GYAR9-AC-TY-GYL9 Reclosor Automatizatus Intelligentus

  • GYAR9-AC-TY-GYL9 Smart Auto Recloser
  • GYAR9-AC-TY-GYL9 Smart Auto Recloser

Attributa principalia

Marca Switchgear parts
Numerus Modeli GYAR9-AC-TY-GYL9 Reclosor Automatizatus Intelligentus
Votum nominatum AC220V
Frequenta nominata 50/60Hz
Series GYAR9-AC

Descriptiones productorum a fornitori

Descriptio

Series GYAR9 SMART AUTO RECLOSER a IEE-Business offert solutio robustam et adaptabilem pro systematibus electricis in locis industrialibus et commercialibus. Compatibilis cum Dispositivo Residuali de Currente GYL9, augens securitatem et fiduciam.

Tensio Nominata: AC-220V vel DC-48V (ex modello dependet)

Tensio Operativa: 230V AC (70%-125%) vel 24-48V DC

Signalia Controlis: MODBUS-RS485, nodus humidus, vel contactus siccus

Durabilitas: 10,000 operationes electricas et mechanicas

Gradus Protectionis: IP20

Intervallum Temperaturae: -26°C ad +70°C

Producti Highlight:

Modi Controlis Flexibiles: Optiones includunt contactum siccum, contactum humidum, vel controlis RS485 pro integratione sine intermissione.

Protectio Tensionis: Modello GYAR9-AC-UV offert protectio per se recuperabilis supra et infra tensionem ut protegat apparatus.

Automatizatio Recuperationis Defectus: Recuperat per se post defectus temporales, minuens tempus inutilitatis.

Monstratorium Digitalis Monitorii: Monstrat tensionem, numeros commutationum, et conditiones defectuum pro celeri inspectione status.

Securitas Autolocans: Prohibet reclosure repetita durant defectus persistentes, tuebatur systema tuum.

Standard EN 50155, GB/T 24338.4-2018, EN 45545-2, IEC 61373
  Ruber, defectus MCB overcurrent
  Controlis manualis remota aperturae&clausurae inhabilitatum
(inter S2C-RM DC et MCB) 4kV (4.9kV ad niveli maris)
Adaptatio Acti9 Series 1P-4
Temperatura Ambiens -25…+70℃
Commutatio Auto/Manualis Controlis remota aperturae&clausurae disponibilis
Capacitas terminalium signalium auxiliariorum 28-14AWG 1.5mm²
Tempus actionis clausurae < 1s
Longitudo cabli circuiti controlis ≤1500m
Signale controlis MODBUS-RS485 Nodus humidus 230V altus/pulsus signali (optionalis)
Capacitas portantium currentis contactorum auxiliariorum (terminalia 8-9-10) 1CO, minimus operativus currentis 3mA (24VDC) (resistivus) (optionalis)
Capacitas portantium currentis contactorum signalium (terminalia 5-6-7) Maximus operativus currentis 2A (30V DC), 0.5A (125V AC) (optionalis)
Fixatio rail DIN Rail DIN EN 60715 (35 mm)
Monstratorium digitale Tres digiti tensio, numeros commutationum, status defectus
Duratio efficiens signali controlis >400ms
Characteristica Electrica  
Vita electrica 10000 vices, 3 vices/minutum
Gradus periculi secundum EN 45545-2 EN 45545-2 R26 /HL3
Lumen indiciale Viridis, Status normalis
Installatio et Connexio  
Characteristica Mechanica  
Vita mechanica 10000
Positio fixandi Fixatio super rail DIN Ubi libet
Tempus actionis aperturae < 0.5s
Tensio Operativa 230V AC(70%~125%) 24-48V DC (optionalis)
Functio supra&infra tensionem 160-275V ±5V (optionalis)
Capacitas terminalium potentiae et signalium controlis 28-12AWG 2.5mm²
Consumptio potestatis ≤ 1.5VA (staticus); ≤25VA (dynamicus)
Gradus protectionis Ip20
Tensio impulsi nominata Uimp  
Tensio insulationis nominata 400V
Resistentia ad calorem et humiditatem IEC/EN 60068-2-30 28 cyclus (55°C/90-96 % , 25°C/95-100 %)
Protectio autolocans Intra 10s de 3CO / 20s de 4CO / 30s de 6CO, productum autolocabitur et recuperabit per se post 40s.
Resistentia contra shock et vibrationem secundum IEC 61373 categoria 1 – classis A/B – corporis montati
Temperatura conservandae -40…+70℃
Functio temporis Disponibilis (optionalis)
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum