SF6 Gas-insulated RMU Ring Main Unit for distribution networks-12kV

Add us on Google
  • SF6 Gas-insulated RMU Ring Main Unit for distribution networks-12kV

Key attributes

Brand ROCKWILL
Series RMR
Rated Voltage 12 kV
Rated Short-Circuit Breaking Current 20 kA / 25 kA
Lightning Impulse Withstand Voltage 75 kV
Rated Frequency 50 Hz / 60 Hz
Description

This SF6 gas insulated ring main unit, fully complying with IEC 62271-200 and IEC 62271-103 international standards.
All live conductive components are encapsulated in airtight 304 stainless steel gas tank, with SF6 acting as insulation and arc-extinguishing medium. The equipment adopts independent three-compartment layout (busbar compartment, gas switch compartment, cable compartment), equipped with integrated three-position load switch and earthing switch.

Standard C/F/V functional modules can be freely combined to form ring, radial and sectionalized medium voltage distribution networks.
The compact vertical split cabinet structure matches the physical picture, suitable for indoor box substations, urban narrow distribution stations and commercial power distribution projects, realizing reliable switching, fault isolation and overcurrent protection for 12kV grids.

Product Showcase Video

Core Standard Features

  • Reliable SF6 Hermetic Insulation:Fully welded stainless steel gas tank with annual SF6 leakage rate ≤0.03%, equipped with gas density monitor for real-time internal pressure monitoring, avoiding insulation breakdown caused by gas loss.

  • Modular Three-Compartment Safety Layout:Independent partition design for busbar, switching and cable chambers, with optional IAC internal arc resistance structure to meet IEC anti-arc safety requirements.

  • Complete 5-Way Mechanical & Electrical Interlock:Standard five-prevention interlock mechanism prevents misoperation of switch, earthing device and cabinet door, fully conforming to IEC safety operation specifications.

  • Maintenance-Free Long Service Life:Sealed gas chamber isolates dust, moisture and corrosive gas; 20-year design life without regular gas refilling, mechanical operation life up to 5,000 cycles.

  • Wide Global Grid Compatibility:Supports 50Hz & 60Hz dual frequency, compatible with overhead cable incoming/outgoing, transformer protection and distributed new energy power supply systems.

  • Intelligent Expansion Reserved:Reserved installation space for DTU remote monitoring unit, CT/PT measuring components for feeder automation upgrade.

Technical Specification

Rated Voltage 12 kV
Rated Frequency 50 Hz / 60 Hz
Rated Continuous Current 630 A
Rated Short-Time Withstand Current (3 s) 20 kA / 25 kA
Rated Short-Circuit Breaking Current 20 kA / 25 kA
Insulation Medium SF6 Gas
Main Switch Type Three-position SF6 Load Break Switch
Power Frequency Withstand Voltage 42 kV
Lightning Impulse Withstand Voltage 75 kV
SF6 Annual Leakage Rate ≤0.03 %
Internal Arc Classification (IAC) IAC A FLR 20 kA (optional)
Mechanical Operation Life ≥5,000 cycles
Rated Contact & Winding Temperature Rise 55 K
Insulation Class Class A
Protection Degree IP67 (Hermetic SF6 Gas Tank), IP4X (Outer Cabinet)
Ambient Operating Temperature -25 ℃ ~ +40 ℃
Max Installation Altitude ≤2000 m
Relative Humidity Daily average ≤95%, Monthly average ≤90%
Design Service Life 20 years
Compliance Standards IEC 62271-200, IEC 62271-103

Application Scenarios

  • Urban residential ring distribution networks

  • Industrial parks, mining and manufacturing power supply

  • Shopping malls, high-rise buildings and commercial complexes

  • Photovoltaic & wind power new energy collection stations

  • Indoor compact kiosk substations and box transformers

  • Municipal public infrastructure medium voltage power distribution

Case Studies - SF6 Gas-insulated

Documentation Resource Library SF6 Gas-insulated

Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Frequently asked questions

Independent three-compartment layout: busbar compartment, gas switch compartment, cable compartment. Optional IAC internal arc resistance for IEC anti-arc safety.

Yes. Reserved installation space for DTU remote monitoring unit and CT/PT measuring components for feeder automation upgrade.

Yes. Compact vertical split cabinet structure matches standard dimensions for indoor box substations, urban narrow distribution stations, and commercial projects.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register