• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Yuqori chastotali onlayn UPS (3 faza kirish va 3 faza chiqish)

  • High frequency on-line UPS (3phase in and 3phase out)

Asosiy xususiyatlari

Бренд Switchgear parts
Модель рақами Yuqori chastotali onlayn UPS (3 faza kirish va 3 faza chiqish)
Quvvat 10KW
Tezlik oraligi 50/60Hz
Ko'rsatkich 10kVA
Серия HBGS

Taomatchilar tomonidan taqdim etilgan mahsulot tavsiflari

Tavsif

HBGS seriyasi eng so'nggi texnologiyalarning asosiy xususiyatlarini to'liq ifodalaydi. Barcha qurilma dunyodagi eng yuqori DSP raqamli boshqarish texnologiyasi va juda yuqori chastotadagi boshqarish texnologiyasidan foydalanadi, shuning uchun kichik hajm, o'zgina vazn va yuqori samaradorlik: nol o'zgartirish dizayni va toza sinusoidal chiqish texnologiyasi foydalanuvchi qurilmalarining turli qurilmalarga mos kelishini ta'minlaydi. Aniq AC-DC o'zgarish shakli orqali jamiy elektr tarmogidagi chiqish arusi va shiddatini tekshirish uchun ishlatiladi. Yuqori chastota pulsdor eni modulyator orqali kirish energiya manbasi arusini shunalarni shiddati bilan sinxronlashtirish orqali 95% dan yuqori kirish energiya faktori ko'rib chiqiladi. Oddiy holatlarda, jamiy elektr tarmoqdan DCBUS DC voltajini AC-DC shema orqali olinadi. DCBUS keyin inversiyaning orqali AC chiqishga aylanadi va barcha yuklar toza sinusoidal energiya manbasi orqali barqarorlashtiriladi va shumdan tozalangan. A'lolik! GBT, UPS inversiyalari ishlash chastotasini 40KHz ga yetkazish imkoniyatini beradi, bu inversiyaning samaradorligini va UPSning umumiy samaradorligini oshiradi. Inversiya chastotasi oshishi inversiyaning shumini kamaytiradi. Shuning uchun, HBG seriyasi UPS-ni kompyuter xonasiga o'rnatsangiz, ishingizga ta'sir qilmaydi. Onlayn yuqori chastotadagi HBG seriyasi UPS RS232 aloqa interfeysi orqali tarmoq serveriga ulanadi va energiya monitoring dasturi orqali real vaqtli energiya holatini taqdim etadi. Bu, automatk holda saqlanish, avtomatik vaqtlangan yoqish/ochish, energiya holatini yozish kabi intellektual funksiyalarni amalga oshiradi, shunday qilib, inson-mashina aloqasini ta'minlaydi. Jamiy elektr tarmoq kesilganda, UPS serverga ochishni tayyorlash haqida xabar beradi va avtomatik ravishda barcha ma'lumotlarni diskka saqlab, normal ochish buyrug'ini bajaradi. Har qanday nazorat qilinmagan tarmoq mavjud bo'lganda ham, tarmoq sistemadagi ma'lumotlar xavfsizligini ta'minlaydi

Qo'llanish sohalar

Tarmoq boshqaruv markazlari va kompyuter markazlari, bank va hisob-kitob, soliqlar, aloqa, pochtada, radio va televideoda, davlat himoyasida, transportda. Elektr, sog'liqni saqlash, sanoat boshqaruv va milliy himoya kabi muhim ma'lumot sohalarida keng qo'llaniladi.

 

