batterye volgens hul backup-tyd volledig te konfigureer.
Die aantal buitebatterye is opsioneel, en gebruikers kan volgens hul behoefte 30/32/34/36/38/40/42/44/46/48/50 selle (30-50 selle is opsioneel) kies.

Tegniese spesifikasies

Model HBM90-30 HBM150-30 HBM300-30
Capacity      
UPS Cabinet 30-90kVA 30-150KVA 30-300KVA
Power Module 30kVA 30kVA 30kVA
Input      
Input Mode Three-phase Four-wire + Ground
Rated Voltage 380/400V/415Vac
Voltage Range 208~478Vac
Frequency Range 40~70Hz
Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%, +15%, +20%)
 
400 upper limit: 20% (optional +10%, +15%)
 
415 upper limit: 15% (optional +10%)
 
Lower limit: -45% (optional -20%, -30%)
 
Bypass frequency protection range: ±10%
Input Current Harmonic ≤3% (100% Non-linear Load)
Output  
Output Mode Three-phase Four-wire + Ground
Rated Voltage 380/400V/415Vac
Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency  
Mains Mode Synchronous with input; when mains frequency exceeds maximum ±10% (can be set to ±1%, ±2%, ±4%, ±5%), output frequency is 50×(±0.2%)Hz
Battery Mode (50/60±0.2%)Hz
Load Crest Factor 3:1
Switching Time Mains mode to bypass mode: 0ms (tracking); Mains mode to battery mode: 0ms
Overload Capacity Load ≤110%, 60min; ≤125%, maintain 10min; ≤150% maintain 1min; ≥150% switch to bypass immediately
Output Voltage Harmonic ≤2% (100% Linear Load)
Efficiency 95% in Normal Mode
Communication Interface RS232, RS485, 2 Intelligent Slot (Smart Card Slot), Dry Contact
Battery  
Battery Voltage ±192V±204V±216V±228V±240V DC; (32, 34, 36, 38, 40 cells optional)
Charging Current  
UPS Cabinet 30A Max. 50A Max. 100A Max.
Power Module 10A Max. 10A Max. 10A Max.
Working Environment      
Working Temperature 0℃ ~ 40℃ 0℃ ~ 40℃ 0℃ ~ 40℃
Relative Humidity 0 ~ 95% non condensing
Storage Temperature -25℃ ~ 55℃
Altitude < 1500m < 1500m < 1500m
Physical Characteristics  
Appearance Dimensions (D×W×H) mm      
Cabinet 840 x 600 x 1400 840 x 600 x 1400 1100 x 600 x 2000
Module 580 x 443 x131 580 x 443 x131 580 x 443 x131
Weight (Net Weight) Kg      
Cabinet 158 170 305
Module 30K module, 33.5KGS
Execution Standard CE,EN/IEC 62040-2, EN/IEC 62040-1-1, YD/T1095-2008

 

Model HBM300-50 HBM400-50 HBM500-50 HBM600-50
Capacity        
Cabinet 50-300KW 50-400KW 50-500KW 50-600KW
Module 50KW 50KW 50KW 50KW
Maximum Number of Modules 6 8 10 12
Input  
Main Path Input  
Rated Input Voltage (Vac) 380/400/415
Input Voltage Range (Vac) 138 ~ 485Vac
Wiring Mode Three-phase Five-wire
Input Frequency Range (Hz) 40-70
Input Power Factor ≥0.99
Input Current Harmonic (THDi) ≤3% (100% Linear Load)
Bypass Input  
Rated Input Voltage (Vac) 380/400/415
Input Voltage Range (Vac) 220 upper limit: 25% (optional +10%, +15%, +20%) 230 upper limit: 20% (optional +10%, +15%) 240 upper limit: 15% (optional +10%) lower limit: -45% (optional -10%, -20%, -30%)
Wiring Mode Three-phase Five-wire
Bypass Synchronous Tracking Range (Hz) ±10%
Generator Input Supported
Power Walking In Supported
Bypass Reverse Feeding Supported
Output  
Voltage (Vac) 380/400/415±1%
Power Factor 1
Frequency (Hz)  
Mains Mode ±1%/±2%/±4%/±5%/±10% (Configurable)
Battery Mode (50/60±0.1%)Hz
Waveform Sine Wave
Current Crest Ratio 3:1
Output Voltage Harmonic (THDV) ≤2% (100% Linear Load); ≤3% (100% Non-linear Load)
Switching Time (ms) 0
Overall Efficiency (%) 96
Overload Capacity 110% load, transfer to bypass after 60min; 125% load, transfer to bypass after 10min; 150% load, transfer to bypass after 1min
Battery  
Maximum Module Charging Current (A) 20
Battery Voltage 30~50 cells optional, default 36 cells; optional voltages: ±180V/±192V/±204V/±216V/±228V/±240V/±252/±264/±276/±288/±300Vdc (30/32/34/36/38/40/42/44/46/48/50 cells)
Environment  
Working Temperature 0℃ ~ 40℃
Storage Temperature —25℃ ~ 55℃
Humidity Range 0 ~ 95% (Non-condensing)
Working Altitude < 1500m (Derate for use above 1500m)
Noise (1m Distance) <68dB <70dB <70dB <70dB
Other Functions        
Protection Functions Short circuit, overload, over temperature, output over voltage, battery under voltage, fan fault alarm, bypass reverse feeding, lightning protection
Alarm Functions Mains abnormality, overload, UPS fault, battery under voltage and other multiple alarm functions
Communication Functions CAN, RS485, Network Interface, Dry Contact, Parallel Interface, LBS Interface, Smart Card Slot, Temperature Sensor Interface
Mechanical Characteristics  
Dimensions (W×D×H)  
Cabinet (mm) 600×850×2000 600×850×2000 (Standard); 1200×850×2000 (Fully Loaded) 1200×850×2000 1200×850×2000
Module (mm) 440×620×130
Net Weight  
Cabinet (kg) 260 280/600 645 720
Module (kg) 32
Execution Standard YD/T 2165-2010
FAQ vir
Q: Watter voordele het die HBM-reeks modulêre UPS in vergelyking met tradisionele toren-UPS?
A:

