| Brand | ROCKWILL |
| Series | RMR,KYN28 |

ROCKWILL Gas Insulated Switchgear (GIS / C-GIS) for primary distribution is a modular, metal-enclosed, hermetically sealed medium-voltage switchgear assembly designed for critical primary distribution networks. All live conductive components—including main busbars, circuit breaker, disconnectors, earthing switches, current transformers and voltage transformers—are enclosed within independent stainless steel gas compartments and insulated by SF6 gas.
This GIS integrates ROCKWILL’s mature SF6 auto-puffer circuit breaker unit, which is the same breaker platform used in our standalone indoor SF6 circuit breaker. Customers can select either fixed type or draw-out handcart type breaker configuration. The breaker performs rated load switching, no-load bus transfer and short-circuit fault current interruption reliably.
The gas-tight encapsulated design reduces overall footprint and provides strong resistance against dust, high humidity, salt fog, industrial corrosive gas and pollution. Its modular bay architecture supports flexible single-bus, sectionalised single-bus and double-bus schemes. New feeder bays can be added at a later stage without redesigning the entire substation layout, making it suitable for phased substation expansion.
ROCKWILL primary distribution GIS is fully type tested in accredited laboratories. It carries CE marking, complies with the IEC 62271 product series and is manufactured under an ISO9001 quality management system. Standard warranty is 3 years after shipment, with commercial and after-sales terms negotiable for different regional markets and EPC projects.

| Item | Parameter |
|---|---|
| Rated voltage | 12kV / 17.5kV / 24kV / 36kV / 40.5kV |
| Rated frequency | 50Hz / 60Hz |
| Rated busbar continuous current | 630A, 1250A, 2000A, 2500A, 3150A |
| Rated short-circuit breaking current | 20kA, 25kA, 31.5kA, 40kA |
| Rated short-time withstand current (3s) | 20kA, 25kA, 31.5kA, 40kA |
| Rated peak withstand current | 50kA, 63kA, 80kA, 100kA |
| Interruption device | ROCKWILL SF6 auto-puffer circuit breaker (fixed / draw-out handcart) |
| Insulation & arc quenching medium | SF6 gas |
| Main tank material | Stainless steel, fully welded gas-tight enclosure |
| Internal arc classification | IAC-AFL (higher class available on request) |
| Service continuity category | LSC2A |
| Auxiliary supply | AC/DC 110V, 220V optional |
| Applicable standards | IEC 62271-1, IEC 62271-100, IEC 62271-200 |
| Certification | CE certificate, IEC type test report, ISO9001 |
| Installation type | Indoor |
| Ambient operating temperature | -25°C ~ +40°C |
| Standard altitude rating | ≤2000 m above sea level |
| Warranty | 3 years after shipment, regional terms negotiable |
The standard ROCKWILL GIS is designed for indoor installation under normal environmental conditions. For projects located in coastal salt-spray zones, industrial parks with corrosive gas or high-pollution areas, ROCKWILL can provide enhanced anti-corrosion treatment for the outer enclosure and auxiliary components. For sites above 2000 m altitude, insulation coordination and gas pressure settings can be adjusted to meet the application requirements.
ROCKWILL GIS units are manufactured under an ISO9001 quality management system. Each bay undergoes factory routine tests before shipment, including gas tightness verification, partial discharge measurement, protection relay testing, control circuit continuity checks and mechanical interlock function validation.
Type tests are carried out in independent accredited laboratories according to IEC 62271 series standards, covering dielectric tests, temperature rise, short-circuit making and breaking, internal arc resistance, mechanical endurance and SF6 gas tightness. ROCKWILL provides CE documentation, IEC type test reports and ISO9001 certificates to support customer procurement, engineering review and project acceptance.
ROCKWILL primary distribution GIS is supplied with a standard warranty of 3 years after shipment. Within the warranty period, ROCKWILL provides technical support and spare parts service for manufacturing defects. The warranty does not cover damage caused by improper operation, unauthorised repair, abnormal system conditions or transportation accidents. Specific warranty terms, spare part agreements and on-site service scope can be negotiated for different regional markets and project conditions.

ROCKWILL GIS is equipped with our self-developed SF6 auto-puffer circuit breaker, which is the same proven platform used in ROCKWILL’s standalone indoor SF6 circuit breaker. During the opening operation, the moving contact drives the puffer cylinder to compress SF6 gas. The high-pressure SF6 gas is then blown into the arc zone, cooling and de-ionising the arc rapidly so that the fault current is interrupted at current zero. This design enables reliable load switching and short-circuit interruption.
The standard ROCKWILL GIS covers rated voltages of 12kV, 17.5kV, 24kV, 36kV and 40.5kV. The rated continuous busbar current ranges from 630A to 3150A, and the short-circuit breaking current options include 20kA, 25kA, 31.5kA and 40kA for 3 seconds. ROCKWILL can select appropriate current transformers, voltage transformers and protection settings based on the system short-circuit level and protection requirements.
The standard warranty period is 3 years from the date of shipment. During this period, ROCKWILL provides factory technical support, spare part supply and remote fault diagnosis. For EPC projects, turnkey contracts and long-term regional cooperation projects, warranty duration, on-site commissioning services and spare part packages can be negotiated separately to match project requirements.
The standard unit is rated for altitudes up to 2000 m and ambient temperatures from -25°C to +40°C. For high-altitude applications above 2000 m, ROCKWILL adjusts the insulation margin and optimises the SF6 gas pressure settings. For low-temperature environments, temperature-compensated density monitors and anti-condensation heaters can be provided. For coastal or corrosive industrial areas, enhanced anti-corrosion coating and special material fasteners are available.
ROCKWILL applies strict quality control throughout the manufacturing process, from incoming material inspection to final routine testing. Each GIS bay is subjected to SF6 gas tightness testing, partial discharge measurement, protection relay testing, mechanical operation checks and interlock verification. Type tests are performed by accredited third-party laboratories in accordance with IEC 62271-1, IEC 62271-100 and IEC 62271-200.