Texnik parametrlar

Model Specification 10KH(S) 15KH(S) 20KH(S) 30KH(S) 40KH(S) 60KH(S) 80KS 100KS 120KS 160KS 200KS
Phase Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output Three-Phase Input and Output
Capacity 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW 80KVA/80KW 100KVA/90KW 120KVA/108KW 160KVA/144KW 200KVA/180KW
Input                      
Rated Voltage 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N) 3 × 400 VAC (3Ph+N)
Voltage Range 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) 190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load)
Frequency Range 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz
Power Factor ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load ≥ 0.99 @ 100% load
Output                      
Output Voltage 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N) 3 × 360/380/400/415 VAC (3Ph+N)
Voltage Regulation (Battery Mode) ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1%
Frequency Range (Synchronous Tracking Range) 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz 46~54 Hz or 56~64Hz
Frequency Accuracy (Battery Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max) 3:1 (Max)
Harmonic Distortion ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) ≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load)
Conversion Time                      
Mains to Battery 0 0 0 0 0 0 0 0 0 0 0
Inverter to Bypass 0 0 0 0 0 0 0 0 0 0 0
Waveform (Battery Mode) Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave
Overload                      
Mains Mode 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds
Battery Mode 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds 105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds
Parallel Capacity Up to 3 units in parallel Up to 3 units in parallel Up to 3 units in parallel Up to 3 units in parallel Up to 3 units in parallel Up to 3 units in parallel Up to 2 units in parallel Up to 2 units in parallel Up to 2 units in parallel Up to 2 units in parallel Up to 2 units in parallel
Efficiency                      
Mains Mode 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 94.0% 94.0% 94.0% 94.0% 94.0%
ECO Mode 98.5% 98.5% 98.5% 98.5% 98.5% 98.5% 98.0% 98.0% 98.0% 98.0% 98.0%
Battery Mode 94.5% 94.5% 94.5% 94.5% 94.5% 94.5% 93.0% 93.0% 93.0% 93.0% 93.0%
Battery                      
Standard Unit                      
Battery Model 12V/9Ah 12V/7Ah 12V/9Ah 12V/7Ah 12V/9Ah - N/A N/A N/A N/A N/A
Quantity (Cells) ±10 cells ×1 string ±16 cells ×1 string - ±16 cells ×2 strings - - N/A N/A N/A N/A N/A
Standard Charging Time 4 hours to 90% 4 hours to 90% - 4 hours to 90% - - N/A N/A N/A N/A N/A
Maximum Charging Current 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable - 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable - - N/A N/A N/A N/A N/A
Charging Voltage ±120VDC ±192VDC - ±120VDC/±192VDC - - N/A N/A N/A N/A N/A
Long-term Unit                      
Battery Model - - - Depends on Power Supply Time Depends on Power Supply Time Depends on Power Supply Time - - - - -
Quantity (Cells) ±10 cells ±16~±20 cells (Adjustable) - ±16~±20 cells (Adjustable) ±16~±20 cells (Adjustable) ±16~±20 cells (Adjustable) - - - - -
Maximum Charging Current 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable (Max 12A charging current) - 1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable (Max 12A charging current) 12A 12A 16A 16A - -  
Charging Voltage ±13.65V × Number of Batteries (10) ±13.65V × Number of Batteries (16~20) - ±13.65V × Number of Batteries (16~20) ±13.65V × Number of Batteries (16~20) ±13.65V × Number of Batteries (16~20) - - - - -
Indicator Light                      
LCD Display System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication
Alarm Sound                      
Battery Mode Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds
Low Battery Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second
Overload Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second Beeps every 0.5 second
Error Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep
Physical Performance                      
Standard Unit                      
Dimensions (W×D×H)mm 250X630X750 250X630X750 300 x815 x 1000 300 x815 x 1000 300 x815 x 1000 300 x815 x 1000 N/A N/A N/A N/A N/A
Net Weight (kgs) 109 126 139 225 250 - N/A N/A N/A N/A N/A
Long-term Unit                      
Dimensions (W×D×H)mm 250X630X750 250X630X750 300 x815 x 1000 300 x815 x 1000 360 x 790 x 1010 360 x 790 x 1010 550 x 850 x 1500 550x950x1700 650x1000x2100 - -
Net Weight (kgs) 43 43 43 60 61 108 113 150 185 - -
Operating Environment                      
Operating Temperature 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C 0-40°C
Humidity <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation <95% No Condensation
Noise Less than 65dB @ 1m Less than 65dB @ 1m Less than 65dB @ 1m Less than 65dB @ 1m Less than 65dB @ 1m Less than 65dB @ 1m Less than 75dB @ 1m Less than 75dB @ 1m Less than 75dB @ 1m Less than 75dB @ 1m Less than 75dB @ 1m
Control Management                      
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC
Optional SNMP Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management
*Chiqish kuchlanishi 3x360VAC ga sozlangan bo'lsa, chiqish quvvati 90% gacha kamayadi
*Joriy texnik xususiyatlar oldindan ogohlantirmasdan o'zgartirilishi mumkin
FAQ
Q: 3fazli kirish va 3fazli chiqishga ega bo'lgan yuqori chastotali onlayn UPS boshqa turdagi 3fazli UPS turlariga nisbatan qanday afzalliklarga ega?
A:

