| Marca | Switchgear parts |
| Numerus Modeli | Alta frequentia on-line (typus armarii) uPs alimentatio electrica |
| Voltus egressus | 110-127VAC |
| Tensio ingressus | 110-127VAC |
| Capacitas | 3kVA |
| Series | HBG |
Series HBG plene condensat essentiam technologiae praecipuae. Totum machina adoptat DSP digitalem controlis technologiam et ultra-altae frequentiae controlis technologiam mundi adhibitas. Creat parvam magnitudinem, levem pondus, altam efficientiam designum sine conversione et puram sinusoidalem output technologiam ut tueatur ut apparatus usatoris sit aptus omnibus generibus apparatorum. Unicus circuitus AC-DC conversionis adhibetur ad detegendum currentem et voltantiam output a potestate publica. Per modulatorem altae frequentiae pulsuum latitudinis, currentis forma input potestatis synchronizatur cum forma voltantis ad efficiendum altum input potentiale factorem maius quam 95%. Sub normalibus conditionibus, potestas publica suppeditatur per circuitum ACDC ad obtinendum DCBUS voltantiam DC, quae deinde convertitur in 220V AC output per inverter. Omnes onera utuntur pura sinusoidali potentia electrica, quae stabilizata est in frequentia et filtrata ab strepitu. Optimum IGBT utitur ut elementum conversionis potentiae. Propter altas characteres commutationis IBGT, frequentia operativa UPS inverter attingit 40KH2, meliorans efficientiam inverter et totalem efficientiam UPS. Incrementum frequentiae inverter etiam reducit strepitum inverter. Ergo, ponendo series HBG UPS directe in camera computatoria, non afficiet tuum opus. Series HBG UPS altae frequentiae online conectitur ad server network per RS232 interficem monitoring software turris potestatis, praebens status potentiae omni tempore. Realizat etiam functiones intelligentes sicut temporata autopericia, automatica conservatio, automatica temporata activatio/cessatio, et registratio status potentiae, effectuans communicationem nulli distanti inter homines et machinas. Cum potestas publica interpellatur, UPS notificat server, praeparatur ad cessationem, automatica conservat omnia data, et exsequitur ordines normales cessationis, tueatur securitatem datarum systematis network etiam in ambientibus network sine custode.
Campus applicationis
Largiter adhibitus in campus datarum importantium sicut centra administrativa network et centra computatoria, bancis et secunditatibus, fiscis, communicationibus, postis, radiodiffusionibus et televisionibus, publicis securitatibus, transportibus, electricitatibus, sanitatibus, controlibus industrialibus, et defensionibus.
Parametri technici
| Model | HBG - 1KR (S) | HBG - 2KR (S) | HBG - 3KR (S) | HBG - 6KR(S) | HBG - 10KR(S) |
|---|---|---|---|---|---|
| Phase | Single Phase Input and Output | Single Phase Input and Output | Single Phase Input and Output | Single Phase Input and Output | Single Phase Input and Output |
| Capacity | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | 6000 VA / 4800 W | 10000 VA / 8000 W |
| Input | |||||
| Input Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 208/220/230/240VAC |
| Voltage Range | 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load | 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load | 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load | 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load | 110-300VAC ±3% at 50% load; 176-300 VAC ±3% at 100% load |
| Frequency Range | 40Hz ~ 70 Hz | 40Hz ~ 70 Hz | 40Hz ~ 70 Hz | 40Hz ~ 70 Hz | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
| Power Factor | ≥ 0.99@100% load | ≥ 0.99@100% load | ≥ 0.99@100% load | ≥ 0.99@100% load | ≥ 0.99@100% load |
| Output | |||||
| Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 208/220/230/240VAC |
