Key attributes

Brand MV Switchgear Accessories
Model NO. GYM7DC High Voltage Molded Case Circuit Breaker for PV
Rated normal current 320A
Rated lightning impulse voltage 12kV
Series GYM7DC

Product descriptions from the supplier

Description

GYM7DC series DC molded case circuit breakers are suitable for circuits with rated operating voltage up to DC1500V, rated insulation voltage up to 1500V, rated impulse withstand voltage up to 12kV, and rated current of 10A~630A. They can be installed vertically or horizontally and can withstand environments such as humid air, salt spray, oil mist, mold, etc

GYM7DC series DC molded case circuit breaker product features:
1. The GYM7DC series DC plastic shell circuit breaker (hereinafter referred to as the circuit breaker) has a rated working voltage of up to DC1500V, a rated insulation voltage of 1500V, a rated impulse withstand voltage of up to 12kV, and a rated current of 10A~630A.  
2. This circuit breaker can be installed vertically or horizontally.  
3. This circuit breaker product complies with the following standards:
4. IEC 60947-1 and GB/T 14048.1 General Provisions
5. IEC 60947-2 and GB/T 14048.2 Low voltage circuit breakers.

Technical Parameters:

Model

GYM7DC-320

GYM7DC-400/630

GYM7DC-1600

Rated Current

63、80、100、125、140、160、180、200、225、250、315、320

225、250、320、350、400、500、630

800A、1000A、1250A、1500A、1600A

Number of poles

2P

2P

3P

4P

Rated Working Voltage Ue DC

1500

Rated Insulation Voltage Ui(V)

1800

1800

Rated Impulse withstand Voltage UImp

12

12

Power Frequency withstand Voltage(1min)(kV)

3500

3500

Rated Ultimates Short-Circuit Breaking Capacity Icu(V)

DC 1200V

DC 1500V

DC 750V

DC 1000V

DC 750V

DC 1000V

DC 1200V

DC 1500V

Rated Service Short-Circuit Breaking Capacity Ics (kA)

35kA

20kA

85kA

50kA

50kA

30kA

15kA

10kA

Mechanical Life(kA)

4000

Electrical Life(times)

10000

500

Arc Distance(times)

50、0(with arc extinguishing chamber)

100

Basic Dimension W*L*H(mm)

90*215*136

110*275*152

3P:210*340*244 4P:280*340*244

Instantaneous release(mm)

5In or 10In

Reference Ambient Temperature

50℃

FAQ for
Q: What is the difference between the GYM7DC PV High Voltage MCCB and traditional AC circuit breakers?
A:

The core differences are reflected in four aspects: voltage adaptability, arc extinguishing capacity, protection logic and scenario application:

① Voltage adaptability difference: The GYM7DC is specially designed for DC systems, with a rated voltage of up to 1500VDC, no zero-crossing arc extinguishing advantage, and relies on a strong arc extinguishing structure; traditional AC circuit breakers have a rated voltage of mostly 400VAC/690VAC, use the zero-crossing characteristic of AC to extinguish arcs, and cannot adapt to the PV DC high-voltage scenario.

② Arc extinguishing capacity difference: The GYM7DC adopts a multi-grid arc extinguishing chamber + magnetic blow arc extinguishing structure, which can quickly cut off DC arcs with a maximum breaking capacity of 100kA; traditional AC circuit breakers have a simple arc extinguishing chamber structure and insufficient DC breaking capacity, and forced use may lead to continuous arc combustion and equipment explosion.

③ Protection logic difference: Targeting the characteristics of PV systems, the GYM7DC integrates functions such as reverse connection protection and undervoltage tripping, and the overload protection curve can adapt to the power fluctuation of PV modules; traditional AC circuit breakers only have overload and short-circuit protection, without PV-specific protection functions.

④ Scenario application difference: The GYM7DC is suitable for scenarios such as the DC side of PV power stations, the input end of inverters and DC distribution of energy storage systems; traditional AC circuit breakers are suitable for industrial and civil AC distribution systems, and cannot meet the protection needs of PV DC high voltage.

Q: What is the High Voltage Molded Case Circuit Breaker for PV?
A:

The GYM7DC High Voltage Molded Case Circuit Breaker for PV is an electrical switchgear specially designed for high-voltage distribution protection of PV DC systems, with a rated working voltage of up to 1500VDC, a rated current range of 100A~1250A, and a maximum high breaking capacity of 100kA. Integrating core functions including overload protection, short-circuit protection, reverse connection protection and intelligent tripping, this equipment adopts a modular design and corrosion-resistant shell material, suitable for DC-side distribution protection of solar power plants, distributed PV systems and PV energy storage systems. It can be directly matched with PV inverters and combiner boxes to ensure the stable operation of PV systems under complex working conditions.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Rockwill Passes Single-Phase Ground Fault Test for Smart Feeder Terminal
    Rockwill Electric Co., Ltd. has successfully passed the real-scenario single-phase-to-ground fault test conducted by the Wenzhou of China Electric Power Research Institute for its DA-F200-302 hood-type feeder terminal and integrated primary-secondary pole-mounted circuit breakers—ZW20-12/T630-20 and ZW68-12/T630-20—receiving an official qualified test report. This achievement marks Rockwill Electric as a leader in single-phase ground fault detection technology within distribution networks.The DA
    12/25/2025
  • Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
    1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
    12/16/2025
  • Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
    1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
    12/16/2025
  • A Brief Discussion on the Issues of Converting Reclosers into Outdoor Vacuum Circuit Breakers for Use
    The rural power grid transformation plays an important role in reducing rural electricity tariffs and accelerating rural economic development. Recently, the author participated in the design of several small-scale rural power grid transformation projects or conventional substations. In rural power grid substations, conventional 10kV systems mostly adopt 10kV outdoor auto circuit vacuum reclosers.To save investment, we adopted a scheme in the transformation that removes the control unit of the 10
    12/12/2025
  • A Brief Analysis of Automatic Circuit Recloser in Distribution Feeder Automation
    An Automatic Circuit Recloser is a high-voltage switching device with built-in control (it inherently possesses fault current detection, operation sequence control, and execution functions without requiring additional relay protection or operating devices) and protective capabilities. It can automatically detect the current and voltage in its circuit, automatically interrupt fault currents according to inverse-time protection characteristics during faults, and perform multiple reclosures accordi
    12/12/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.