 Pastdagi chastotali uchfazal UPS va oflayn uchfazal UPS bilan solishtirganda, bu o'ziga xos konkurentiya afzalliklariga ega: ① Yuqori effektivlik & energiyasaf bo'lish: Yuqori chastotali ikki marta o'zgaruvchan texnologiya past chastotali modellarga nisbatan energiya yo'qotishni 15%~20% ga tushiradi; ECO rejimida effektivlik 96% gacha yetadi, bu esa uzoq muddatli ishlanish xajmlarini o'ta tortadi; ② Kichik hajm & joy saqlash: Kichik hajmi va og'irligi (past chastotali UPSdan 30%~40% ozroq), katta loyihalar uchun (masalan, ma'lumotlar markazlari) o'rnatish joyini saqlaydi; ③ Stabil uchfazali chiqish: Uchfazal yukni (tengsizlik aniqlik ≤25%) moslashtiradi, past harmonik deformatsiya (THD <3%), murakkab quvvatli jihozlar (sanoat boshqaruv tizimlari, tibbiy MRI) uchun qulay; ④ Tez o'zgarish & nol to'xtov: <2ms da bekor qilinadigan akkumulyator energiyasiga o'tish, ishni to'xtatish yoki ma'lumot yo'qotishni oldini oladi; ⑤ Kuchli kengaytirish imkoniyati: 2~8 ta birikma paralel ulash orqali quvvatni kengaytirish, kelajakda yuk o'sishi talablari asosida; ⑥ Axborotlarni avtomatlashtirish: LCD doirlika ekran bilan opshirilgan, masofadan kuzatish (SNMP/Modbus/4G)ni qo'llab-quvvatlaydi, bir nechta UPS birikmalarni markazlashtra shakllantirish.

Q: Yuqori chastotali onlayn UPS (3 fazalik kirish va 3 fazalik chiqish)ning asosiy funksiyasi va ishlash printsipi nima?
A:

 Bu, kuchli elektr energiyasini bekor qilish tizimi bo'lib, uch fazali elektr tarmog'lar uchun mo'ljallangan va katta hajmdagi jihozlar ni tarmoqda paydo bo'lgan anomaliyalardan himoya qilish uchun ishlatiladi. Asosiy funksiyalar: ① O'zgaruvchan tokni, to'siqni, pasayishni, garmonikani va energiya o'chib ketishini ajratib, stabil uch fazali sinusoidal tokni taqdim etish; ② Mavjud elektr tarmog'idan buzilish paytida (nol vaqt talab) batareya energiyasiga bekor qilish orqali (nol vaqt talab) katta yukdagi jihozlarning davom etishi; ③ Uch fazalarni moslashtirish va tarmoq interferentsiyasini oldini olish. Ishlash printsipi: Yuk tizimiga yuborilishi uchun uch fazali sinusoidal tok (toza sinusoidal forma) ga qaytariladigan DC (postoyon tok) ga aylantiriladi; mavjud elektr tarmog'idan buzilish paytida batareya inverterga tezroq (vaqt <2ms) DC energiyasini taqdim etadi; yuqori chastotali dizayn (20kHz~50kHz) UPS-ni nisbatan past chastotali uch fazali UPS-lardan kompaktroq va energiya sifatida samaraliroq qiladi.

Sizning taminotchilaringizni tanishang
Online do'kon
Vaqtida yetkazib berish darajasi
Reaksiya vaqti
100.0%
≤4h
Компания ҳақида кўриб чиқиш
Ish joyi: 1000m² Jamiy hodimlar soni: Eng yuqori yillik eksport (AQSh dollarida): 300000000
Ish joyi: 1000m²
Jamiy hodimlar soni:
Eng yuqori yillik eksport (AQSh dollarida): 300000000
Xizmatlar
Tadbirkor turi: Sotuv
Asosiy kategoriyalar: Jismlar qo'shimchasi/Tekshirish qurilmasi/Yuqori bo'lakli qurilmalar/Pastki elektr tarmog'i/Axborot uskunalari/Ishlab chiqarish uskunalari/Elektr tashkil etuvchi qurilma
Hayot davomida boshqaruv
Elektr jihozlarning xavfsiz ishlashi, uzluksiz nazorat va tashvishsiz elektr iste'moli uchun jihozlar sotib olish, foydalanish, ta'mirlash va keyingi sotuvdan keyingi xizmat ko'rsatish bo'yicha butun umrlik parvarish qilish xizmatlari
Uskuna etkazib beruvchisi platforma sifatidagi tasdiqnomani va texnik baholashni o'tkazgan bo'lib, manbadan boshlab mos kelish, mutaxassislilik va ishonchlilikni ta'minlaydi.

