Search


JZW-72.5 Outdoor Voltage Transformer

  • JZW-72.5 Outdoor Voltage Transformer

Key attributes

Brand HK Electrical
Model NO. JZW-72.5 Outdoor Voltage Transformer
Rated frequency 50/60Hz
Primary voltage 66/√3kV
Secondary voltage 110/√3V
Series JZW
Description

Product Overview

JZW-72.5 voltage transformer, epoxy resin casting and outdoor installation, is widely used for measuring current, electric energy and protective relaying in the power system with the frequency of 50Hz or 60 Hz and rated voltage of 66kV or 69kV.

The product can be operated on many circumstances such as the areas of altiplano, tropical area, chillness, coastland and dirtiness etc.

Key Features

  • High Voltage Rating Adaptability:With a rated voltage of 72.5kV, it is specially designed for medium-to-high voltage outdoor substations, enabling precise system voltage measurement to meet metering, protection, and monitoring needs of grids up to 72.5kV.

  • Fully Sealed Weather-resistant Structure:Featuring silicone rubber composite insulators and a stainless steel housing, it achieves IP67 protection rating, offering excellent moisture, dust, and salt fog resistance. It withstands strong UV radiation and extreme temperatures from -40℃ to +70℃, adapting to harsh outdoor environments like deserts and coastal areas.

  • Anti-fouling Flashover & Explosion-proof Design:With external insulation creepage distance ≥35mm/kV, anti-fouling flashover skirts, and a hydrophobic coating, it suits Class Ⅳ pollution areas. Certified to IEC 60076-11 explosion-proof standards, it integrates a pressure relief device to ensure no explosion risk during faults.

  • High-precision Voltage Transformation:Utilizing low-loss silicon steel sheets and foil winding technology, it maintains voltage ratio error ≤0.2% and phase difference ≤10', meeting 0.2-class metering accuracy requirements to provide precise voltage data for power grids.

  • Low Power Consumption & Long Lifespan:With no-load loss ≤60VA and load loss ≤150VA, it saves 15% energy compared to traditional transformers. The epoxy resin casting insulation system ensures a 40-year service life, reducing replacement frequency and O&M costs.

Main technical parameter

  • Highest voltage for equipment: 72.5kV

  • Rated primary voltage: 66/√3kV or 69/√3kV etc

  • Limiting output :2000VA

  • Rated power-frequency withstand voltage: 140kV

  • Rated lightning impulse withstand voltage: 325kV or 350kV

  • Rated insulation level: 72.5/140/325kV or  72.5/140/350 kV

  • Technical standard accords with IEC 60044-2:2003 Part2 Instrument transformers-Part2: inductive voltage transformers or IEEE STD C57.13-2008

JZW-72.5 Outdoor Voltage Transformer

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: 100 Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Power Wire and Cables/Medium and High Voltage Switchgear/Low Voltage Electrical Components/Renewable Energy and EV Charging/Electrical Testing and Metering/Power Generation and Backup Systems/Overhead Line Hardware/Instrument Transformers and Sensors/Transformer and Switchgear Parts/Construction Equipment and Tools/Electrical Manufacturing and Factory Automation/Cable Accessories/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear/Power Quality Equipment
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register