In vergelyking met tradisionele toren-UPS het dit duidelike voordele: ① Vlugtige uitbreiding: Kapasiteit kan verhoog word deur modules op vraag by te voeg, wat oorspronklike oorbelegging vermy; ② Hoë betroubaarheid: N+X-oorbodigheidsontwerp elimineer enkele-punt-falings, en heetverwisselbare modules verminder MTTR (gemiddelde tyd tot herstel) na minute; ③ Energiebesparing: AC-AC-effek tot 97%, ECO-modus effek tot 99%; ④ Ruimtebesparing: Hoë kragdigdigheidsontwerp (bv. 60kW-module in 3U-ruimte) bespaar installasie-ruimte; ⑤ Gemaklike instandhouding: Onafhanklike module-ontwerp vereenvoudig foute-diagnose en -vervanging.

Q: Wat is die kernfunksie en werkprinsipe van die HBM reeks modulêre UPS?
A:

 Die kernfunksie is om hoëbetroubare ononderbroke kragverskaffing vir kritiese lasse te verskaf, met die voordele van buigsame kapasiteitsuitbreiding en min onderhoud. Die werkprinsipe is gebaseer op N+X redundante paralleltegnologie: elke kragmodule werk onafhanklik en verdeel die las eweredig; wanneer die hoofstroom normaal is, stabiliseer dit die spanning, filter harmonieke en verskaf krag aan lasse terwyl batterye oplaai; wanneer die hoofstroom misluk, swaar dit oor na batteriekragverskaffing met 'n omskakelingstyd van 0ms. Mislukte modules kan warm-uitgeruil word sonder dat die stelsel afgesluit word, wat 99.999% stelselbeskikbaarheid verseker.

Ken u lewerancier
Online winkel
Punte tydlewering
Reaksietyd
100.0%
≤4h
Bedryfsomsig
Werkplek: 1000m² Totale personeel: Hoogste Jaarlikse Uitvoer (VSA): 300000000
Werkplek: 1000m²
Totale personeel:
Hoogste Jaarlikse Uitvoer (VSA): 300000000
Dienste
Geselsaakstype: Verkope
Hoofdskategorieë: Toerustingkomponente/Toerusting vir inspeksie/Hoëspanningstoerusting/Laagspanningstoerusting/Meetinstrumente/Produksie-toerusting/Elektriese goudartikels
Levenslange garantiebeheerder
Heel Lewensorg Sorg Dienste vir toerustingverskaffing, gebruik, instandhouding en naverkoop, om veilige bedryf van elektriese toerusting, deurlopende beheer en sorgvrye elektrisiteitsverbruik te verseker
Die toerustingverskaffer het platformkwalifikasiesertifisering en tegniese evaluering deurgegaan, wat aan die bron nakoming, professionele standaarde en betroubaarheid verseker.