| Voltage Regulation (Battery Mode) | ±1% | ±1% | ±1% | ±1% | ±1% |
| Frequency Range (Synchronous Correction Range) | 47 ~ 53 Hz or 57 ~ 63 Hz | 47 ~ 53 Hz or 57 ~ 63 Hz | 47 ~ 53 Hz or 57 ~ 63 Hz | 47 ~ 53 Hz or 57 ~ 63 Hz | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
| Frequency Accuracy (Battery Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Crest Factor | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
| Harmonic Distortion | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) |
| Conversion Time | |||||
| AC to DC | None | None | None | None | 0 ms |
| Inverter to Bypass | 4 ms (Standard Conditions) | 4 ms (Standard Conditions) | 4 ms (Standard Conditions) | 4 ms (Standard Conditions) | 0 ms |
| Waveform (Battery Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
| Efficiency | |||||
| Mains Mode | 88% | 89% | 90% | 92% | 93% |
| Battery Mode | 83% | 87% | 88% | 90% | 91% |
| Battery | |||||
| Standard Unit | |||||
| Battery Model | 12V / 9AH | 12V / 9AH | 12V / 9AH | 12V / 9AH | 12V / 9AH |
| Quantity (Cells) | 2 | 4 | 6 | 16 | 20 |
| Standard Charging Time | - | 4 hours to 90% | - | 9 hours to 90% | - |
| Maximum Charging Current | - | 1.0A (Max) | - | Preset:1.0A, Max:2.0A | - |
| Charging Voltage | 27.4VDC ±1% | 54.7VDC ±1% | 82.1VDC ±1% | 218.4VDC ±1%
|
- |
| Long-term Unit | |||||
| Battery Model | - | - | Depends on Power Supply Time | Depends on Power Supply Time | - |
| Quantity (Cells) | 2
|
4 | 6
|
16-20 Grain (adjustable) | - |
| Maximum Charging Current | - | 1.0A,2.0A,4.0A,6.0A | - | 1.0A, 2.0A, 4.0A, 6.0A (adjustable, 6A only applicable to 16 batteries) | - |
| Charging Voltage | 27.4VDC ±1%
|
54.7VDC ±1% | 82.1VDC ±1%
|
109.4VDC±1%
|
- |
| Appearance | |||||
| LCD or LED Display | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication |
| Alarm | |||||
| Battery Mode | Beeps every 4 seconds | Beeps every 4 seconds | Beeps every 4 seconds | Beeps every 4 seconds | Beeps every 4 seconds |
| Low Battery | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second |
| Overload | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second |
| Error | Continuous Beep | Continuous Beep | Continuous Beep | Continuous Beep | Continuous Beep |
| External Dimensions | |||||
| Standard Unit | |||||
| Dimensions (W×D×H)mm | 310 X 438 X 88 | 410 X 438 X 88 | 630 X 438 X 88 | host:530 X 438 X 88【2U】
|
host:580 X 438 X 133【3U】
|
| Net Weight (kg) | 9.9 | 16.9 | 25.6 | host:135
|
host:18
|
| Long-term Unit | |||||
| Dimensions (W×D×H)mm | 310 X 438 X 88 | 410 X 438 X 88 | - | - | - |
| Net Weight (kg) | 5.5 | 8.1 | 8.5 | - | - |
| Operating Environment | |||||
| Temperature and Humidity | Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) | Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) | Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) | Relative Humidity 0-95% and Temperature 0-40°C (No Condensation) | Relative Humidity 0-95% and Temperature 0-40°C (No Condensation) |
| Noise | Less than 50dB@ 1m | Less than 50dB@ 1m | Less than 50dB@ 1m | Less than 55dB @ 1m | Less than 58dB @ 1m |
| Control Management | |||||
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
| Optional SNMP | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management |
*Cum UPS in modum constantis voltaginis et frequentiae constitutus est, potentia output reducetur per 40%. Cum voltagio output UPS constituto ad 208VAC, potentia output reducetur per 10%.
**Cum numerus bateriarum internarum mutatur ad 16-19, machina secundum formulam hanc output reducet: P-PrtiX (N/20x100%).
***Si machina installata est super altitudinem 1000 metrorum, potentia output decrescet per 1% pro incremento 100 metrorum. Si quaevis mutationes ad specificationes producti presentis factae sunt, non dabitur ulterius notitia.