| ब्रांड | Switchgear parts | 
| मॉडल नंबर | GYAR9-AC-TY-GYL9 स्मार्ट ऑटो रिक्लोजर | 
| निर्धारित वोल्टेज | AC220V | 
| निर्धारित आवृत्ति | 50/60Hz | 
| श्रृंखला | GYAR9-AC | 
GYAR9 SMART AUTO RECLOSER श्रृंखला IEE-Business द्वारा औद्योगिक और व्यापारिक सेटिंग में विद्युत प्रणालियों के लिए एक मजबूत और अनुकूल समाधान प्रदान करती है। GYL9 अवशिष्ट धारा उपकरण के साथ संगत, सुरक्षा और विश्वसनीयता में सुधार करती है।
Rated Voltage: AC-220V or DC-48V (model dependent)
Operating Voltage: 230V AC (70%-125%) or 24-48V DC
Control Signals: MODBUS-RS485, wet node, or dry contact
Durability: 10,000 electrical and mechanical operations
Protection Rating: IP20
Temperature Range: -26°C to +70°C
Flexible Control Modes: Options include dry contact, wet contact, or RS485 control for seamless integration.
Voltage Protection: The GYAR9-AC-UV model offers self-recovering over and under voltage protection to shield equipment.
Fault Recovery Automation: Automatically resets after temporary faults, minimizing downtime.
Digital Monitoring Display: Shows voltage, switching counts, and fault conditions for quick status checks.
Self-Locking Safety: Prevents repeated reclosing during persistent faults, safeguarding your system.
| Standard | EN 50155, GB/T 24338.4-2018, EN 45545-2, IEC 61373 | 
| Red, MCB overcurrent fault | |
| Manual Remote control of opening&closing disabled | |
| (between S2C-RM DC and MCB) | 4kV (4.9kV at sea level) | 
| Adaption | Acti9 Series 1P-4 | 
| Ambient Temperature | -25…+70℃ | 
| Auto/Manual switching | Auto Remote control of opening&closing available | 
| Auxiliary signal terminal wiring capacity | 28-14AWG 1.5mm² | 
| Closing action time | < 1s | 
| Control circuit cable length | ≤1500m | 
| Control signal | MODBUS-RS485 Wet node 230V high level/pulse signal (optional) | 
| Current-carrying capacity of auxiliary contacts (terminals 8-9-10) | 1CO, minimum operating current 3mA (24VDC) (resistive) (optional) | 
| Current-carrying capacity of signaling contacts (terminals 5-6-7) | Maximum operating current 2A (30V DC), 0.5A (125V AC) (optional) | 
| DIN rail mounting | DIN rail EN 60715 (35 mm) | 
| Digital display | 3-digit voltage, switching times, fault status | 
| Effective control signal duration | >400ms | 
| Electrical Characteristics | |
| Electrical life | 10000 times, 3 times/minute | 
| Hazard class according to EN 45545-2 | EN 45545-2 R26 /HL3 | 
| Indicator Light | Green, Normal status | 
| Installation and Wiring | |
| Mechanical Characteristics | |
| Mechanical life | 10000 | 
| Mounting position | Mounting on DIN rail Any position | 
| Opening action time | < 0.5s | 
| Operating Voltage | 230V AC(70%~125%) 24-48V DC(optional) | 
| Over&Under voltage function | 160-275V ±5V (optional) | 
| Power and control signal terminal wiring capacity | 28-12AWG 2.5mm² | 
| Power consumption | ≤ 1.5VA (static); ≤25VA (dynamic) | 
| Protection class | Ip20 | 
| Rated Impulse Withstand Voltage Uimp | |
| Rated insulation voltage | 400V | 
| Resistance to heat and humidity IEC/EN 60068-2-30 | 28 cycles (55°C/90-96 % , 25°C/95-100 %) | 
| Self-locking protection | Within 10s of 3CO / 20s of 4CO / 30s of 6CO, the product will self-lock and recover automatically after 40s. | 
| Shock and vibration resistance According to IEC 61373 | category 1 – class A/B – body mounted | 
| Storage Temperature | -40…+70℃ | 