• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


High frequency on-line (rack type) uPs power supply

  • High frequency on-line (rack type) uPs power supply

Key attributes

Brand Switchgear parts
Model NO. High frequency on-line (rack type) uPs power supply
Output Voltage 110-127VAC
Input Voltage 110-127VAC
Capacity 3kVA
Series HBG

Product descriptions from the supplier

Description

HBG series fully condenses the essence of cutting-edge technology. The whole machine adopts the world's advanced DSP digital control technology and ultra-high frequency control technology. It creates a small size, light weight, high efficiency zero conversion design and pure sine wave output technology to ensure that the user's equipment is suitable for all kinds of equipment. A unique AC-DC conversion circuit is used to detect the output current and voltage of the mains power supply. Through a high-frequency pulse width modulator, the current waveform of the input power supply is synchronized with the voltage waveform to achieve a high input power factor greater than 95%. Under normal circumstances, the mains power is supplied through an ACDC circuit to obtain a DCBUS DC voltage, which is then converted into a 220V AC output by an inverter. All loads use a pure sine wave power supply that has been stabilized in frequency and filtered out of noise. Optimal IGBT is used as the power conversion element. Due to the high-frequency switching characteristics of IBGT, the working frequency of the UPS inverter can reach 40KH2, improving the efficiency of the inverter and the overall efficiency of the UPS. The increase in inverter frequency also reduces the noise of the inverter. Therefore, placing the HBG series UPS directly in the computer room will not affect your work. The online high-frequency HBG series UPS is connected to the network server through RS232 flood control interface tower power monitoring software, providing power status at any time. It also realizes intelligent functions such as timed self check, automatic storage, automatic timed power on/off, and recording of power status, achieving zero distance communication between humans and machines. When the mains power is interrupted, UPS notifies the server, prepares to shut down, automatically saves all data, and executes normal shutdown commands, ensuring data security of the network system even in unmanned network environments.

Application field

Widely used in important data fields such as network management centers and computer centers, banking and securities, taxation, communication, postal services, broadcasting and television, public security, transportation, electricity, healthcare, industrial control, and national defense.

Technical parameters

Model HBG - 1KR (S) HBG - 2KR (S) HBG - 3KR (S) HBG - 6KR(S) HBG - 10KR(S)
Phase Single Phase Input and Output Single Phase Input and Output Single Phase Input and Output Single Phase Input and Output Single Phase Input and Output
Capacity 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000 VA / 4800 W 10000 VA / 8000 W
Input          
Input Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage Range 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load 110-300VAC ±3% at 50% load; 176-300 VAC ±3% at 100% load
Frequency Range 40Hz ~ 70 Hz 40Hz ~ 70 Hz 40Hz ~ 70 Hz 40Hz ~ 70 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Power Factor ≥ 0.99@100% load ≥ 0.99@100% load ≥ 0.99@100% load ≥ 0.99@100% load ≥ 0.99@100% load
Output          
Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage Regulation (Battery Mode) ±1% ±1% ±1% ±1% ±1%
Frequency Range (Synchronous Correction Range) 47 ~ 53 Hz or 57 ~ 63 Hz 47 ~ 53 Hz or 57 ~ 63 Hz 47 ~ 53 Hz or 57 ~ 63 Hz 47 ~ 53 Hz or 57 ~ 63 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Frequency Accuracy (Battery Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1 3:1 3:1 3:1 3:1
Harmonic Distortion ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load)
Conversion Time          
AC to DC None None None None 0 ms
Inverter to Bypass 4 ms (Standard Conditions) 4 ms (Standard Conditions) 4 ms (Standard Conditions) 4 ms (Standard Conditions) 0 ms
Waveform (Battery Mode) Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave
Efficiency          
Mains Mode 88% 89% 90% 92% 93%
Battery Mode 83% 87% 88% 90% 91%
Battery          
Standard Unit          
Battery Model 12V / 9AH 12V / 9AH 12V / 9AH 12V / 9AH 12V / 9AH
Quantity (Cells) 2 4 6 16 20
Standard Charging Time - 4 hours to 90% - 9 hours to 90% -
Maximum Charging Current - 1.0A (Max) - Preset:1.0A, Max:2.0A -
Charging Voltage 27.4VDC ±1% 54.7VDC ±1% 82.1VDC ±1% 218.4VDC ±1%
 
273VDC ±1%
 
218.4VDC ±1%
 
273VDC ±1%
-
Long-term Unit          
Battery Model - - Depends on Power Supply Time Depends on Power Supply Time -
Quantity (Cells) 2
 
3
4 6
 
8
16-20 Grain (adjustable) -
Maximum Charging Current - 1.0A,2.0A,4.0A,6.0A - 1.0A, 2.0A, 4.0A, 6.0A (adjustable, 6A only applicable to 16 batteries) -
Charging Voltage 27.4VDC ±1%
 
41.0VDC ±1%
54.7VDC ±1% 82.1VDC ±1%
 
82.1VDC ±1%
109.4VDC±1%
 
218.4VDC ±1% (Based on 16 pieces)
-
Appearance          
LCD or LED Display Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication
Alarm          
Battery Mode Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds
Low Battery Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second
Overload Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second
Error Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep
External Dimensions          
Standard Unit          
Dimensions (W×D×H)mm 310 X 438 X 88 410 X 438 X 88 630 X 438 X 88 host:530 X 438 X 88【2U】
 
battery box:438 X 530 X 668 X 438 X 88【2U】
 
battery box:61
host:580 X 438 X 133【3U】
 
battery box:580 X 438 X 133【3U】
Net Weight (kg) 9.9 16.9 25.6 host:135
 
battery box:61
 
500 X 438 X 88【2U】
 
15
host:18
 
battery box:61
 
580 X 438 X 133【3U】
 
18
Long-term Unit          
Dimensions (W×D×H)mm 310 X 438 X 88 410 X 438 X 88 - - -
Net Weight (kg) 5.5 8.1 8.5 - -
Operating Environment          
Temperature and Humidity Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) Relative Humidity 0-95% and Temperature 0-40°C (No Condensation) Relative Humidity 0-95% and Temperature 0-40°C (No Condensation)
Noise Less than 50dB@ 1m Less than 50dB@ 1m Less than 50dB@ 1m Less than 55dB @ 1m Less than 58dB @ 1m
Control Management          
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMP Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management

*When the UPS is set to constant voltage and frequency mode, the output power will be reduced by 40%. When the output voltage of the UPS is set to 208VAC, the output power will be reduced by 10%.

**When the number of internal batteries is changed to 16-19, the machine will reduce the output according to the following formula: P-PrtiX (N/20x100%).

***If the machine is installed at an altitude exceeding 1000 meters, the output power will decrease by 1% for every 100 meters increase. If there are any changes to the current product specifications, no further notice will be given

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.