| Phase |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
Three-Phase Input and Output |
| Capacity |
10KVA/10KW |
15KVA/15KW |
20KVA/20KW |
30KVA/30KW |
40KVA/40KW |
60KVA/60KW |
80KVA/80KW |
100KVA/90KW |
120KVA/108KW |
160KVA/144KW |
200KVA/180KW |
| Input |
|
|
|
|
|
|
|
|
|
|
|
| Rated Voltage |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
3 × 400 VAC (3Ph+N) |
| Voltage Range |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
190-520 VAC (3-phase @ 50% load); 305-478 VAC (3-phase @ 100% load) |
| Frequency Range |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
| Power Factor |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
≥ 0.99 @ 100% load |
| Output |
|
|
|
|
|
|
|
|
|
|
|
| Output Voltage |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
3 × 360/380/400/415 VAC (3Ph+N) |
| Voltage Regulation (Battery Mode) |
± 1% |
± 1% |
± 1% |
± 1% |
± 1% |
± 1% |
± 1% |
± 1% |
± 1% |
± 1% |
± 1% |
| Frequency Range (Synchronous Tracking Range) |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
46~54 Hz or 56~64Hz |
| Frequency Accuracy (Battery Mode) |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Crest Factor |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
3:1 (Max) |
| Harmonic Distortion |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
≤ 2% THD (Resistive Load); ≤ 5% THD (Non-resistive Load) |
| Conversion Time |
|
|
|
|
|
|
|
|
|
|
|
| Mains to Battery |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
| Inverter to Bypass |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
| Waveform (Battery Mode) |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
Pure Sine Wave |
| Overload |
|
|
|
|
|
|
|
|
|
|
|
| Mains Mode |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
| Battery Mode |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
100%-110% for 60 minutes, 110%-125% for 10 minutes, 125%-150% for 1 minute, >150% immediately |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
105-110% for 60 minutes, 111-125% for 10 minutes, 126-150% for 1 minute, >150% for 200 milliseconds |
| Parallel Capacity |
Up to 3 units in parallel |
Up to 3 units in parallel |
Up to 3 units in parallel |
Up to 3 units in parallel |
Up to 3 units in parallel |
Up to 3 units in parallel |
Up to 2 units in parallel |
Up to 2 units in parallel |
Up to 2 units in parallel |
Up to 2 units in parallel |
Up to 2 units in parallel |
| Efficiency |
|
|
|
|
|
|
|
|
|
|
|
| Mains Mode |
95.5% |
95.5% |
95.5% |
95.5% |
95.5% |
95.5% |
94.0% |
94.0% |
94.0% |
94.0% |
94.0% |
| ECO Mode |
98.5% |
98.5% |
98.5% |
98.5% |
98.5% |
98.5% |
98.0% |
98.0% |
98.0% |
98.0% |
98.0% |
| Battery Mode |
94.5% |
94.5% |
94.5% |
94.5% |
94.5% |
94.5% |
93.0% |
93.0% |
93.0% |
93.0% |
93.0% |
| Battery |
|
|
|
|
|
|
|
|
|
|
|
| Standard Unit |
|
|
|
|
|
|
|
|
|
|
|
| Battery Model |
12V/9Ah |
12V/7Ah |
12V/9Ah |
12V/7Ah |
12V/9Ah |
- |
N/A |
N/A |
N/A |
N/A |
N/A |
| Quantity (Cells) |
±10 cells ×1 string |
±16 cells ×1 string |
- |
±16 cells ×2 strings |
- |
- |
N/A |
N/A |
N/A |
N/A |
N/A |
| Standard Charging Time |
4 hours to 90% |
4 hours to 90% |
- |
4 hours to 90% |
- |
- |
N/A |
N/A |
N/A |
N/A |
N/A |
| Maximum Charging Current |