O'xshash mahsulotlar

O'quv materiallari

  • Asosiy transformator hodisalari va yengil gaz ishlayishi muammolari
    1. Kasalilik yozuvlari (19-mart, 2019)19-mart, 2019-yilda soat 16:13 da, monitoring fonida No. 3 asosiy transformatorining oq gaz harakati haqida xabar berildi. Elektr energiya transformatorlarini ishga tushirish qoidalari (DL/T572-2010) asosida, ekspluatatsiya va texnik xizmat ko'rsatish (E&TXK) xodimlari No. 3 asosiy transformatorning holatini tekshirdilar.Mazmunda tasdiqlandi: No. 3 asosiy transformatorining WBH elektrik emas himoya paneli B fazada transformatorning oq gaz harakati haqida
    02/05/2026
  • 10кВ распределитель линияларидаги бир фазали жерга уланиш ва уни бажарISH
    Bir fazali yer qo‘shilish xususiyatlari va aniqlash qurilmalari1. Bir fazali yer qo‘shilish xususiyatlariMarkaziy ogohlantirish signallari:Ogohlantirish chiqqonlari chalinadi va “[X] kV avtobus bo‘limi [Y] da yer qo‘shilishi” deb yozilgan ko‘rsatkich lampochkasi yonadi. Neytral nuqtasi Peterson spirali (yoyni bostirish spirali) orqali yerlangan tizimlarda “Peterson spirali ishlayapti” deb yozilgan ko‘rsatkich ham yonadi.Izolyatsiya nazorati voltmetri ko‘rsatkichlari:Avari
    01/30/2026
  • 110kV~220kV elektr tarmoqlarining transformatorlarining neutral nuqtasini qurilish rejimi
    110kV~220kV elektr tarmoqlarining transformatorlari uchun neutral nuqtaning yerdan ulash rejimlari, transformatorlar neutral nuqtasining izolyatsiya talablarni qanoatlantirishi kerak va substantsiyalarning nol-sekvans impedansini asosan o'zgartirmaydigan holda, tizimning har qanday qisqartma nuqtasidagi nol-sekvans umumiy impedansining musbat-sekvans umumiy impedansidan uch marta ortiq bo'lmaganiga ishonch hosil qilish kerak.Yangi tiklanish va texnologik takomillashtrish loyihalarida 220kV va 11
    01/29/2026
  • Nega Mavjudiyatlar Taşlar Shosheva va Zanjirli Toshdan Foydalanishini Sababini Nima?
    Substationlarda nima uchun tosh, kum, kivach va zavodlangan tosh ishlatiladi?Substationlarda, elektr energiyasi va taqsimot transformatorlari, uzatish liniyalari, voltaj transformatorlari, ampermetrlar va o'chirish shalterlari kabi jihozlar qo'shilish lozim. Qo'shilishdan tashqari, endi tosh va zavodlangan tosh substationlarda ko'pincha ishlatilishi sabablarini yuqori darajada tahlil qilamiz. Ular oddiy ko'rinadigan bo'lsa-da, bu toshlar xavfsizlik va funktsional vazifalarda muhim rol o'ynaydi.S
    01/29/2026
  • Nega qanday sababdan transformatorning markazi faqat bitta nuqtada grounding qilinishi kerak? Bir nechta nuqtalik grounding emasmi ko'proq ishonchli bo'ladimi?
    Transformerning markasi nima sababdan qurilishiga muhtoj?Ishlash jarayonida, transformerning markasi, shu bilan birga markani va spirlarini qamrab turuvchi metall konstruksiyalar, qismlar va komponentlar guvohlikli elektr maydoni ichida joylashgan. Bu elektr maydonining ta'siri ostida ular yer nisbatan nisbiy aniq potentsialni o'zlashtiradi. Agar marka qurilmagan bo'lsa, marka va qurilgan qamrab turuvchi konstruksiyalar va rezervuar orasida potentsial farqi bo'lib qolishi mumkin, bu esa bevosita
    01/29/2026
  • Transformer Noytral Tarmoqlanishini Tushunish
    I. Noytral nuqta nima?Transformatorlarda va generatorlarda noytral nuqta - bu o‘zgaruvchidan har bir tashqi terminalga qadar mutlaq voltaj teng bo'lgan qatordan xususiy nuqta. Quyidagi diagrammadagi O nuqtasi noytral nuqtani ifodalaydi.II. Noytral nuqtaga qanday qilib zamin beriladi?Uch fazali AC elektr tarmog‘idagi noytral nuqta va erkin maydon orasidagi elektr tarmoqlanish usuli noytral zaminlanish usuli deb ataladi. Bu zaminlanish usuli to‘g‘ridan-to‘g‘ri ta'sir etadi:Elektr tarmog‘ining xavf
    01/29/2026
To'g'ri tashkilotni topa olmadingizmi Yetakchi tasdiqlangan tashkilotlar sizni topishsin Hozir soʻrovnoma olish
To'g'ri tashkilotni topa olmadingizmi Yetakchi tasdiqlangan tashkilotlar sizni topishsin
Hozir soʻrovnoma olish
So'rov
+86
Faylni yuklash uchun bosing
Yuklab olish
IEE Business ilovalarini olish
IEE-Business ilovasini ishlatib jihozni qidirish orqali yechimlarni oling muvaffaqiyatlari bilan bog'laning va istalgan joyda va vaqtda sohaniy hamkorlikka qatnashing kuchli elektr energetika loyihalaringiz va biznesingiz rivojlanishi uchun