HBJ series backup uninterruptible power supply

  • HBJ series backup uninterruptible power supply

Key attributes

Brand Switchgear parts
Model NO. HBJ series backup uninterruptible power supply
Rated frequency 50Hz
Input Voltage 145-280VAC
Capacity 1kVA
Series HBJ

Product descriptions from the supplier

Description

Backup UPS Uninterruptible Power Supply is an economical and practical emergency power supply equipment. Its core uses the "mains priority power supply+battery emergency backup" mode to quickly switch in case of mains power interruption or abnormality, providing short-term stable power to electrical equipment to avoid data loss or equipment damage. It is a basic power supply guarantee solution for daily office, home, and small scenarios.
Core Features
Simple structure, affordable cost, high cost-effectiveness, suitable for emergency power supply needs of ordinary users, without the need for complex installation.
When the mains power is normal, it directly supplies power and charges the built-in battery. After the mains power is interrupted, it switches to battery power in milliseconds, with smooth and seamless switching.
Integrated surge protection and overload protection functions effectively resist power grid interference such as voltage fluctuations and surges.
Compact size, low noise, strong energy efficiency, low standby power consumption, suitable for limited space scenarios such as desktops and small computer rooms.
Applicable scenarios
Suitable for scenarios such as homes, small offices, convenience stores, etc., it mainly provides emergency power supply for electronic devices such as computers, routers, printers, monitoring equipment, and small servers that are sensitive to power outages, ensuring short-term data storage, safe shutdown of devices, or continuous critical operations.

Technical Specifications

Model

HBJ-600VA

HBJ-1000VAM

HBJ-1000VA

HBJ-1500VA

HBJ-2000VA

Capacity

600VA/360W

1000VA/480W

1000VA/720W

1500VA/900W

2000VA/1200W

Input

 

 

 

 

 

Voltage

220VAC

220VAC

220VAC

220VAC

220VAC

AC Mains Input Voltage Range

145-280 VAC

145-280 VAC

145-280 VAC

145-280 VAC

145-280 VAC

Frequency

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

Output

 

 

 

 

 

Voltage Range (Battery Mode)

±10%

±10%

±10%

±10%

±10%

Frequency Range (Battery Mode)

50 Hz±1Hz

50 Hz±1Hz

50 Hz±1Hz

50 Hz±1Hz

50 Hz±1Hz

Transfer Time

Generally 2-6ms, maximum not exceeding 10ms

Waveform (Battery)

Modified sine wave

Battery

 

Battery model & Quantity

12 V7Ah×1

12V9Ah×1

12V7 Ah×2

12V9Ah×2

12V9Ah×2

Battery Charging Time

6 hours charge to 90%

LED Indicators

 

AC Mode

Yellow light

Battery Mode

Yellow light flash

Audible alarm

 

Battery Mode

Alarm beeps every 6 seconds

Low battery

Alarm beeps every 1 second

Overload

Alarm beeps every 0.5 seconds (two beeps per second)

Fault

Alarm beeps continuously

Protection Function

 

Comprehensive Protection

Overload, deep discharge and over-charge protection

Physical Function

 

Dimensions DX WXH(mm)

335×87×143

312×122×195

360×122×195

360×122×195

360×122×195

Weight (kgs)

4.4

6.9

8.4

24.5

25.48

Environment

 

 

 

 

 

Temperature And Humidity

Relative humidity 0-90% and temperature 0-40℃(No-condensing)

Noise

less than 40dB at one meter distance

FAQ
Q: How to maintain the battery of the HBJ series backup UPS and how long is its service life?
A:

Routine maintenance: Perform a full charge-discharge test every 3-6 months (discharge to 50% of the load and then charge for 12 hours) to activate the battery . Avoid long-term overcharging or deep discharge. The battery service life is 3-5 years under normal use; if the backup time is significantly shortened (less than 50% of the initial time), it means the battery is aging and needs to be replaced with the same specification model.

Q: What is the core function and working principle of the HBJ series backup UPS?
A:

Its core function is to provide uninterrupted power supply for critical equipment when the mains power fails. The working principle is: when the mains is normal, it directly supplies power to the load and charges the internal battery at the same time; when the mains is interrupted (such as power outage, voltage fluctuation), it switches to battery power supply within milliseconds, ensuring that the load equipment does not shut down unexpectedly. It also filters mains noise and surges to protect sensitive electronic devices.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.