Verwante produkte

Verwante Kennis

  • Hoofdtransformator-ongelukke en liggasbedryfsprobleme
    1. Ongelukverslag (19 Maart 2019)Op 19 Maart 2019 om 16:13 het die moniteringagtergrond 'n liggasaksie van Hooftransformator nr. 3 gerapporteer. In ooreenstemming met die Reguitlyne vir die Bedryf van Kragtransformatore (DL/T572-2010), het bedryf en onderhoud (B&O) personeel die toestand van Hooftransformator nr. 3 ter plaatse geïnspekteer.Bevestiging ter plaatse: Die WBH nie-elektriese beskermingspaneel van Hooftransformator nr. 3 het 'n Ligfas B gasaksie van die transformatorliggaam gerapp
    02/05/2026
  • Fouten en Handhaving van Enkelefasig Gronding in 10kV Verspreidingslyne
    Kenmerke en opsporingsapparatuur vir enkelfase-grondsluitingsfoute1. Kenmerke van enkelfase-grondsluitingsfouteSentrale waarskuwingsseine:Die waarskuwingklokkie lui, en die aanwyslamp met die etiket “Grondsluiting op [X] kV-busafdeling [Y]” gaan aan. In stelsels met ’n Petersen-kolf (boogonderdrukkingkolf) wat die neutraalpunt grond, gaan die “Petersen-kolf in werking”-aanwyslamp ook aan.Aanwysings van isolasie-toepassingsvoltmeter:Die spanning van die gefouteerde fase da
    01/30/2026
  • Neutralpunt-grondingbedryfmodus vir 110kV~220kV kragroostertransformasies
    Die inligtingsstruktuur van die nulpunt-grondingoperasie vir 110kV~220kV-kragsentrafo's moet aan die isolasieverdraagskap van die transformernulpunte voldoen, en dit moet ook probeer om die nulvolgordeimpedansie van die transformators basis onveranderd te hou, terwyl daar verseker word dat die nulvolgorde-komplekse impedansie by enige kortsluitpunt in die stelsel nie drie keer die positiewe volgorde-komplekse impedansie oorskry nie.Vir 220kV en 110kV-transformers in nuwe konstruksie- en tegnolog
    01/29/2026
  • Waarom gebruik substasies stene grondstof kiepe en verpletterde rots?
    Waarom gebruik substasies stene, grond, kiepsteentjies en verpletterde rots?In substasies vereis toerusting soos krag- en verspreidingstransformateurs, oordraaglyne, spanningstransformateurs, stroomtransformateurs en afsluiters alle aarding. Behalwe aarding, gaan ons nou in diepte in op die rede waarom grond en verpletterde steen algemeen in substasies gebruik word. Alhoewel hulle gewoon voorkom, speel hierdie stene 'n kritieke veiligheids- en funksionele rol.In die ontwerp van substaasie-aardin
    01/29/2026
  • Waarom moet die transformatorkern slegs by een punt aangesluit word? Is nie meerdere punte van aansluiting betroubaarder nie
    Waarom moet die transformator kern aan die grond verbonden word?Tydens bedryf is die transformator kern, saam met die metalstrukture, dele en komponente wat die kern en windings vasmaak, almal in 'n sterk elektriese veld geplaas. Onder die invloed van hierdie elektriese veld verkry hulle 'n relatief hoë potensiaal ten opsigte van die grond. As die kern nie aan die grond verbonden word nie, sal daar 'n potensiaalverskil tussen die kern en die aangeklampde strukture en tank bestaan, wat tot onafha
    01/29/2026
  • Verstaan van Transformer Neutrale Aarding
    I. Wat is 'n Neutrale Punt?In transformateurs en generators is die neutrale punt 'n spesifieke punt in die wonding waar die absolute spanning tussen hierdie punt en elke buite terminal gelyk is. In die diagram hieronder stel puntOdie neutrale punt voor.II. Waarom Moet die Neutrale Punt Aangesluit Word?Die elektriese verbindingsmetode tussen die neutrale punt en die aarde in 'n driefase AC kragstelsel staan bekend as dieneutrale aansluitingmetode. Hierdie aansluitingmetode beïnvloed direk:Die vei
    01/29/2026
Nog nie die regte verskaffer gevind nie? Laat goedgekeurde verskaffers jou vind. Kry Praatskaart Nou
Nog nie die regte verskaffer gevind nie? Laat goedgekeurde verskaffers jou vind.
Kry Praatskaart Nou
Stuur navraag
+86
Klik om lêer op te laai
Laai af
Kry die IEE-Business-toepassing
Gebruik die IEE-Business app om toerusting te vind kry oplossings verbind met kenners en neem deel aan bedryfsamenwerking waar en wanneer ook al volledig ondersteunend van jou kragprojekte en besigheidsgroei