| Marca | Switchgear parts |
| Numerus Modeli | GYAR9-AC-TY-GYL9 Reclosor Automatizatus Intelligentus |
| Votum nominatum | AC220V |
| Frequenta nominata | 50/60Hz |
| Series | GYAR9-AC |
Series GYAR9 SMART AUTO RECLOSER a IEE-Business offert solutio robustam et adaptabilem pro systematibus electricis in locis industrialibus et commercialibus. Compatibilis cum Dispositivo Residuali de Currente GYL9, augens securitatem et fiduciam.
Tensio Nominata: AC-220V vel DC-48V (ex modello dependet)
Tensio Operativa: 230V AC (70%-125%) vel 24-48V DC
Signalia Controlis: MODBUS-RS485, nodus humidus, vel contactus siccus
Durabilitas: 10,000 operationes electricas et mechanicas
Gradus Protectionis: IP20
Intervallum Temperaturae: -26°C ad +70°C
Modi Controlis Flexibiles: Optiones includunt contactum siccum, contactum humidum, vel controlis RS485 pro integratione sine intermissione.
Protectio Tensionis: Modello GYAR9-AC-UV offert protectio per se recuperabilis supra et infra tensionem ut protegat apparatus.
Automatizatio Recuperationis Defectus: Recuperat per se post defectus temporales, minuens tempus inutilitatis.
Monstratorium Digitalis Monitorii: Monstrat tensionem, numeros commutationum, et conditiones defectuum pro celeri inspectione status.
Securitas Autolocans: Prohibet reclosure repetita durant defectus persistentes, tuebatur systema tuum.
| Standard | EN 50155, GB/T 24338.4-2018, EN 45545-2, IEC 61373 |
| Ruber, defectus MCB overcurrent | |
| Controlis manualis remota aperturae&clausurae inhabilitatum | |
| (inter S2C-RM DC et MCB) | 4kV (4.9kV ad niveli maris) |
| Adaptatio | Acti9 Series 1P-4 |
| Temperatura Ambiens | -25…+70℃ |
| Commutatio Auto/Manualis | Controlis remota aperturae&clausurae disponibilis |
| Capacitas terminalium signalium auxiliariorum | 28-14AWG 1.5mm² |
| Tempus actionis clausurae | < 1s |
| Longitudo cabli circuiti controlis | ≤1500m |
| Signale controlis | MODBUS-RS485 Nodus humidus 230V altus/pulsus signali (optionalis) |
| Capacitas portantium currentis contactorum auxiliariorum (terminalia 8-9-10) | 1CO, minimus operativus currentis 3mA (24VDC) (resistivus) (optionalis) |
| Capacitas portantium currentis contactorum signalium (terminalia 5-6-7) | Maximus operativus currentis 2A (30V DC), 0.5A (125V AC) (optionalis) |
| Fixatio rail DIN | Rail DIN EN 60715 (35 mm) |
| Monstratorium digitale | Tres digiti tensio, numeros commutationum, status defectus |
| Duratio efficiens signali controlis | >400ms |
| Characteristica Electrica | |
| Vita electrica | 10000 vices, 3 vices/minutum |
| Gradus periculi secundum EN 45545-2 | EN 45545-2 R26 /HL3 |
| Lumen indiciale | Viridis, Status normalis |
| Installatio et Connexio | |
| Characteristica Mechanica | |
| Vita mechanica | 10000 |
| Positio fixandi | Fixatio super rail DIN Ubi libet |
| Tempus actionis aperturae | < 0.5s |
| Tensio Operativa | 230V AC(70%~125%) 24-48V DC (optionalis) |
| Functio supra&infra tensionem | 160-275V ±5V (optionalis) |
| Capacitas terminalium potentiae et signalium controlis | 28-12AWG 2.5mm² |
| Consumptio potestatis | ≤ 1.5VA (staticus); ≤25VA (dynamicus) |
| Gradus protectionis | Ip20 |
| Tensio impulsi nominata Uimp | |
| Tensio insulationis nominata | 400V |
| Resistentia ad calorem et humiditatem IEC/EN 60068-2-30 | 28 cyclus (55°C/90-96 % , 25°C/95-100 %) |
| Protectio autolocans | Intra 10s de 3CO / 20s de 4CO / 30s de 6CO, productum autolocabitur et recuperabit per se post 40s. |
| Resistentia contra shock et vibrationem secundum IEC 61373 | categoria 1 – classis A/B – corporis montati |
| Temperatura conservandae | -40…+70℃ |
| Functio temporis | Disponibilis (optionalis) |