1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable |
1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable |
- |
1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable |
- |
- |
N/A |
N/A |
N/A |
N/A |
N/A |
| Charging Voltage |
±120VDC |
±192VDC |
- |
±120VDC/±192VDC |
- |
- |
N/A |
N/A |
N/A |
N/A |
N/A |
| Long-term Unit |
|
|
|
|
|
|
|
|
|
|
|
| Battery Model |
- |
- |
- |
Depends on Power Supply Time |
Depends on Power Supply Time |
Depends on Power Supply Time |
- |
- |
- |
- |
- |
| Quantity (Cells) |
±10 cells |
±16~±20 cells (Adjustable) |
- |
±16~±20 cells (Adjustable) |
±16~±20 cells (Adjustable) |
±16~±20 cells (Adjustable) |
- |
- |
- |
- |
- |
| Maximum Charging Current |
1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable |
1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable (Max 12A charging current) |
- |
1/2/3/4/5/6/7/8/9/10/11/12A±10% adjustable (Max 12A charging current) |
12A |
12A |
16A |
16A |
- |
- |
|
| Charging Voltage |
±13.65V × Number of Batteries (10) |
±13.65V × Number of Batteries (16~20) |
- |
±13.65V × Number of Batteries (16~20) |
±13.65V × Number of Batteries (16~20) |
±13.65V × Number of Batteries (16~20) |
- |
- |
- |
- |
- |
| Indicator Light |
|
|
|
|
|
|
|
|
|
|
|
| LCD Display |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
| Alarm Sound |
|
|
|
|
|
|
|
|
|
|
|
| Battery Mode |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
Beeps every 4 seconds |
| Low Battery |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
Beeps every 1 second |
| Overload |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
Beeps every 0.5 second |
| Error |
Continuous Beep |
Continuous Beep |
Continuous Beep |
Continuous Beep |
Continuous Beep |
Continuous Beep |
Continuous Beep |
Continuous Beep |
Continuous Beep |
Continuous Beep |
Continuous Beep |
| Physical Performance |
|
|
|
|
|
|
|
|
|
|
|
| Standard Unit |
|
|
|
|
|
|
|
|
|
|
|
| Dimensions (W×D×H)mm |
250X630X750 |
250X630X750 |
300 x815 x 1000 |
300 x815 x 1000 |
300 x815 x 1000 |
300 x815 x 1000 |
N/A |
N/A |
N/A |
N/A |
N/A |
| Net Weight (kgs) |
109 |
126 |
139 |
225 |
250 |
- |
N/A |
N/A |
N/A |
N/A |
N/A |
| Long-term Unit |
|
|
|
|
|
|
|
|
|
|
|
| Dimensions (W×D×H)mm |
250X630X750 |
250X630X750 |
300 x815 x 1000 |
300 x815 x 1000 |
360 x 790 x 1010 |
360 x 790 x 1010 |
550 x 850 x 1500 |
550x950x1700 |
650x1000x2100 |
- |
- |
| Net Weight (kgs) |
43 |
43 |
43 |
60 |
61 |
108 |
113 |
150 |
185 |
- |
- |
| Operating Environment |
|
|
|
|
|
|
|
|
|
|
|
| Operating Temperature |
0-40°C |
0-40°C |
0-40°C |
0-40°C |
0-40°C |
0-40°C |
0-40°C |
0-40°C |
0-40°C |
0-40°C |
0-40°C |
| Humidity |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
<95% No Condensation |
| Noise |
Less than 65dB @ 1m |
Less than 65dB @ 1m |
Less than 65dB @ 1m |
Less than 65dB @ 1m |
Less than 65dB @ 1m |
Less than 65dB @ 1m |
Less than 75dB @ 1m |
Less than 75dB @ 1m |
Less than 75dB @ 1m |
Less than 75dB @ 1m |
Less than 75dB @ 1m |
| Control Management |
|
|
|
|
|
|
|
|
|
|
|
| Smart RS-232/USB |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC |
| Optional SNMP |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |
Power Management Supports SNMP Management and Network Management |